改进辐射剂量测量用石墨量热计的计量性能

Q4 Engineering
Susy Toma , Massimo Pinto , Fausto Arpino , Domenico Capriglione
{"title":"改进辐射剂量测量用石墨量热计的计量性能","authors":"Susy Toma ,&nbsp;Massimo Pinto ,&nbsp;Fausto Arpino ,&nbsp;Domenico Capriglione","doi":"10.1016/j.measen.2024.101426","DOIUrl":null,"url":null,"abstract":"<div><div>This paper summarizes the progress on enhancing the metrological performance of the Italian national standard of absorbed dose to water, a graphite calorimeter, in a water phantom, for radiation dosimetry measurements designed and built at ENEA-INMRI, National Institute of Ionizing Radiation Metrology in Italy. This constitutes the first application of graphite calorimetry in the mid-energy x-ray region, with generating voltages from 180 to 250 kV, in an effort to improve the measurement accuracy of the quantity absorbed dose to water, <em>D</em><sub><em>w</em></sub>. The design of the Italian primary standard for absorbed dose to water <em>D</em><sub><em>w</em></sub> is shown, together with a wide experimental campaign aimed at identifying the optimized instrument settings which allows improving the measurement repeatability and reducing the overall uncertainty budget.</div></div>","PeriodicalId":34311,"journal":{"name":"Measurement Sensors","volume":"38 ","pages":"Article 101426"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Towards improving the metrological performance of a graphite calorimeter for radiation dosimetry measurements\",\"authors\":\"Susy Toma ,&nbsp;Massimo Pinto ,&nbsp;Fausto Arpino ,&nbsp;Domenico Capriglione\",\"doi\":\"10.1016/j.measen.2024.101426\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This paper summarizes the progress on enhancing the metrological performance of the Italian national standard of absorbed dose to water, a graphite calorimeter, in a water phantom, for radiation dosimetry measurements designed and built at ENEA-INMRI, National Institute of Ionizing Radiation Metrology in Italy. This constitutes the first application of graphite calorimetry in the mid-energy x-ray region, with generating voltages from 180 to 250 kV, in an effort to improve the measurement accuracy of the quantity absorbed dose to water, <em>D</em><sub><em>w</em></sub>. The design of the Italian primary standard for absorbed dose to water <em>D</em><sub><em>w</em></sub> is shown, together with a wide experimental campaign aimed at identifying the optimized instrument settings which allows improving the measurement repeatability and reducing the overall uncertainty budget.</div></div>\",\"PeriodicalId\":34311,\"journal\":{\"name\":\"Measurement Sensors\",\"volume\":\"38 \",\"pages\":\"Article 101426\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2665917424004021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Sensors","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2665917424004021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

本文综述了意大利国家电离辐射计量研究所(ENEA-INMRI)研制的水模式石墨量热计在提高意大利国家标准水吸收剂量计量性能方面的进展。这是石墨量热法在产生180 ~ 250千伏电压的中能x射线区域的首次应用,旨在提高对水的吸收剂量Dw的测量精度。图中展示了意大利吸收剂量对水Dw主要标准的设计,以及旨在确定优化仪器设置的广泛实验活动,这些设置可以提高测量可重复性并减少总体不确定度预算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Towards improving the metrological performance of a graphite calorimeter for radiation dosimetry measurements
This paper summarizes the progress on enhancing the metrological performance of the Italian national standard of absorbed dose to water, a graphite calorimeter, in a water phantom, for radiation dosimetry measurements designed and built at ENEA-INMRI, National Institute of Ionizing Radiation Metrology in Italy. This constitutes the first application of graphite calorimetry in the mid-energy x-ray region, with generating voltages from 180 to 250 kV, in an effort to improve the measurement accuracy of the quantity absorbed dose to water, Dw. The design of the Italian primary standard for absorbed dose to water Dw is shown, together with a wide experimental campaign aimed at identifying the optimized instrument settings which allows improving the measurement repeatability and reducing the overall uncertainty budget.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Measurement Sensors
Measurement Sensors Engineering-Industrial and Manufacturing Engineering
CiteScore
3.10
自引率
0.00%
发文量
184
审稿时长
56 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信