{"title":"一种超稳定音频电力校准器的实现","authors":"You Li ,&nbsp;Wu Kang ,&nbsp;Wang Shuqiang ,&nbsp;Li Jingjing","doi":"10.1016/j.measen.2024.101431","DOIUrl":null,"url":null,"abstract":"<div><div>The article introduce the design and implementation of an ultra-stable audio frequency electrical power calibrator, with voltage range up to 1 kV, current range up to 20A and frequency range from 20 Hz to 20 kHz. The 1 hour stability of its output power can reach to 25 ppm. It has good potential application for precision calibration of audio frequency power meters, energy meters, amplifiers and transducers.</div></div>","PeriodicalId":34311,"journal":{"name":"Measurement Sensors","volume":"38 ","pages":"Article 101431"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Realization of an ultra-stable audio frequency electrical power calibrator\",\"authors\":\"You Li ,&nbsp;Wu Kang ,&nbsp;Wang Shuqiang ,&nbsp;Li Jingjing\",\"doi\":\"10.1016/j.measen.2024.101431\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The article introduce the design and implementation of an ultra-stable audio frequency electrical power calibrator, with voltage range up to 1 kV, current range up to 20A and frequency range from 20 Hz to 20 kHz. The 1 hour stability of its output power can reach to 25 ppm. It has good potential application for precision calibration of audio frequency power meters, energy meters, amplifiers and transducers.</div></div>\",\"PeriodicalId\":34311,\"journal\":{\"name\":\"Measurement Sensors\",\"volume\":\"38 \",\"pages\":\"Article 101431\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2665917424004070\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Sensors","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2665917424004070","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种电压范围为1kv、电流范围为20A、频率范围为20hz ~ 20khz的超稳定音频电力校准器的设计与实现。其输出功率1小时稳定性可达25ppm。它在音频功率表、电能表、放大器和换能器的精密校准中具有良好的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Realization of an ultra-stable audio frequency electrical power calibrator
The article introduce the design and implementation of an ultra-stable audio frequency electrical power calibrator, with voltage range up to 1 kV, current range up to 20A and frequency range from 20 Hz to 20 kHz. The 1 hour stability of its output power can reach to 25 ppm. It has good potential application for precision calibration of audio frequency power meters, energy meters, amplifiers and transducers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Measurement Sensors
Measurement Sensors Engineering-Industrial and Manufacturing Engineering
CiteScore
3.10
自引率
0.00%
发文量
184
审稿时长
56 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信