Oleh Velychko, Vasyl Dovhan, Denys Nikitenko, Jaroslav Brezytskyi
{"title":"高精度电阻测量的长期漂移评价","authors":"Oleh Velychko, Vasyl Dovhan, Denys Nikitenko, Jaroslav Brezytskyi","doi":"10.1016/j.measen.2024.101430","DOIUrl":null,"url":null,"abstract":"<div><div>The influence of long-time drift of measure on calibration emphasizes the importance of careful monitoring of their metrological characteristics. If drift is not accounted for or corrected, it can lead to failure to calibrate other measuring instruments correctly. The results of evaluation of long-term drift of four high-resistance precision measures with nominal values of 1 MΩ, 10 MΩ, 100 MΩ and 1000 MΩ using polynomial regression of 1-3 orders are presented. Measures have historical calibration data from 1992 to 2023. Sufficient adequacy has been achieved in the description of drift lines for all high-resistance measures. The measurement uncertainties of calibration of a high-resistance measure are evaluated with values from 6 ppm to 9 ppm.</div></div>","PeriodicalId":34311,"journal":{"name":"Measurement Sensors","volume":"38 ","pages":"Article 101430"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the long-term drift of high precision resistance measures\",\"authors\":\"Oleh Velychko, Vasyl Dovhan, Denys Nikitenko, Jaroslav Brezytskyi\",\"doi\":\"10.1016/j.measen.2024.101430\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The influence of long-time drift of measure on calibration emphasizes the importance of careful monitoring of their metrological characteristics. If drift is not accounted for or corrected, it can lead to failure to calibrate other measuring instruments correctly. The results of evaluation of long-term drift of four high-resistance precision measures with nominal values of 1 MΩ, 10 MΩ, 100 MΩ and 1000 MΩ using polynomial regression of 1-3 orders are presented. Measures have historical calibration data from 1992 to 2023. Sufficient adequacy has been achieved in the description of drift lines for all high-resistance measures. The measurement uncertainties of calibration of a high-resistance measure are evaluated with values from 6 ppm to 9 ppm.</div></div>\",\"PeriodicalId\":34311,\"journal\":{\"name\":\"Measurement Sensors\",\"volume\":\"38 \",\"pages\":\"Article 101430\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2665917424004069\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Sensors","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2665917424004069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
Evaluation of the long-term drift of high precision resistance measures
The influence of long-time drift of measure on calibration emphasizes the importance of careful monitoring of their metrological characteristics. If drift is not accounted for or corrected, it can lead to failure to calibrate other measuring instruments correctly. The results of evaluation of long-term drift of four high-resistance precision measures with nominal values of 1 MΩ, 10 MΩ, 100 MΩ and 1000 MΩ using polynomial regression of 1-3 orders are presented. Measures have historical calibration data from 1992 to 2023. Sufficient adequacy has been achieved in the description of drift lines for all high-resistance measures. The measurement uncertainties of calibration of a high-resistance measure are evaluated with values from 6 ppm to 9 ppm.