{"title":"患者对人工智能-临床医生差异的反应:基于网络的随机实验。","authors":"Farrah Madanay, Laura S O'Donohue, Brian J Zikmund-Fisher","doi":"10.2196/68823","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>As the US Food and Drug Administration (FDA)-approved use of artificial intelligence (AI) for medical imaging rises, radiologists are increasingly integrating AI into their clinical practices. In lung cancer screening, diagnostic AI offers a second set of eyes with the potential to detect cancer earlier than human radiologists. Despite AI's promise, a potential problem with its integration is the erosion of patient confidence in clinician expertise when there is a discrepancy between the radiologist's and the AI's interpretation of the imaging findings.</p><p><strong>Objective: </strong>We examined how discrepancies between AI-derived recommendations and radiologists' recommendations affect patients' agreement with radiologists' recommendations and satisfaction with their radiologists. We also analyzed how patients' medical maximizing-minimizing preferences moderate these relationships.</p><p><strong>Methods: </strong>We conducted a randomized, between-subjects experiment with 1606 US adult participants. Assuming the role of patients, participants imagined undergoing a low-dose computerized tomography scan for lung cancer screening and receiving results and recommendations from (1) a radiologist only, (2) AI and a radiologist in agreement, (3) a radiologist who recommended more testing than AI (ie, radiologist overcalled AI), or (4) a radiologist who recommended less testing than AI (ie, radiologist undercalled AI). Participants rated the radiologist on three criteria: agreement with the radiologist's recommendation, how likely they would be to recommend the radiologist to family and friends, and how good of a provider they perceived the radiologist to be. We measured medical maximizing-minimizing preferences and categorized participants as maximizers (ie, those who seek aggressive intervention), minimizers (ie, those who prefer no or passive intervention), and neutrals (ie, those in the middle).</p><p><strong>Results: </strong>Participants' agreement with the radiologist's recommendation was significantly lower when the radiologist undercalled AI (mean 4.01, SE 0.07, P<.001) than in the other 3 conditions, with no significant differences among them (radiologist overcalled AI [mean 4.63, SE 0.06], agreed with AI [mean 4.55, SE 0.07], or had no AI [mean 4.57, SE 0.06]). Similarly, participants were least likely to recommend (P<.001) and positively rate (P<.001) the radiologist who undercalled AI, with no significant differences among the other conditions. Maximizers agreed with the radiologist who overcalled AI (β=0.82, SE 0.14; P<.001) and disagreed with the radiologist who undercalled AI (β=-0.47, SE 0.14; P=.001). However, whereas minimizers disagreed with the radiologist who overcalled AI (β=-0.43, SE 0.18, P=.02), they did not significantly agree with the radiologist who undercalled AI (β=0.14, SE 0.17, P=.41).</p><p><strong>Conclusions: </strong>Radiologists who recommend less testing than AI may face decreased patient confidence in their expertise, but they may not face this same penalty for giving more aggressive recommendations than AI. Patients' reactions may depend in part on whether their general preferences to maximize or minimize align with the radiologists' recommendations. Future research should test communication strategies for radiologists' disclosure of AI discrepancies to patients.</p>","PeriodicalId":16337,"journal":{"name":"Journal of Medical Internet Research","volume":"27 ","pages":"e68823"},"PeriodicalIF":5.8000,"publicationDate":"2025-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12141964/pdf/","citationCount":"0","resultStr":"{\"title\":\"Patient Reactions to Artificial Intelligence-Clinician Discrepancies: Web-Based Randomized Experiment.\",\"authors\":\"Farrah Madanay, Laura S O'Donohue, Brian J Zikmund-Fisher\",\"doi\":\"10.2196/68823\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>As the US Food and Drug Administration (FDA)-approved use of artificial intelligence (AI) for medical imaging rises, radiologists are increasingly integrating AI into their clinical practices. In lung cancer screening, diagnostic AI offers a second set of eyes with the potential to detect cancer earlier than human radiologists. Despite AI's promise, a potential problem with its integration is the erosion of patient confidence in clinician expertise when there is a discrepancy between the radiologist's and the AI's interpretation of the imaging findings.</p><p><strong>Objective: </strong>We examined how discrepancies between AI-derived recommendations and radiologists' recommendations affect patients' agreement with radiologists' recommendations and satisfaction with their radiologists. We also analyzed how patients' medical maximizing-minimizing preferences moderate these relationships.</p><p><strong>Methods: </strong>We conducted a randomized, between-subjects experiment with 1606 US adult participants. Assuming the role of patients, participants imagined undergoing a low-dose computerized tomography scan for lung cancer screening and receiving results and recommendations from (1) a radiologist only, (2) AI and a radiologist in agreement, (3) a radiologist who recommended more testing than AI (ie, radiologist overcalled AI), or (4) a radiologist who recommended less testing than AI (ie, radiologist undercalled AI). Participants rated the radiologist on three criteria: agreement with the radiologist's recommendation, how likely they would be to recommend the radiologist to family and friends, and how good of a provider they perceived the radiologist to be. We measured medical maximizing-minimizing preferences and categorized participants as maximizers (ie, those who seek aggressive intervention), minimizers (ie, those who prefer no or passive intervention), and neutrals (ie, those in the middle).</p><p><strong>Results: </strong>Participants' agreement with the radiologist's recommendation was significantly lower when the radiologist undercalled AI (mean 4.01, SE 0.07, P<.001) than in the other 3 conditions, with no significant differences among them (radiologist overcalled AI [mean 4.63, SE 0.06], agreed with AI [mean 4.55, SE 0.07], or had no AI [mean 4.57, SE 0.06]). Similarly, participants were least likely to recommend (P<.001) and positively rate (P<.001) the radiologist who undercalled AI, with no significant differences among the other conditions. Maximizers agreed with the radiologist who overcalled AI (β=0.82, SE 0.14; P<.001) and disagreed with the radiologist who undercalled AI (β=-0.47, SE 0.14; P=.001). However, whereas minimizers disagreed with the radiologist who overcalled AI (β=-0.43, SE 0.18, P=.02), they did not significantly agree with the radiologist who undercalled AI (β=0.14, SE 0.17, P=.41).</p><p><strong>Conclusions: </strong>Radiologists who recommend less testing than AI may face decreased patient confidence in their expertise, but they may not face this same penalty for giving more aggressive recommendations than AI. Patients' reactions may depend in part on whether their general preferences to maximize or minimize align with the radiologists' recommendations. Future research should test communication strategies for radiologists' disclosure of AI discrepancies to patients.</p>\",\"PeriodicalId\":16337,\"journal\":{\"name\":\"Journal of Medical Internet Research\",\"volume\":\"27 \",\"pages\":\"e68823\"},\"PeriodicalIF\":5.8000,\"publicationDate\":\"2025-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12141964/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Internet Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2196/68823\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Internet Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2196/68823","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
Patient Reactions to Artificial Intelligence-Clinician Discrepancies: Web-Based Randomized Experiment.
Background: As the US Food and Drug Administration (FDA)-approved use of artificial intelligence (AI) for medical imaging rises, radiologists are increasingly integrating AI into their clinical practices. In lung cancer screening, diagnostic AI offers a second set of eyes with the potential to detect cancer earlier than human radiologists. Despite AI's promise, a potential problem with its integration is the erosion of patient confidence in clinician expertise when there is a discrepancy between the radiologist's and the AI's interpretation of the imaging findings.
Objective: We examined how discrepancies between AI-derived recommendations and radiologists' recommendations affect patients' agreement with radiologists' recommendations and satisfaction with their radiologists. We also analyzed how patients' medical maximizing-minimizing preferences moderate these relationships.
Methods: We conducted a randomized, between-subjects experiment with 1606 US adult participants. Assuming the role of patients, participants imagined undergoing a low-dose computerized tomography scan for lung cancer screening and receiving results and recommendations from (1) a radiologist only, (2) AI and a radiologist in agreement, (3) a radiologist who recommended more testing than AI (ie, radiologist overcalled AI), or (4) a radiologist who recommended less testing than AI (ie, radiologist undercalled AI). Participants rated the radiologist on three criteria: agreement with the radiologist's recommendation, how likely they would be to recommend the radiologist to family and friends, and how good of a provider they perceived the radiologist to be. We measured medical maximizing-minimizing preferences and categorized participants as maximizers (ie, those who seek aggressive intervention), minimizers (ie, those who prefer no or passive intervention), and neutrals (ie, those in the middle).
Results: Participants' agreement with the radiologist's recommendation was significantly lower when the radiologist undercalled AI (mean 4.01, SE 0.07, P<.001) than in the other 3 conditions, with no significant differences among them (radiologist overcalled AI [mean 4.63, SE 0.06], agreed with AI [mean 4.55, SE 0.07], or had no AI [mean 4.57, SE 0.06]). Similarly, participants were least likely to recommend (P<.001) and positively rate (P<.001) the radiologist who undercalled AI, with no significant differences among the other conditions. Maximizers agreed with the radiologist who overcalled AI (β=0.82, SE 0.14; P<.001) and disagreed with the radiologist who undercalled AI (β=-0.47, SE 0.14; P=.001). However, whereas minimizers disagreed with the radiologist who overcalled AI (β=-0.43, SE 0.18, P=.02), they did not significantly agree with the radiologist who undercalled AI (β=0.14, SE 0.17, P=.41).
Conclusions: Radiologists who recommend less testing than AI may face decreased patient confidence in their expertise, but they may not face this same penalty for giving more aggressive recommendations than AI. Patients' reactions may depend in part on whether their general preferences to maximize or minimize align with the radiologists' recommendations. Future research should test communication strategies for radiologists' disclosure of AI discrepancies to patients.