[中国国家人体生物监测项目化学污染物定向定量分析质量控制策略]。

Yan-Wei Yang, Xu Zhang, Xiao Lin, Qi Sun, Hui Fu, Yi-Fu Lu, Tian Qiu, Zhuo-Na Zhang, Lin-Na Xie, Hai-Jing Zhang, Miao Zhang, Xiao-Jian Hu, Ying-Li Qu, Feng Zhao, Yue-Bin Lyu, Ying Zhu, Xiao-Ming Shi
{"title":"[中国国家人体生物监测项目化学污染物定向定量分析质量控制策略]。","authors":"Yan-Wei Yang, Xu Zhang, Xiao Lin, Qi Sun, Hui Fu, Yi-Fu Lu, Tian Qiu, Zhuo-Na Zhang, Lin-Na Xie, Hai-Jing Zhang, Miao Zhang, Xiao-Jian Hu, Ying-Li Qu, Feng Zhao, Yue-Bin Lyu, Ying Zhu, Xiao-Ming Shi","doi":"10.3724/SP.J.1123.2024.11022","DOIUrl":null,"url":null,"abstract":"<p><p>The China National Human Biomonitoring Program (CNHBP) was launched in 2016. The program aims to obtain representative exposure data of environmental pollutants in the general population by carrying out field epidemiological surveys of Chinese population and monitoring of environmental pollutants in human biological tissues. This work will provide a scientific basis for the government to formulate environmental pollution prevention and control policies. One of the objectives of human biomonitoring is to provide accurate and comparable data of chemical pollutants in human biological samples. Multi-dimensional quality control measures are implemented for the targeted quantitative analysis of chemical pollutants from the analysis method, experimental blank and analysis processes. The quality control procedures are divided into two stages: (1) focusing on the verification of biomonitoring analysis method, blank screening and control in the pre-detection stage; (2) the quality control of the large-scale sample analysis process in the detection stage. Analysis methods used in CNHBP need to be validated to evaluate the performance and practicability, with emphasis on method detection limit (MDL) and method quantification limit (MQL), matrix effects, stability, and residue and dilution. Blank screening procedures are required for all monitoring indicators to identify, eliminate or reduce blank interference, and the blank value of each batch should be less than the MDL. The laboratory adopts a combination of internal and external quality control measures, the measures mainly include: (1) method validation and detection process of the 10 types of monitoring indicators all used biological matrix reference materials produced by the National Institute of Standards and Technology (NIST), European Reference Materials (ERM) and China Center for Reference Materials, to ensure the accuracy and traceability of the methods; (2) commercial quality control samples and internal quality control samples were used to evaluate the stability of the testing process for the 15 types of monitoring indicators; (3) a total of 60 monitoring indicators of the nine categories participated in the German external quality assessment scheme for analyses in biological materials (G-EQUAS) and achieved satisfactory results; (4) 15 types of monitoring indicators were tested with blind samples. Overall, multi-dimensional quality control measures provide professional support for generating high-quality biomonitoring data.</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"43 6","pages":"559-570"},"PeriodicalIF":0.0000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12093211/pdf/","citationCount":"0","resultStr":"{\"title\":\"[Quality control strategy for targeted quantitative analysis of chemical pollutants in China National Human Biomonitoring Program].\",\"authors\":\"Yan-Wei Yang, Xu Zhang, Xiao Lin, Qi Sun, Hui Fu, Yi-Fu Lu, Tian Qiu, Zhuo-Na Zhang, Lin-Na Xie, Hai-Jing Zhang, Miao Zhang, Xiao-Jian Hu, Ying-Li Qu, Feng Zhao, Yue-Bin Lyu, Ying Zhu, Xiao-Ming Shi\",\"doi\":\"10.3724/SP.J.1123.2024.11022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The China National Human Biomonitoring Program (CNHBP) was launched in 2016. The program aims to obtain representative exposure data of environmental pollutants in the general population by carrying out field epidemiological surveys of Chinese population and monitoring of environmental pollutants in human biological tissues. This work will provide a scientific basis for the government to formulate environmental pollution prevention and control policies. One of the objectives of human biomonitoring is to provide accurate and comparable data of chemical pollutants in human biological samples. Multi-dimensional quality control measures are implemented for the targeted quantitative analysis of chemical pollutants from the analysis method, experimental blank and analysis processes. The quality control procedures are divided into two stages: (1) focusing on the verification of biomonitoring analysis method, blank screening and control in the pre-detection stage; (2) the quality control of the large-scale sample analysis process in the detection stage. Analysis methods used in CNHBP need to be validated to evaluate the performance and practicability, with emphasis on method detection limit (MDL) and method quantification limit (MQL), matrix effects, stability, and residue and dilution. Blank screening procedures are required for all monitoring indicators to identify, eliminate or reduce blank interference, and the blank value of each batch should be less than the MDL. The laboratory adopts a combination of internal and external quality control measures, the measures mainly include: (1) method validation and detection process of the 10 types of monitoring indicators all used biological matrix reference materials produced by the National Institute of Standards and Technology (NIST), European Reference Materials (ERM) and China Center for Reference Materials, to ensure the accuracy and traceability of the methods; (2) commercial quality control samples and internal quality control samples were used to evaluate the stability of the testing process for the 15 types of monitoring indicators; (3) a total of 60 monitoring indicators of the nine categories participated in the German external quality assessment scheme for analyses in biological materials (G-EQUAS) and achieved satisfactory results; (4) 15 types of monitoring indicators were tested with blind samples. Overall, multi-dimensional quality control measures provide professional support for generating high-quality biomonitoring data.</p>\",\"PeriodicalId\":101336,\"journal\":{\"name\":\"Se pu = Chinese journal of chromatography\",\"volume\":\"43 6\",\"pages\":\"559-570\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12093211/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Se pu = Chinese journal of chromatography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3724/SP.J.1123.2024.11022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2024.11022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

中国国家人体生物监测计划(CNHBP)于2016年启动。本项目旨在通过对中国人口进行实地流行病学调查和对人体生物组织中环境污染物的监测,获得具有代表性的环境污染物在普通人群中的暴露数据。这项工作将为政府制定环境污染防治政策提供科学依据。人体生物监测的目标之一是提供人体生物样本中化学污染物的准确和可比数据。从分析方法、实验空白、分析过程等方面对化学污染物进行有针对性的定量分析,实施多维度的质量控制措施。质量控制程序分为两个阶段:(1)在预检测阶段侧重于生物监测分析方法的验证、空白筛选和控制;(2)在检测阶段对大规模样品分析过程进行质量控制。CNHBP中使用的分析方法需要进行验证,以评价其性能和实用性,重点是方法检出限(MDL)和方法定量限(MQL)、基质效应、稳定性、残留和稀释度。所有监测指标均需进行空白筛选程序,以识别、消除或减少空白干扰,且每批空白值应小于MDL。本实验室采用内外部相结合的质量控制措施,措施主要包括:(1) 10类监测指标的方法验证和检测过程均采用美国国家标准技术研究院(NIST)、欧洲标准物质中心(ERM)和中国标准物质中心生产的生物基质标准物质;(2)采用商业质控样品和内部质控样品对15类监测指标检测过程的稳定性进行评价;(3)9类共60个监测指标参加了德国生物材料分析外部质量评估计划(G-EQUAS),并取得了满意的结果;(4)对15类监测指标进行了测试盲目的样本。总体而言,多维质量控制措施为生成高质量的生物监测数据提供了专业支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

[Quality control strategy for targeted quantitative analysis of chemical pollutants in China National Human Biomonitoring Program].

[Quality control strategy for targeted quantitative analysis of chemical pollutants in China National Human Biomonitoring Program].

The China National Human Biomonitoring Program (CNHBP) was launched in 2016. The program aims to obtain representative exposure data of environmental pollutants in the general population by carrying out field epidemiological surveys of Chinese population and monitoring of environmental pollutants in human biological tissues. This work will provide a scientific basis for the government to formulate environmental pollution prevention and control policies. One of the objectives of human biomonitoring is to provide accurate and comparable data of chemical pollutants in human biological samples. Multi-dimensional quality control measures are implemented for the targeted quantitative analysis of chemical pollutants from the analysis method, experimental blank and analysis processes. The quality control procedures are divided into two stages: (1) focusing on the verification of biomonitoring analysis method, blank screening and control in the pre-detection stage; (2) the quality control of the large-scale sample analysis process in the detection stage. Analysis methods used in CNHBP need to be validated to evaluate the performance and practicability, with emphasis on method detection limit (MDL) and method quantification limit (MQL), matrix effects, stability, and residue and dilution. Blank screening procedures are required for all monitoring indicators to identify, eliminate or reduce blank interference, and the blank value of each batch should be less than the MDL. The laboratory adopts a combination of internal and external quality control measures, the measures mainly include: (1) method validation and detection process of the 10 types of monitoring indicators all used biological matrix reference materials produced by the National Institute of Standards and Technology (NIST), European Reference Materials (ERM) and China Center for Reference Materials, to ensure the accuracy and traceability of the methods; (2) commercial quality control samples and internal quality control samples were used to evaluate the stability of the testing process for the 15 types of monitoring indicators; (3) a total of 60 monitoring indicators of the nine categories participated in the German external quality assessment scheme for analyses in biological materials (G-EQUAS) and achieved satisfactory results; (4) 15 types of monitoring indicators were tested with blind samples. Overall, multi-dimensional quality control measures provide professional support for generating high-quality biomonitoring data.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信