{"title":"在机器人辅助胸外科手术中使用组织隧道引导器自动缝合装置。","authors":"Tomohiko Matsuzaki, Hiroto Onozawa, Atsushi Wada, Naohiro Aruga, Masayuki Iwazaki, Ryota Masuda","doi":"10.1007/s11748-025-02141-2","DOIUrl":null,"url":null,"abstract":"<p><p>The SureForm stapler curved tip is a useful approach for vessels. Unless adequate space is maintained below the vessels, damage to the back of vessels with the curved tip may occur. The recommended methods include passing silk threads or vessel loops under the vessels and applying traction or using a Penrose drain to guide the tip of the stapler during insertion. However, these methods often risk putting tension on the vessels or becoming caught in the surrounding tissues. Additionally, the Penrose drain is soft, causing difficultly in guiding the stapler effectively. Furthermore, after removing the Penrose drain, there is a risk of accidental vascular injury by the tip of the stapler. To improve safety and efficiency, we devised a new method using a Tissuetunneler, which guides the stapler properly, prevents entanglement, and allows vessel transection without removal, reducing surgical time.</p>","PeriodicalId":12585,"journal":{"name":"General Thoracic and Cardiovascular Surgery","volume":" ","pages":"637-640"},"PeriodicalIF":1.1000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of a Tissuetunneler guide for an automatic suture device in robot-assisted thoracic surgery.\",\"authors\":\"Tomohiko Matsuzaki, Hiroto Onozawa, Atsushi Wada, Naohiro Aruga, Masayuki Iwazaki, Ryota Masuda\",\"doi\":\"10.1007/s11748-025-02141-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The SureForm stapler curved tip is a useful approach for vessels. Unless adequate space is maintained below the vessels, damage to the back of vessels with the curved tip may occur. The recommended methods include passing silk threads or vessel loops under the vessels and applying traction or using a Penrose drain to guide the tip of the stapler during insertion. However, these methods often risk putting tension on the vessels or becoming caught in the surrounding tissues. Additionally, the Penrose drain is soft, causing difficultly in guiding the stapler effectively. Furthermore, after removing the Penrose drain, there is a risk of accidental vascular injury by the tip of the stapler. To improve safety and efficiency, we devised a new method using a Tissuetunneler, which guides the stapler properly, prevents entanglement, and allows vessel transection without removal, reducing surgical time.</p>\",\"PeriodicalId\":12585,\"journal\":{\"name\":\"General Thoracic and Cardiovascular Surgery\",\"volume\":\" \",\"pages\":\"637-640\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"General Thoracic and Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11748-025-02141-2\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/5/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"General Thoracic and Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11748-025-02141-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/5/20 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Use of a Tissuetunneler guide for an automatic suture device in robot-assisted thoracic surgery.
The SureForm stapler curved tip is a useful approach for vessels. Unless adequate space is maintained below the vessels, damage to the back of vessels with the curved tip may occur. The recommended methods include passing silk threads or vessel loops under the vessels and applying traction or using a Penrose drain to guide the tip of the stapler during insertion. However, these methods often risk putting tension on the vessels or becoming caught in the surrounding tissues. Additionally, the Penrose drain is soft, causing difficultly in guiding the stapler effectively. Furthermore, after removing the Penrose drain, there is a risk of accidental vascular injury by the tip of the stapler. To improve safety and efficiency, we devised a new method using a Tissuetunneler, which guides the stapler properly, prevents entanglement, and allows vessel transection without removal, reducing surgical time.
期刊介绍:
The General Thoracic and Cardiovascular Surgery is the official publication of The Japanese Association for Thoracic Surgery and The Japanese Association for Chest Surgery, the affiliated journal of The Japanese Society for Cardiovascular Surgery, that publishes clinical and experimental studies in fields related to thoracic and cardiovascular surgery.