{"title":"基于约束的心电图和动脉压评估不能可靠地检测药物引起的QTc延长和低血压:来自病例研究的证据","authors":"Kim A. Henderson, Nicholas Ether, Hugo M. Vargas","doi":"10.1111/cts.70249","DOIUrl":null,"url":null,"abstract":"<p>Telemetry-based methods are recommended as best practice for monitoring changes in cardiovascular (CV) function in conscious nonrodent species during the development of new chemical entities. Such methods allow for unrestrained data collection in animals over extended time periods with high sensitivity to detect small effects. The CV profile of new drugs is also assessed in repeat-dose toxicology studies, routinely utilizing non-invasive blood pressure, heart rate, and ECG measurement methods that require physical or chemical restraint. These methods are limited to a short “snapshot” data collection period and incur physiological stress and behavioral excitement from handling/restraint during data collection. The resultant sympathetic activation impacts heart rate, blood pressure, and ECG intervals, causing increased variability and reduced sensitivity. Nonclinical best practices have been defined for standalone CV telemetry studies to support an integrated QTc risk assessment (ICH E14/S7B Q&A 5.1 & 6.1) using non-restraint telemetry methods; however, the pharmacological and statistical sensitivity of restraint-based methods used in repeat-dose toxicology studies is a gap. This paper retrospectively analyzed two case studies (AMG 319 and AMG 337) in which proprietary small molecules were evaluated by both non-restraint-based telemetry and restraint-based methods. AMG 319 and AMG 337 caused QTc interval prolongation and hypotension, respectively, in telemetry studies, which were also observed clinically with these compounds. However, in toxicology studies in which restraint-based ECG and blood pressure methods were used, CV effects were missed, blunted, or directionally wrong. These case studies highlight the need for the utilization of unrestrained telemetry methods over restraint-based methods.</p>","PeriodicalId":50610,"journal":{"name":"Cts-Clinical and Translational Science","volume":"18 5","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cts.70249","citationCount":"0","resultStr":"{\"title\":\"Restraint-Based ECG and Arterial Pressure Assessment Do Not Reliably Detect Drug Induced QTc Prolongation and Hypotension: Evidence From Case Studies\",\"authors\":\"Kim A. Henderson, Nicholas Ether, Hugo M. Vargas\",\"doi\":\"10.1111/cts.70249\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Telemetry-based methods are recommended as best practice for monitoring changes in cardiovascular (CV) function in conscious nonrodent species during the development of new chemical entities. Such methods allow for unrestrained data collection in animals over extended time periods with high sensitivity to detect small effects. The CV profile of new drugs is also assessed in repeat-dose toxicology studies, routinely utilizing non-invasive blood pressure, heart rate, and ECG measurement methods that require physical or chemical restraint. These methods are limited to a short “snapshot” data collection period and incur physiological stress and behavioral excitement from handling/restraint during data collection. The resultant sympathetic activation impacts heart rate, blood pressure, and ECG intervals, causing increased variability and reduced sensitivity. Nonclinical best practices have been defined for standalone CV telemetry studies to support an integrated QTc risk assessment (ICH E14/S7B Q&A 5.1 & 6.1) using non-restraint telemetry methods; however, the pharmacological and statistical sensitivity of restraint-based methods used in repeat-dose toxicology studies is a gap. This paper retrospectively analyzed two case studies (AMG 319 and AMG 337) in which proprietary small molecules were evaluated by both non-restraint-based telemetry and restraint-based methods. AMG 319 and AMG 337 caused QTc interval prolongation and hypotension, respectively, in telemetry studies, which were also observed clinically with these compounds. However, in toxicology studies in which restraint-based ECG and blood pressure methods were used, CV effects were missed, blunted, or directionally wrong. These case studies highlight the need for the utilization of unrestrained telemetry methods over restraint-based methods.</p>\",\"PeriodicalId\":50610,\"journal\":{\"name\":\"Cts-Clinical and Translational Science\",\"volume\":\"18 5\",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2025-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cts.70249\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cts-Clinical and Translational Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/cts.70249\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cts-Clinical and Translational Science","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cts.70249","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
Restraint-Based ECG and Arterial Pressure Assessment Do Not Reliably Detect Drug Induced QTc Prolongation and Hypotension: Evidence From Case Studies
Telemetry-based methods are recommended as best practice for monitoring changes in cardiovascular (CV) function in conscious nonrodent species during the development of new chemical entities. Such methods allow for unrestrained data collection in animals over extended time periods with high sensitivity to detect small effects. The CV profile of new drugs is also assessed in repeat-dose toxicology studies, routinely utilizing non-invasive blood pressure, heart rate, and ECG measurement methods that require physical or chemical restraint. These methods are limited to a short “snapshot” data collection period and incur physiological stress and behavioral excitement from handling/restraint during data collection. The resultant sympathetic activation impacts heart rate, blood pressure, and ECG intervals, causing increased variability and reduced sensitivity. Nonclinical best practices have been defined for standalone CV telemetry studies to support an integrated QTc risk assessment (ICH E14/S7B Q&A 5.1 & 6.1) using non-restraint telemetry methods; however, the pharmacological and statistical sensitivity of restraint-based methods used in repeat-dose toxicology studies is a gap. This paper retrospectively analyzed two case studies (AMG 319 and AMG 337) in which proprietary small molecules were evaluated by both non-restraint-based telemetry and restraint-based methods. AMG 319 and AMG 337 caused QTc interval prolongation and hypotension, respectively, in telemetry studies, which were also observed clinically with these compounds. However, in toxicology studies in which restraint-based ECG and blood pressure methods were used, CV effects were missed, blunted, or directionally wrong. These case studies highlight the need for the utilization of unrestrained telemetry methods over restraint-based methods.
期刊介绍:
Clinical and Translational Science (CTS), an official journal of the American Society for Clinical Pharmacology and Therapeutics, highlights original translational medicine research that helps bridge laboratory discoveries with the diagnosis and treatment of human disease. Translational medicine is a multi-faceted discipline with a focus on translational therapeutics. In a broad sense, translational medicine bridges across the discovery, development, regulation, and utilization spectrum. Research may appear as Full Articles, Brief Reports, Commentaries, Phase Forwards (clinical trials), Reviews, or Tutorials. CTS also includes invited didactic content that covers the connections between clinical pharmacology and translational medicine. Best-in-class methodologies and best practices are also welcomed as Tutorials. These additional features provide context for research articles and facilitate understanding for a wide array of individuals interested in clinical and translational science. CTS welcomes high quality, scientifically sound, original manuscripts focused on clinical pharmacology and translational science, including animal, in vitro, in silico, and clinical studies supporting the breadth of drug discovery, development, regulation and clinical use of both traditional drugs and innovative modalities.