Jakob Vorlaufer, Nikolai Semenov, Caroline Kreuzinger, Manjunath G Javoor, Bettina Zens, Nathalie Agudelo Dueñas, Mojtaba R Tavakoli, Marek Šuplata, Wiebke Jahr, Julia Lyudchik, Andreas Wartak, Florian K M Schur, Johann G Danzl
{"title":"基于图像的纳米尺度光学显微镜三维主动稳像技术。","authors":"Jakob Vorlaufer, Nikolai Semenov, Caroline Kreuzinger, Manjunath G Javoor, Bettina Zens, Nathalie Agudelo Dueñas, Mojtaba R Tavakoli, Marek Šuplata, Wiebke Jahr, Julia Lyudchik, Andreas Wartak, Florian K M Schur, Johann G Danzl","doi":"10.1016/j.bpr.2025.100211","DOIUrl":null,"url":null,"abstract":"<p><p>Super-resolution microscopy often entails long acquisition times of minutes to hours. Since drifts during the acquisition adversely affect data quality, active sample stabilization is commonly used for some of these techniques to reach their full potential. Although drifts in the lateral plane can often be corrected after acquisition, this is not always possible or may come with drawbacks. Therefore, it is appealing to stabilize sample position in three dimensions (3D) during acquisition. Various schemes for active sample stabilization have been demonstrated previously, with some reaching sub-nanometer stability in 3D. Here, we present a scheme for active drift correction that delivers the nanometer-scale 3D stability demanded by state-of-the-art super-resolution techniques and is straightforward to implement compared to previous schemes capable of reaching this level of stabilization precision. Using a refined algorithm that can handle various types of reference structure, without sparse signal peaks being mandatory, we stabilized sample position to ∼1 nm in 3D using objective lenses both with high and low numerical aperture. Our implementation requires only the addition of a simple widefield imaging path and we provide an open-source control software with graphical user interface to facilitate easy adoption of the module. Finally, we demonstrate how this has the potential to enhance data collection for diffraction-limited and super-resolution imaging techniques using single-molecule localization microscopy and cryo-confocal imaging as showcases.</p>","PeriodicalId":72402,"journal":{"name":"Biophysical reports","volume":" ","pages":"100211"},"PeriodicalIF":2.7000,"publicationDate":"2025-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12166792/pdf/","citationCount":"0","resultStr":"{\"title\":\"Image-based 3D active sample stabilization on the nanometer scale for optical microscopy.\",\"authors\":\"Jakob Vorlaufer, Nikolai Semenov, Caroline Kreuzinger, Manjunath G Javoor, Bettina Zens, Nathalie Agudelo Dueñas, Mojtaba R Tavakoli, Marek Šuplata, Wiebke Jahr, Julia Lyudchik, Andreas Wartak, Florian K M Schur, Johann G Danzl\",\"doi\":\"10.1016/j.bpr.2025.100211\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Super-resolution microscopy often entails long acquisition times of minutes to hours. Since drifts during the acquisition adversely affect data quality, active sample stabilization is commonly used for some of these techniques to reach their full potential. Although drifts in the lateral plane can often be corrected after acquisition, this is not always possible or may come with drawbacks. Therefore, it is appealing to stabilize sample position in three dimensions (3D) during acquisition. Various schemes for active sample stabilization have been demonstrated previously, with some reaching sub-nanometer stability in 3D. Here, we present a scheme for active drift correction that delivers the nanometer-scale 3D stability demanded by state-of-the-art super-resolution techniques and is straightforward to implement compared to previous schemes capable of reaching this level of stabilization precision. Using a refined algorithm that can handle various types of reference structure, without sparse signal peaks being mandatory, we stabilized sample position to ∼1 nm in 3D using objective lenses both with high and low numerical aperture. Our implementation requires only the addition of a simple widefield imaging path and we provide an open-source control software with graphical user interface to facilitate easy adoption of the module. Finally, we demonstrate how this has the potential to enhance data collection for diffraction-limited and super-resolution imaging techniques using single-molecule localization microscopy and cryo-confocal imaging as showcases.</p>\",\"PeriodicalId\":72402,\"journal\":{\"name\":\"Biophysical reports\",\"volume\":\" \",\"pages\":\"100211\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2025-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12166792/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biophysical reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.bpr.2025.100211\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/5/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biophysical reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.bpr.2025.100211","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/5/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
Image-based 3D active sample stabilization on the nanometer scale for optical microscopy.
Super-resolution microscopy often entails long acquisition times of minutes to hours. Since drifts during the acquisition adversely affect data quality, active sample stabilization is commonly used for some of these techniques to reach their full potential. Although drifts in the lateral plane can often be corrected after acquisition, this is not always possible or may come with drawbacks. Therefore, it is appealing to stabilize sample position in three dimensions (3D) during acquisition. Various schemes for active sample stabilization have been demonstrated previously, with some reaching sub-nanometer stability in 3D. Here, we present a scheme for active drift correction that delivers the nanometer-scale 3D stability demanded by state-of-the-art super-resolution techniques and is straightforward to implement compared to previous schemes capable of reaching this level of stabilization precision. Using a refined algorithm that can handle various types of reference structure, without sparse signal peaks being mandatory, we stabilized sample position to ∼1 nm in 3D using objective lenses both with high and low numerical aperture. Our implementation requires only the addition of a simple widefield imaging path and we provide an open-source control software with graphical user interface to facilitate easy adoption of the module. Finally, we demonstrate how this has the potential to enhance data collection for diffraction-limited and super-resolution imaging techniques using single-molecule localization microscopy and cryo-confocal imaging as showcases.