Ruiyan Ni, Elizabeth Chuk, Kathy Han, Jennifer Croke, Anthony Fyles, Jelena Lukovic, Michael Milosevic, Benjamin Haibe-Kains, Alexandra Rink
{"title":"基于深度学习的高危器官分割的几何聚焦训练与评估。","authors":"Ruiyan Ni, Elizabeth Chuk, Kathy Han, Jennifer Croke, Anthony Fyles, Jelena Lukovic, Michael Milosevic, Benjamin Haibe-Kains, Alexandra Rink","doi":"10.1002/mp.17840","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Deep learning methods are promising in automating segmentation of organs at risk (OARs) in radiotherapy. However, the lack of a geometric indicator for dosimetry accuracy remains to be a problem. This issue is particularly pronounced in specific radiotherapy treatments where only the proximity of structures to the radiotherapy target affects the dose planning. In cervical cancer high dose-rate (HDR) brachytherapy, treatment planning is motivated by limiting dose to the hottest 2 cubic centimeters (D2cm<sup>3</sup>) of the OARs. Similarly, Ethos online adaptive radiotherapy system prioritizes only the closest target structures for adaptive plan generation.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>We propose a novel geometrically focused deep learning training method and evaluation metric, using cervical brachytherapy as a case study. A distance-penalized (DP) loss function was developed to focus attention on the near-to-target OAR regions. We also introduced and evaluated a novel geometric metric, weighted dice similarity coefficient (wDSC), correlated with OARs D2cm<sup>3</sup>.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A model was trained using a 3D U-Net architecture and 170 T2-weighted magnetic resonance (MR) images (56 patients) with clinical contours. The dataset was split into subsets at the patient level: 45 patients (150 scans) as the training set for five-fold cross-validation and 11 patients (20 scans) as the testing set. Another dataset from our institution, consisting of 35 MR scans from 22 cervical cancer patients, was used as an independent internal testing set. A distance map, emphasizing errors near high-risk clinical target volume (CTV<sub>HR</sub>), was used to penalize two commonly used loss functions, cross-entropy (CE) loss and DiceCE loss. The wDSC emphasizes the accuracy of OAR regions proximal to CTV<sub>HR</sub> by incorporating a weighted factor in the original vDSC. The Pearson correlation coefficient (<i>r</i>) was used to quantify the strength of the relationship between D2cm<sup>3</sup> accuracy and six evaluation metrics (wDSC and five standard metrics). A physician rated and revised the auto-contours for the clinical acceptability tests.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The wDSC moderately correlated (<i>r</i> = -0.55) with D2cm<sup>3</sup> accuracy, outperforming standard geometric metrics. Models using DP loss functions consistently yielded higher wDSCs compared to their respective non-DP counterparts. DP loss models also improved D2cm<sup>3</sup> accuracy, indicating an enhanced accuracy in dosimetry. The clinical acceptability tests revealed that more than 94% of bladder and rectum contours and approximately half of the sigmoid and small bowel contours were clinically accepted.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>We developed and evaluated a new geometric metric, wDSC, as a better indicator of D2cm<sup>3</sup> accuracy, which has the potential to become a surrogate for dosimetric accuracy in cervical brachytherapy. The model with DP loss showed non-statistically significant improvements in geometric and dosimetric performance. This work also holds the potential to be used for precise OARs delineation in adaptive radiotherapy.</p>\n </section>\n </div>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"52 7","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/mp.17840","citationCount":"0","resultStr":"{\"title\":\"Geometrically focused training and evaluation of organs-at-risk segmentation via deep learning\",\"authors\":\"Ruiyan Ni, Elizabeth Chuk, Kathy Han, Jennifer Croke, Anthony Fyles, Jelena Lukovic, Michael Milosevic, Benjamin Haibe-Kains, Alexandra Rink\",\"doi\":\"10.1002/mp.17840\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Deep learning methods are promising in automating segmentation of organs at risk (OARs) in radiotherapy. However, the lack of a geometric indicator for dosimetry accuracy remains to be a problem. This issue is particularly pronounced in specific radiotherapy treatments where only the proximity of structures to the radiotherapy target affects the dose planning. In cervical cancer high dose-rate (HDR) brachytherapy, treatment planning is motivated by limiting dose to the hottest 2 cubic centimeters (D2cm<sup>3</sup>) of the OARs. Similarly, Ethos online adaptive radiotherapy system prioritizes only the closest target structures for adaptive plan generation.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>We propose a novel geometrically focused deep learning training method and evaluation metric, using cervical brachytherapy as a case study. A distance-penalized (DP) loss function was developed to focus attention on the near-to-target OAR regions. We also introduced and evaluated a novel geometric metric, weighted dice similarity coefficient (wDSC), correlated with OARs D2cm<sup>3</sup>.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>A model was trained using a 3D U-Net architecture and 170 T2-weighted magnetic resonance (MR) images (56 patients) with clinical contours. The dataset was split into subsets at the patient level: 45 patients (150 scans) as the training set for five-fold cross-validation and 11 patients (20 scans) as the testing set. Another dataset from our institution, consisting of 35 MR scans from 22 cervical cancer patients, was used as an independent internal testing set. A distance map, emphasizing errors near high-risk clinical target volume (CTV<sub>HR</sub>), was used to penalize two commonly used loss functions, cross-entropy (CE) loss and DiceCE loss. The wDSC emphasizes the accuracy of OAR regions proximal to CTV<sub>HR</sub> by incorporating a weighted factor in the original vDSC. The Pearson correlation coefficient (<i>r</i>) was used to quantify the strength of the relationship between D2cm<sup>3</sup> accuracy and six evaluation metrics (wDSC and five standard metrics). A physician rated and revised the auto-contours for the clinical acceptability tests.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>The wDSC moderately correlated (<i>r</i> = -0.55) with D2cm<sup>3</sup> accuracy, outperforming standard geometric metrics. Models using DP loss functions consistently yielded higher wDSCs compared to their respective non-DP counterparts. DP loss models also improved D2cm<sup>3</sup> accuracy, indicating an enhanced accuracy in dosimetry. The clinical acceptability tests revealed that more than 94% of bladder and rectum contours and approximately half of the sigmoid and small bowel contours were clinically accepted.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>We developed and evaluated a new geometric metric, wDSC, as a better indicator of D2cm<sup>3</sup> accuracy, which has the potential to become a surrogate for dosimetric accuracy in cervical brachytherapy. The model with DP loss showed non-statistically significant improvements in geometric and dosimetric performance. This work also holds the potential to be used for precise OARs delineation in adaptive radiotherapy.</p>\\n </section>\\n </div>\",\"PeriodicalId\":18384,\"journal\":{\"name\":\"Medical physics\",\"volume\":\"52 7\",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-04-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/mp.17840\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/mp.17840\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mp.17840","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Geometrically focused training and evaluation of organs-at-risk segmentation via deep learning
Background
Deep learning methods are promising in automating segmentation of organs at risk (OARs) in radiotherapy. However, the lack of a geometric indicator for dosimetry accuracy remains to be a problem. This issue is particularly pronounced in specific radiotherapy treatments where only the proximity of structures to the radiotherapy target affects the dose planning. In cervical cancer high dose-rate (HDR) brachytherapy, treatment planning is motivated by limiting dose to the hottest 2 cubic centimeters (D2cm3) of the OARs. Similarly, Ethos online adaptive radiotherapy system prioritizes only the closest target structures for adaptive plan generation.
Purpose
We propose a novel geometrically focused deep learning training method and evaluation metric, using cervical brachytherapy as a case study. A distance-penalized (DP) loss function was developed to focus attention on the near-to-target OAR regions. We also introduced and evaluated a novel geometric metric, weighted dice similarity coefficient (wDSC), correlated with OARs D2cm3.
Methods
A model was trained using a 3D U-Net architecture and 170 T2-weighted magnetic resonance (MR) images (56 patients) with clinical contours. The dataset was split into subsets at the patient level: 45 patients (150 scans) as the training set for five-fold cross-validation and 11 patients (20 scans) as the testing set. Another dataset from our institution, consisting of 35 MR scans from 22 cervical cancer patients, was used as an independent internal testing set. A distance map, emphasizing errors near high-risk clinical target volume (CTVHR), was used to penalize two commonly used loss functions, cross-entropy (CE) loss and DiceCE loss. The wDSC emphasizes the accuracy of OAR regions proximal to CTVHR by incorporating a weighted factor in the original vDSC. The Pearson correlation coefficient (r) was used to quantify the strength of the relationship between D2cm3 accuracy and six evaluation metrics (wDSC and five standard metrics). A physician rated and revised the auto-contours for the clinical acceptability tests.
Results
The wDSC moderately correlated (r = -0.55) with D2cm3 accuracy, outperforming standard geometric metrics. Models using DP loss functions consistently yielded higher wDSCs compared to their respective non-DP counterparts. DP loss models also improved D2cm3 accuracy, indicating an enhanced accuracy in dosimetry. The clinical acceptability tests revealed that more than 94% of bladder and rectum contours and approximately half of the sigmoid and small bowel contours were clinically accepted.
Conclusion
We developed and evaluated a new geometric metric, wDSC, as a better indicator of D2cm3 accuracy, which has the potential to become a surrogate for dosimetric accuracy in cervical brachytherapy. The model with DP loss showed non-statistically significant improvements in geometric and dosimetric performance. This work also holds the potential to be used for precise OARs delineation in adaptive radiotherapy.
期刊介绍:
Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments
Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.