多病人模式下CT造影剂注射器optivadvantage的安全性和性能。

IF 1.3 Q4 ENGINEERING, BIOMEDICAL
Medical Devices-Evidence and Research Pub Date : 2025-04-12 eCollection Date: 2025-01-01 DOI:10.2147/MDER.S507263
Angela Tirri, Filippo Nicolò Iannelli, Anthony Sequeira, Frantz Hebert
{"title":"多病人模式下CT造影剂注射器optivadvantage的安全性和性能。","authors":"Angela Tirri, Filippo Nicolò Iannelli, Anthony Sequeira, Frantz Hebert","doi":"10.2147/MDER.S507263","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the safety, performance and user's satisfaction of OptiVantage<sup>®</sup>, a dual head CT Contrast Delivery System, in multi-patient mode for patients requiring a contrast-enhanced CT examination.</p><p><strong>Patients and methods: </strong>A total of 100 subjects were included in this multicentre observational clinical investigation, conducted between April 20, 2023, and October 6, 2023. The primary endpoint for safety was the rate of extravasation, and the primary endpoint for performance was the success of injection assessed by the investigator. Secondary endpoints for safety were the rates of air embolism and sepsis as well as adverse events (AE) related to the injection. Other data collected included indication, set-up time, injection parameters and user's satisfaction.</p><p><strong>Results: </strong>The study population included 59% of women. The mean age was 63.6 ± 12.7 years (range: 18 to 83 years), with the majority of patients (55%) older than 65 years. The main indications for undergoing contrast-enhanced CT were breast cancer, colon cancer and lung cancer or nodules. The mean volume injected was 119.5 ± 14.4 mL and the injection rate ranged from 2.8 to 4.5 mL/s (mean; 3.6 ± 0.3 mL/s). No extravasation or other adverse event, including air embolism and sepsis, was reported in any of the subjects (95% CI: [0.00%, 3.62%]). All the injections (100%; 95% CI: 95.39%, 100.00%) were considered as successful for the obtention of diagnostic images. The preparation of the subject, including the setting of the patient line, took between 6 and 10 seconds in most cases (68%) and 16 to 20 seconds for 30 patients (30%). The dayset was changed for 15 subjects and in all cases, it took no more than one minute.</p><p><strong>Conclusion: </strong>In conclusion, this study confirms the safety and performance of the OptiVantage<sup>®</sup> Dual head in multi-use mode for contrast injection in adult patients, particularly elderly, undergoing contrast-enhanced CT.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":"18 ","pages":"233-240"},"PeriodicalIF":1.3000,"publicationDate":"2025-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12002069/pdf/","citationCount":"0","resultStr":"{\"title\":\"Safety and Performance of OptiVantage, a CT Contrast Media Injector, in Multi-Patient Mode.\",\"authors\":\"Angela Tirri, Filippo Nicolò Iannelli, Anthony Sequeira, Frantz Hebert\",\"doi\":\"10.2147/MDER.S507263\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the safety, performance and user's satisfaction of OptiVantage<sup>®</sup>, a dual head CT Contrast Delivery System, in multi-patient mode for patients requiring a contrast-enhanced CT examination.</p><p><strong>Patients and methods: </strong>A total of 100 subjects were included in this multicentre observational clinical investigation, conducted between April 20, 2023, and October 6, 2023. The primary endpoint for safety was the rate of extravasation, and the primary endpoint for performance was the success of injection assessed by the investigator. Secondary endpoints for safety were the rates of air embolism and sepsis as well as adverse events (AE) related to the injection. Other data collected included indication, set-up time, injection parameters and user's satisfaction.</p><p><strong>Results: </strong>The study population included 59% of women. The mean age was 63.6 ± 12.7 years (range: 18 to 83 years), with the majority of patients (55%) older than 65 years. The main indications for undergoing contrast-enhanced CT were breast cancer, colon cancer and lung cancer or nodules. The mean volume injected was 119.5 ± 14.4 mL and the injection rate ranged from 2.8 to 4.5 mL/s (mean; 3.6 ± 0.3 mL/s). No extravasation or other adverse event, including air embolism and sepsis, was reported in any of the subjects (95% CI: [0.00%, 3.62%]). All the injections (100%; 95% CI: 95.39%, 100.00%) were considered as successful for the obtention of diagnostic images. The preparation of the subject, including the setting of the patient line, took between 6 and 10 seconds in most cases (68%) and 16 to 20 seconds for 30 patients (30%). The dayset was changed for 15 subjects and in all cases, it took no more than one minute.</p><p><strong>Conclusion: </strong>In conclusion, this study confirms the safety and performance of the OptiVantage<sup>®</sup> Dual head in multi-use mode for contrast injection in adult patients, particularly elderly, undergoing contrast-enhanced CT.</p>\",\"PeriodicalId\":47140,\"journal\":{\"name\":\"Medical Devices-Evidence and Research\",\"volume\":\"18 \",\"pages\":\"233-240\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12002069/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Devices-Evidence and Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/MDER.S507263\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S507263","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估optivvantage®双头CT造影剂输送系统在多患者模式下的安全性、性能和用户满意度,用于需要增强CT检查的患者。患者和方法:这项多中心观察性临床研究共纳入100名受试者,于2023年4月20日至2023年10月6日进行。安全性的主要终点是外渗率,性能的主要终点是研究者评估的注射成功。安全性的次要终点是空气栓塞和败血症的发生率以及与注射相关的不良事件(AE)。收集的其他数据包括指示、设置时间、注射参数和用户满意度。结果:研究人群包括59%的女性。平均年龄为63.6±12.7岁(范围:18 ~ 83岁),大多数患者(55%)年龄大于65岁。增强CT的主要适应症为乳腺癌、结肠癌、肺癌或结节。平均注射体积为119.5±14.4 mL,注射速度为2.8 ~ 4.5 mL/s(平均;3.6±0.3 mL/s)。所有受试者均未报告外渗或其他不良事件,包括空气栓塞和败血症(95% CI:[0.00%, 3.62%])。所有注射(100%;95% CI: 95.39%, 100.00%)被认为是成功的诊断图像的注意。受试者的准备,包括患者线的设置,在大多数情况下需要6到10秒(68%),30名患者(30%)需要16到20秒。改变了15名受试者的作息时间,在所有情况下,时间都不超过一分钟。结论:综上所述,本研究证实了OptiVantage®双头部在多用途模式下用于成年患者,特别是老年人进行对比增强CT注射造影剂的安全性和性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Safety and Performance of OptiVantage, a CT Contrast Media Injector, in Multi-Patient Mode.

Purpose: To evaluate the safety, performance and user's satisfaction of OptiVantage®, a dual head CT Contrast Delivery System, in multi-patient mode for patients requiring a contrast-enhanced CT examination.

Patients and methods: A total of 100 subjects were included in this multicentre observational clinical investigation, conducted between April 20, 2023, and October 6, 2023. The primary endpoint for safety was the rate of extravasation, and the primary endpoint for performance was the success of injection assessed by the investigator. Secondary endpoints for safety were the rates of air embolism and sepsis as well as adverse events (AE) related to the injection. Other data collected included indication, set-up time, injection parameters and user's satisfaction.

Results: The study population included 59% of women. The mean age was 63.6 ± 12.7 years (range: 18 to 83 years), with the majority of patients (55%) older than 65 years. The main indications for undergoing contrast-enhanced CT were breast cancer, colon cancer and lung cancer or nodules. The mean volume injected was 119.5 ± 14.4 mL and the injection rate ranged from 2.8 to 4.5 mL/s (mean; 3.6 ± 0.3 mL/s). No extravasation or other adverse event, including air embolism and sepsis, was reported in any of the subjects (95% CI: [0.00%, 3.62%]). All the injections (100%; 95% CI: 95.39%, 100.00%) were considered as successful for the obtention of diagnostic images. The preparation of the subject, including the setting of the patient line, took between 6 and 10 seconds in most cases (68%) and 16 to 20 seconds for 30 patients (30%). The dayset was changed for 15 subjects and in all cases, it took no more than one minute.

Conclusion: In conclusion, this study confirms the safety and performance of the OptiVantage® Dual head in multi-use mode for contrast injection in adult patients, particularly elderly, undergoing contrast-enhanced CT.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信