Roberto Alvarez Coello, Muhieddine Omar Chokr, Rodrigo Melo Kulchetscki, Hugo Cardoso de Souza Falcon, Victor Hugo Dos Santos Sousa, Mauricio I Scanavacca
{"title":"主动脉瓣置换术后的心律失常晕厥。","authors":"Roberto Alvarez Coello, Muhieddine Omar Chokr, Rodrigo Melo Kulchetscki, Hugo Cardoso de Souza Falcon, Victor Hugo Dos Santos Sousa, Mauricio I Scanavacca","doi":"10.1111/pace.15192","DOIUrl":null,"url":null,"abstract":"<p><p>We present the case of a young man who suffered from severe aortic valve insufficiency and subsequently underwent mechanical aortic prosthesis replacement. One month post-surgery, he presented with syncope and incessant ventricular tachycardia (VT), progressing to cardiogenic shock, which required emergency intra-aortic balloon pump (IABP) support. The VT proved refractory to standard clinical management and demonstrated responsiveness only after IABP support. An electrophysiological study was conducted; however, VT could not be induced during the procedure. Through electrophysiological maneuvers, we suspected bundle branch reentrant ventricular tachycardia (BBR-VT), and successful treatment was achieved via right bundle branch (RBB) ablation.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":" ","pages":"598-602"},"PeriodicalIF":1.7000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Arrhythmic Syncope After Aortic Valve Replacement.\",\"authors\":\"Roberto Alvarez Coello, Muhieddine Omar Chokr, Rodrigo Melo Kulchetscki, Hugo Cardoso de Souza Falcon, Victor Hugo Dos Santos Sousa, Mauricio I Scanavacca\",\"doi\":\"10.1111/pace.15192\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We present the case of a young man who suffered from severe aortic valve insufficiency and subsequently underwent mechanical aortic prosthesis replacement. One month post-surgery, he presented with syncope and incessant ventricular tachycardia (VT), progressing to cardiogenic shock, which required emergency intra-aortic balloon pump (IABP) support. The VT proved refractory to standard clinical management and demonstrated responsiveness only after IABP support. An electrophysiological study was conducted; however, VT could not be induced during the procedure. Through electrophysiological maneuvers, we suspected bundle branch reentrant ventricular tachycardia (BBR-VT), and successful treatment was achieved via right bundle branch (RBB) ablation.</p>\",\"PeriodicalId\":54653,\"journal\":{\"name\":\"Pace-Pacing and Clinical Electrophysiology\",\"volume\":\" \",\"pages\":\"598-602\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pace-Pacing and Clinical Electrophysiology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/pace.15192\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/4/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.15192","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Arrhythmic Syncope After Aortic Valve Replacement.
We present the case of a young man who suffered from severe aortic valve insufficiency and subsequently underwent mechanical aortic prosthesis replacement. One month post-surgery, he presented with syncope and incessant ventricular tachycardia (VT), progressing to cardiogenic shock, which required emergency intra-aortic balloon pump (IABP) support. The VT proved refractory to standard clinical management and demonstrated responsiveness only after IABP support. An electrophysiological study was conducted; however, VT could not be induced during the procedure. Through electrophysiological maneuvers, we suspected bundle branch reentrant ventricular tachycardia (BBR-VT), and successful treatment was achieved via right bundle branch (RBB) ablation.
期刊介绍:
Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.