快速瑞沙-亚胺培南NP试验与常规圆盘扩散法检测鲍曼不动杆菌碳青霉烯类药敏的比较。

IF 0.7 4区 医学 Q3 MEDICINE, GENERAL & INTERNAL
Sidra Muqarrab, Irfan Ali Mirza, Sakeenah Hussain Naqvi, Asad Zafar, Adeel Hussain Gardezi, Rabia Sajjad
{"title":"快速瑞沙-亚胺培南NP试验与常规圆盘扩散法检测鲍曼不动杆菌碳青霉烯类药敏的比较。","authors":"Sidra Muqarrab, Irfan Ali Mirza, Sakeenah Hussain Naqvi, Asad Zafar, Adeel Hussain Gardezi, Rabia Sajjad","doi":"10.29271/jcpsp.2025.05.585","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare rapid Resa-Imipenem NP test with conventional disc-diffusion method for carbapenem susceptibility testing in Acinetobacter baumannii.</p><p><strong>Study design: </strong>Cross-sectional analytical study. Place and Duration of the Study: Department of Microbiology, The Armed Forces Institute of Pathology / National University of Medical Sciences, Rawalpindi, Pakistan, from December 2022 to November 2023.</p><p><strong>Methodology: </strong>A rapid resazurin-based test to assess imipenem susceptibility was performed on the growth of Acinetobacter baumannii in 202 clinical samples from different clinical settings, and the results were compared with the conventional disc-diffusion testing method. Bacterial suspensions of the isolates were added to imipenem and resazurin (a viability colourant) containing Mueller-Hinton broth on a 96-well polystyrene microtitre plate and incubated for 2.5 hours. A colour change from blue to pink indicated resistance. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. Cohen's kappa assessed agreement between tests.</p><p><strong>Results: </strong>Out of 202 isolates, 157 were imipenem resistant and 45 were imipenem sensitive. The sensitivity, specificity, PPV, and NPV were 99.4%, 100%, 100%, and 97.8%, respectively. Diagnostic accuracy was 99.5% with one very major error (VME, 0.5%). Cohen's Kappa showed excellent agreement between the two tests (<0.001).</p><p><strong>Conclusion: </strong>The rapid Resa-Imipenem NP test is simple, reliable, and significantly faster, providing accurate results within 2.5 hours compared to 18-24 hours by conventional disc-diffusion.</p><p><strong>Key words: </strong>Acinetobacter baumannii, Imipenem, Rapid resazurin test, Microbial sensitivity tests, Disk diffusion method, Carba-penems.</p>","PeriodicalId":54905,"journal":{"name":"Jcpsp-Journal of the College of Physicians and Surgeons Pakistan","volume":"35 5","pages":"585-589"},"PeriodicalIF":0.7000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Rapid Resa-Imipenem NP Test with Conventional Disc Diffusion Method for Detection of Carbapenem Susceptibility in <em>Acinetobacter Baumannii</em>.\",\"authors\":\"Sidra Muqarrab, Irfan Ali Mirza, Sakeenah Hussain Naqvi, Asad Zafar, Adeel Hussain Gardezi, Rabia Sajjad\",\"doi\":\"10.29271/jcpsp.2025.05.585\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To compare rapid Resa-Imipenem NP test with conventional disc-diffusion method for carbapenem susceptibility testing in Acinetobacter baumannii.</p><p><strong>Study design: </strong>Cross-sectional analytical study. Place and Duration of the Study: Department of Microbiology, The Armed Forces Institute of Pathology / National University of Medical Sciences, Rawalpindi, Pakistan, from December 2022 to November 2023.</p><p><strong>Methodology: </strong>A rapid resazurin-based test to assess imipenem susceptibility was performed on the growth of Acinetobacter baumannii in 202 clinical samples from different clinical settings, and the results were compared with the conventional disc-diffusion testing method. Bacterial suspensions of the isolates were added to imipenem and resazurin (a viability colourant) containing Mueller-Hinton broth on a 96-well polystyrene microtitre plate and incubated for 2.5 hours. A colour change from blue to pink indicated resistance. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. Cohen's kappa assessed agreement between tests.</p><p><strong>Results: </strong>Out of 202 isolates, 157 were imipenem resistant and 45 were imipenem sensitive. The sensitivity, specificity, PPV, and NPV were 99.4%, 100%, 100%, and 97.8%, respectively. Diagnostic accuracy was 99.5% with one very major error (VME, 0.5%). Cohen's Kappa showed excellent agreement between the two tests (<0.001).</p><p><strong>Conclusion: </strong>The rapid Resa-Imipenem NP test is simple, reliable, and significantly faster, providing accurate results within 2.5 hours compared to 18-24 hours by conventional disc-diffusion.</p><p><strong>Key words: </strong>Acinetobacter baumannii, Imipenem, Rapid resazurin test, Microbial sensitivity tests, Disk diffusion method, Carba-penems.</p>\",\"PeriodicalId\":54905,\"journal\":{\"name\":\"Jcpsp-Journal of the College of Physicians and Surgeons Pakistan\",\"volume\":\"35 5\",\"pages\":\"585-589\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jcpsp-Journal of the College of Physicians and Surgeons Pakistan\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.29271/jcpsp.2025.05.585\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jcpsp-Journal of the College of Physicians and Surgeons Pakistan","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.29271/jcpsp.2025.05.585","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较快速瑞沙-亚胺培南NP试验与常规纸片扩散法对鲍曼不动杆菌碳青霉烯类药敏试验的影响。研究设计:横断面分析研究。研究地点和时间:2022年12月至2023年11月,巴基斯坦拉瓦尔品第,武装部队病理研究所/国立医科大学微生物学系。方法:对202份不同临床环境的鲍曼不动杆菌进行亚胺培南敏感性快速检测,并与常规纸片扩散法进行比较。分离菌的菌悬液在96孔聚苯乙烯微滴板上加入含有穆勒-辛顿肉汤的亚胺培南和瑞祖林(一种活力着色剂),孵育2.5小时。颜色从蓝色变为粉红色表示抵抗。计算敏感性、特异性、阳性预测值(PPV)、阴性预测值(NPV)和诊断准确性。科恩的kappa评估了测试之间的一致性。结果:202株亚胺培南耐药157株,亚胺培南敏感45株。敏感性为99.4%,特异性为100%,PPV为100%,NPV为97.8%。诊断准确率为99.5%,有一个非常严重的错误(VME, 0.5%)。Cohen’s Kappa在两种检测方法之间表现出了极好的一致性(结论:快速瑞沙-亚胺培南NP检测简单、可靠,而且明显更快,与传统的圆盘扩散法18-24小时相比,2.5小时内就能提供准确的结果。关键词:鲍曼不动杆菌,亚胺培南,瑞唑脲快速试验,微生物敏感性试验,纸片扩散法,碳培南
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Rapid Resa-Imipenem NP Test with Conventional Disc Diffusion Method for Detection of Carbapenem Susceptibility in Acinetobacter Baumannii.

Objective: To compare rapid Resa-Imipenem NP test with conventional disc-diffusion method for carbapenem susceptibility testing in Acinetobacter baumannii.

Study design: Cross-sectional analytical study. Place and Duration of the Study: Department of Microbiology, The Armed Forces Institute of Pathology / National University of Medical Sciences, Rawalpindi, Pakistan, from December 2022 to November 2023.

Methodology: A rapid resazurin-based test to assess imipenem susceptibility was performed on the growth of Acinetobacter baumannii in 202 clinical samples from different clinical settings, and the results were compared with the conventional disc-diffusion testing method. Bacterial suspensions of the isolates were added to imipenem and resazurin (a viability colourant) containing Mueller-Hinton broth on a 96-well polystyrene microtitre plate and incubated for 2.5 hours. A colour change from blue to pink indicated resistance. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. Cohen's kappa assessed agreement between tests.

Results: Out of 202 isolates, 157 were imipenem resistant and 45 were imipenem sensitive. The sensitivity, specificity, PPV, and NPV were 99.4%, 100%, 100%, and 97.8%, respectively. Diagnostic accuracy was 99.5% with one very major error (VME, 0.5%). Cohen's Kappa showed excellent agreement between the two tests (<0.001).

Conclusion: The rapid Resa-Imipenem NP test is simple, reliable, and significantly faster, providing accurate results within 2.5 hours compared to 18-24 hours by conventional disc-diffusion.

Key words: Acinetobacter baumannii, Imipenem, Rapid resazurin test, Microbial sensitivity tests, Disk diffusion method, Carba-penems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
453
审稿时长
3-6 weeks
期刊介绍: Journal of College of Physicians and Surgeons Pakistan (JCPSP), is the prestigious, peer reviewed monthly biomedical journal of the country published regularly since 1991. Established with the primary aim of promotion and dissemination of medical research and contributed by scholars of biomedical sciences from Pakistan and abroad, it carries original research papers, , case reports, review articles, articles on medical education, commentaries, short communication, new technology, editorials and letters to the editor. It covers the core biomedical health science subjects, basic medical sciences and emerging community problems, prepared in accordance with the “Uniform requirements for submission to bio-medical journals” laid down by International Committee of Medical Journals Editors (ICMJE). All publications of JCPSP are peer reviewed by subject specialists from Pakistan and locally and abroad.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信