联合使用爪钩和椎板下钢丝作为骨质疏松病例胸椎至骨盆长固定的上基础的优势:近端接点应力的有限元分析。

IF 1.2 Q3 SURGERY
Spine Surgery and Related Research Pub Date : 2024-08-30 eCollection Date: 2025-03-27 DOI:10.22603/ssrr.2024-0169
Takuhei Kozaki, Takachika Shimizu, Akimasa Murata, Ryuichiro Nakanishi, Takahiro Kozaki, Ei Yamamoto, Shunji Tsutsui, Mamoru Kawakami, Hiroshi Yamada
{"title":"联合使用爪钩和椎板下钢丝作为骨质疏松病例胸椎至骨盆长固定的上基础的优势:近端接点应力的有限元分析。","authors":"Takuhei Kozaki, Takachika Shimizu, Akimasa Murata, Ryuichiro Nakanishi, Takahiro Kozaki, Ei Yamamoto, Shunji Tsutsui, Mamoru Kawakami, Hiroshi Yamada","doi":"10.22603/ssrr.2024-0169","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study aimed to compare the biomechanical stress at the proximal junctional aspect between the conventional pedicle screw (PS) fixation (PSF) and the low PS density fixation (LPF) method.</p><p><strong>Methods: </strong>This study involved 10 patients, half of whom have non-osteoporosis and the other half have osteoporosis. We made two types of intact models (one is from the upper thoracic-to-pelvis model, and the other is from the lower thoracic-to-pelvis model). From the intact models, we constructed two kinds of fusion models: (1) PSF and (2) LPF. The LPF method was as follows: The claw hooks (the combination of the down-going transverse process hooks and facet hooks) were set at the upper instrumented vertebra (UIV) and sublaminar wires at the thoracic spine and PSs at the lumbo-pelvis.</p><p><strong>Results: </strong><i>Upper thoracic to pelvis fixation model</i> In non-osteoporosis, no significant difference between the PSF and LPF is found. In osteoporosis, the von Mises stresses of the vertebra body at UIV, UIV+1, and disc were significantly lower in LPF than in PSF. <i>Lower thoracic-to-pelvis fixation model</i> In non-osteoporosis, the average von Mises stress of the vertebral body at UIV+1 and the maximum stress at UIV were lower in LPF than in PSF; however, no significant difference was found in the others. In osteoporosis, the von Mises stress was significantly lower in LPF than in PSF.</p><p><strong>Conclusions: </strong>The claw hooks stabilized the vertebra body at UIV firmly, and sublaminar wires reduced load translation from the fixed spine.</p>","PeriodicalId":22253,"journal":{"name":"Spine Surgery and Related Research","volume":"9 2","pages":"202-210"},"PeriodicalIF":1.2000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11983124/pdf/","citationCount":"0","resultStr":"{\"title\":\"Advantages of Combined Use of Claw Hooks and Sublaminar Wires as the Upper Foundation of Long Fixation from the Thoracic Spine to the Pelvis in Osteoporotic Cases: A Finite Element Analysis of Proximal Junction Stress.\",\"authors\":\"Takuhei Kozaki, Takachika Shimizu, Akimasa Murata, Ryuichiro Nakanishi, Takahiro Kozaki, Ei Yamamoto, Shunji Tsutsui, Mamoru Kawakami, Hiroshi Yamada\",\"doi\":\"10.22603/ssrr.2024-0169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>This study aimed to compare the biomechanical stress at the proximal junctional aspect between the conventional pedicle screw (PS) fixation (PSF) and the low PS density fixation (LPF) method.</p><p><strong>Methods: </strong>This study involved 10 patients, half of whom have non-osteoporosis and the other half have osteoporosis. We made two types of intact models (one is from the upper thoracic-to-pelvis model, and the other is from the lower thoracic-to-pelvis model). From the intact models, we constructed two kinds of fusion models: (1) PSF and (2) LPF. The LPF method was as follows: The claw hooks (the combination of the down-going transverse process hooks and facet hooks) were set at the upper instrumented vertebra (UIV) and sublaminar wires at the thoracic spine and PSs at the lumbo-pelvis.</p><p><strong>Results: </strong><i>Upper thoracic to pelvis fixation model</i> In non-osteoporosis, no significant difference between the PSF and LPF is found. In osteoporosis, the von Mises stresses of the vertebra body at UIV, UIV+1, and disc were significantly lower in LPF than in PSF. <i>Lower thoracic-to-pelvis fixation model</i> In non-osteoporosis, the average von Mises stress of the vertebral body at UIV+1 and the maximum stress at UIV were lower in LPF than in PSF; however, no significant difference was found in the others. In osteoporosis, the von Mises stress was significantly lower in LPF than in PSF.</p><p><strong>Conclusions: </strong>The claw hooks stabilized the vertebra body at UIV firmly, and sublaminar wires reduced load translation from the fixed spine.</p>\",\"PeriodicalId\":22253,\"journal\":{\"name\":\"Spine Surgery and Related Research\",\"volume\":\"9 2\",\"pages\":\"202-210\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11983124/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spine Surgery and Related Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22603/ssrr.2024-0169\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/27 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spine Surgery and Related Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22603/ssrr.2024-0169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/27 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

简介:本研究旨在比较传统椎弓根螺钉(PS)固定(PSF)和低PS密度固定(LPF)方法在近交界处的生物力学应力。方法:本研究纳入10例患者,其中一半为非骨质疏松症,另一半为骨质疏松症。我们制作了两种完整的模型(一种是上胸-骨盆模型,另一种是下胸-骨盆模型)。基于完整模型,我们构建了两种融合模型:(1)PSF和(2)LPF。LPF方法如下:将爪钩(下行横突钩和小面钩的组合)设置在上固定椎体(UIV)和胸椎的板下钉,将PSs设置在腰骨盆。结果:在非骨质疏松的情况下,PSF与LPF无显著性差异。骨质疏松症中,LPF椎体在UIV、UIV+1和椎间盘处的von Mises应力明显低于PSF。在非骨质疏松症中,LPF组椎体UIV+1时的平均von Mises应力和UIV时的最大应力均低于PSF组;然而,在其他方面没有发现显著差异。在骨质疏松症中,LPF组的von Mises应力明显低于PSF组。结论:爪钩牢固地稳定了UIV椎体,板下钢丝减少了固定脊柱的负荷平移。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Advantages of Combined Use of Claw Hooks and Sublaminar Wires as the Upper Foundation of Long Fixation from the Thoracic Spine to the Pelvis in Osteoporotic Cases: A Finite Element Analysis of Proximal Junction Stress.

Introduction: This study aimed to compare the biomechanical stress at the proximal junctional aspect between the conventional pedicle screw (PS) fixation (PSF) and the low PS density fixation (LPF) method.

Methods: This study involved 10 patients, half of whom have non-osteoporosis and the other half have osteoporosis. We made two types of intact models (one is from the upper thoracic-to-pelvis model, and the other is from the lower thoracic-to-pelvis model). From the intact models, we constructed two kinds of fusion models: (1) PSF and (2) LPF. The LPF method was as follows: The claw hooks (the combination of the down-going transverse process hooks and facet hooks) were set at the upper instrumented vertebra (UIV) and sublaminar wires at the thoracic spine and PSs at the lumbo-pelvis.

Results: Upper thoracic to pelvis fixation model In non-osteoporosis, no significant difference between the PSF and LPF is found. In osteoporosis, the von Mises stresses of the vertebra body at UIV, UIV+1, and disc were significantly lower in LPF than in PSF. Lower thoracic-to-pelvis fixation model In non-osteoporosis, the average von Mises stress of the vertebral body at UIV+1 and the maximum stress at UIV were lower in LPF than in PSF; however, no significant difference was found in the others. In osteoporosis, the von Mises stress was significantly lower in LPF than in PSF.

Conclusions: The claw hooks stabilized the vertebra body at UIV firmly, and sublaminar wires reduced load translation from the fixed spine.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
71
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信