Roberto Fratangelo, Francesco Lolli, Maenia Scarpino, Antonello Grippo
{"title":"急性神经系统护理中的即时脑电图:叙述性回顾。","authors":"Roberto Fratangelo, Francesco Lolli, Maenia Scarpino, Antonello Grippo","doi":"10.3390/neurolint17040048","DOIUrl":null,"url":null,"abstract":"<p><p>Point-of-care electroencephalography (POC-EEG) systems are rapid-access, reduced-montage devices designed to address the limitations of conventional EEG (conv-EEG), enabling faster neurophysiological assessment in acute settings. This review evaluates their clinical impact, diagnostic performance, and feasibility in non-convulsive status epilepticus (NCSE), traumatic brain injury (TBI), stroke, and delirium. A comprehensive search of Medline, Scopus, and Embase identified 69 studies assessing 15 devices. In suspected NCSE, POC-EEG facilitates rapid seizure detection and prompt diagnosis, making it particularly effective in time-sensitive and resource-limited settings. Its after-hours availability and telemedicine integration ensure continuous coverage. AI-assisted tools enhance interpretability and accessibility, enabling use by non-experts. Despite variability in accuracy, it supports triaging, improving management, treatment decisions and outcomes while reducing hospital stays, transfers, and costs. In TBI, POC-EEG-derived quantitative EEG (qEEG) indices reliably detect structural lesions, support triage, and minimize unnecessary CT scans. They also help assess concussion severity and predict recovery. For strokes, POC-EEG aids triage by detecting large vessel occlusions (LVOs) with high feasibility in hospital and prehospital settings. In delirium, spectral analysis and AI-assisted models enhance diagnostic accuracy, broadening its clinical applications. Although POC-EEG is a promising screening tool, challenges remain in diagnostic variability, technical limitations, and AI optimization, requiring further research.</p>","PeriodicalId":19130,"journal":{"name":"Neurology International","volume":"17 4","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12029912/pdf/","citationCount":"0","resultStr":"{\"title\":\"Point-of-Care Electroencephalography in Acute Neurological Care: A Narrative Review.\",\"authors\":\"Roberto Fratangelo, Francesco Lolli, Maenia Scarpino, Antonello Grippo\",\"doi\":\"10.3390/neurolint17040048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Point-of-care electroencephalography (POC-EEG) systems are rapid-access, reduced-montage devices designed to address the limitations of conventional EEG (conv-EEG), enabling faster neurophysiological assessment in acute settings. This review evaluates their clinical impact, diagnostic performance, and feasibility in non-convulsive status epilepticus (NCSE), traumatic brain injury (TBI), stroke, and delirium. A comprehensive search of Medline, Scopus, and Embase identified 69 studies assessing 15 devices. In suspected NCSE, POC-EEG facilitates rapid seizure detection and prompt diagnosis, making it particularly effective in time-sensitive and resource-limited settings. Its after-hours availability and telemedicine integration ensure continuous coverage. AI-assisted tools enhance interpretability and accessibility, enabling use by non-experts. Despite variability in accuracy, it supports triaging, improving management, treatment decisions and outcomes while reducing hospital stays, transfers, and costs. In TBI, POC-EEG-derived quantitative EEG (qEEG) indices reliably detect structural lesions, support triage, and minimize unnecessary CT scans. They also help assess concussion severity and predict recovery. For strokes, POC-EEG aids triage by detecting large vessel occlusions (LVOs) with high feasibility in hospital and prehospital settings. In delirium, spectral analysis and AI-assisted models enhance diagnostic accuracy, broadening its clinical applications. Although POC-EEG is a promising screening tool, challenges remain in diagnostic variability, technical limitations, and AI optimization, requiring further research.</p>\",\"PeriodicalId\":19130,\"journal\":{\"name\":\"Neurology International\",\"volume\":\"17 4\",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12029912/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neurology International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/neurolint17040048\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurology International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/neurolint17040048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Point-of-Care Electroencephalography in Acute Neurological Care: A Narrative Review.
Point-of-care electroencephalography (POC-EEG) systems are rapid-access, reduced-montage devices designed to address the limitations of conventional EEG (conv-EEG), enabling faster neurophysiological assessment in acute settings. This review evaluates their clinical impact, diagnostic performance, and feasibility in non-convulsive status epilepticus (NCSE), traumatic brain injury (TBI), stroke, and delirium. A comprehensive search of Medline, Scopus, and Embase identified 69 studies assessing 15 devices. In suspected NCSE, POC-EEG facilitates rapid seizure detection and prompt diagnosis, making it particularly effective in time-sensitive and resource-limited settings. Its after-hours availability and telemedicine integration ensure continuous coverage. AI-assisted tools enhance interpretability and accessibility, enabling use by non-experts. Despite variability in accuracy, it supports triaging, improving management, treatment decisions and outcomes while reducing hospital stays, transfers, and costs. In TBI, POC-EEG-derived quantitative EEG (qEEG) indices reliably detect structural lesions, support triage, and minimize unnecessary CT scans. They also help assess concussion severity and predict recovery. For strokes, POC-EEG aids triage by detecting large vessel occlusions (LVOs) with high feasibility in hospital and prehospital settings. In delirium, spectral analysis and AI-assisted models enhance diagnostic accuracy, broadening its clinical applications. Although POC-EEG is a promising screening tool, challenges remain in diagnostic variability, technical limitations, and AI optimization, requiring further research.