Grummons分析在三维面部不对称评价中的应用。

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Contemporary Clinical Dentistry Pub Date : 2025-01-01 Epub Date: 2025-03-25 DOI:10.4103/ccd.ccd_551_24
Sandhra T Madhu, Rahul D Prabha, N K Sapna Varma, V V Ajith
{"title":"Grummons分析在三维面部不对称评价中的应用。","authors":"Sandhra T Madhu, Rahul D Prabha, N K Sapna Varma, V V Ajith","doi":"10.4103/ccd.ccd_551_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The assessment of three-dimensional (3D) Grummons analysis of cone-beam computed tomography (CBCT) and computed tomography (CT) using Dolphin Software in comparison to conventional manual tracing technique using two-dimensional (2D) postero-anterior (PA) cephalogram has been evaluated in this study.</p><p><strong>Materials and methods: </strong>Pretreatment records of patients who underwent CBCT (<i>n</i> = 23) or CT (<i>n</i> = 23) scan were collected. 3D Grummons analysis of the CBCT and CT images were performed on Dolphin 11.9. In addition, PA cephalograms were reconstructed from these 3D data and Grummons 2D analysis was performed. The 2D PA cephalograms obtained were then printed on X-ray films for manual tracing. Intrarater correlation coefficient was calculated for assessing the reliability of the values obtained using 3D, 2D, and manual tracings and paired <i>t</i> test was used to test the significance of mean values.</p><p><strong>Results: </strong>The results from the comparison of 3D and 2D data analysis indicated inconsistencies in anteroposterior parameters, particularly evident when CBCT and CT. The results from CBCT measurements showed the highest reliability when comparing 3D with 2D (both digital and manual tracings). Moderate-to-good reliability was found in CT measurements at Co-MSR (right and left), J-MSR right, mx/m and midline deviation, Me-deviation, Co-Ag (right and left) when comparing 3D and 2D methods. Paired <i>t</i>-test showed significant difference (<i>P</i> < 0.05) in the measurements comparing between Dolphin 3D and manual using CBCT at Ag-MSR left, Co-MSR (right and left), J-MSR (right and left). Among the CT measurements obtained, Dolphin 3D versus 2D and 2D manual tracing was found to show significant difference in parameters; Co-MSR right, Co-MSR left, J-MSR left, Co-MSR left, Ag-Me right, Ag-Me left Co-Ag right, and L6-MSR left.</p><p><strong>Conclusions: </strong>The study results prove that the use of a single CBCT minimizes the radiation exposure as well as delivers a more accurate representation of 3D anatomical structures.</p>","PeriodicalId":10632,"journal":{"name":"Contemporary Clinical Dentistry","volume":"16 1","pages":"36-43"},"PeriodicalIF":0.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12014008/pdf/","citationCount":"0","resultStr":"{\"title\":\"Application of Grummons Analysis for the Three-dimensional Facial Asymmetry Assessment.\",\"authors\":\"Sandhra T Madhu, Rahul D Prabha, N K Sapna Varma, V V Ajith\",\"doi\":\"10.4103/ccd.ccd_551_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The assessment of three-dimensional (3D) Grummons analysis of cone-beam computed tomography (CBCT) and computed tomography (CT) using Dolphin Software in comparison to conventional manual tracing technique using two-dimensional (2D) postero-anterior (PA) cephalogram has been evaluated in this study.</p><p><strong>Materials and methods: </strong>Pretreatment records of patients who underwent CBCT (<i>n</i> = 23) or CT (<i>n</i> = 23) scan were collected. 3D Grummons analysis of the CBCT and CT images were performed on Dolphin 11.9. In addition, PA cephalograms were reconstructed from these 3D data and Grummons 2D analysis was performed. The 2D PA cephalograms obtained were then printed on X-ray films for manual tracing. Intrarater correlation coefficient was calculated for assessing the reliability of the values obtained using 3D, 2D, and manual tracings and paired <i>t</i> test was used to test the significance of mean values.</p><p><strong>Results: </strong>The results from the comparison of 3D and 2D data analysis indicated inconsistencies in anteroposterior parameters, particularly evident when CBCT and CT. The results from CBCT measurements showed the highest reliability when comparing 3D with 2D (both digital and manual tracings). Moderate-to-good reliability was found in CT measurements at Co-MSR (right and left), J-MSR right, mx/m and midline deviation, Me-deviation, Co-Ag (right and left) when comparing 3D and 2D methods. Paired <i>t</i>-test showed significant difference (<i>P</i> < 0.05) in the measurements comparing between Dolphin 3D and manual using CBCT at Ag-MSR left, Co-MSR (right and left), J-MSR (right and left). Among the CT measurements obtained, Dolphin 3D versus 2D and 2D manual tracing was found to show significant difference in parameters; Co-MSR right, Co-MSR left, J-MSR left, Co-MSR left, Ag-Me right, Ag-Me left Co-Ag right, and L6-MSR left.</p><p><strong>Conclusions: </strong>The study results prove that the use of a single CBCT minimizes the radiation exposure as well as delivers a more accurate representation of 3D anatomical structures.</p>\",\"PeriodicalId\":10632,\"journal\":{\"name\":\"Contemporary Clinical Dentistry\",\"volume\":\"16 1\",\"pages\":\"36-43\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12014008/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Contemporary Clinical Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ccd.ccd_551_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contemporary Clinical Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ccd.ccd_551_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究评估了使用Dolphin软件的锥形束计算机断层扫描(CBCT)和计算机断层扫描(CT)的三维(3D) Grummons分析与使用二维(2D)后前(PA)脑电图的传统手工追踪技术的比较。材料与方法:收集接受CBCT (n = 23)或CT (n = 23)扫描患者的预处理记录。对Dolphin 11.9的CBCT和CT图像进行三维Grummons分析。此外,根据这些三维数据重建PA脑电图,并进行Grummons二维分析。然后将获得的二维PA脑电图打印在x射线胶片上进行人工追踪。计算内部相关系数以评估使用3D、2D和手动跟踪获得的值的可靠性,并使用配对t检验来检验平均值的显著性。结果:三维和二维数据对比分析结果显示,正位参数不一致,尤其是CBCT和CT。CBCT测量结果显示,当比较3D和2D(数字和手动跟踪)时,CBCT测量结果的可靠性最高。在比较3D和2D方法时,CT测量的Co-MSR(右和左),J-MSR右,mx/m和中线偏差,Me-deviation, Co-Ag(右和左)具有中等到良好的可靠性。配对t检验显示,海豚3D与手工CBCT在Ag-MSR左、Co-MSR(右、左)、J-MSR(右、左)的测量值差异有统计学意义(P < 0.05)。在获得的CT测量中,Dolphin 3D与2D和2D手动追踪在参数上存在显著差异;右为Co-MSR,左为Co-MSR,左为J-MSR,左为Co-MSR,右为Ag-Me,左为Ag-Me,左为Co-Ag,左为L6-MSR。结论:研究结果证明,使用单台CBCT可以最大限度地减少辐射暴露,并提供更准确的三维解剖结构表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of Grummons Analysis for the Three-dimensional Facial Asymmetry Assessment.

Background: The assessment of three-dimensional (3D) Grummons analysis of cone-beam computed tomography (CBCT) and computed tomography (CT) using Dolphin Software in comparison to conventional manual tracing technique using two-dimensional (2D) postero-anterior (PA) cephalogram has been evaluated in this study.

Materials and methods: Pretreatment records of patients who underwent CBCT (n = 23) or CT (n = 23) scan were collected. 3D Grummons analysis of the CBCT and CT images were performed on Dolphin 11.9. In addition, PA cephalograms were reconstructed from these 3D data and Grummons 2D analysis was performed. The 2D PA cephalograms obtained were then printed on X-ray films for manual tracing. Intrarater correlation coefficient was calculated for assessing the reliability of the values obtained using 3D, 2D, and manual tracings and paired t test was used to test the significance of mean values.

Results: The results from the comparison of 3D and 2D data analysis indicated inconsistencies in anteroposterior parameters, particularly evident when CBCT and CT. The results from CBCT measurements showed the highest reliability when comparing 3D with 2D (both digital and manual tracings). Moderate-to-good reliability was found in CT measurements at Co-MSR (right and left), J-MSR right, mx/m and midline deviation, Me-deviation, Co-Ag (right and left) when comparing 3D and 2D methods. Paired t-test showed significant difference (P < 0.05) in the measurements comparing between Dolphin 3D and manual using CBCT at Ag-MSR left, Co-MSR (right and left), J-MSR (right and left). Among the CT measurements obtained, Dolphin 3D versus 2D and 2D manual tracing was found to show significant difference in parameters; Co-MSR right, Co-MSR left, J-MSR left, Co-MSR left, Ag-Me right, Ag-Me left Co-Ag right, and L6-MSR left.

Conclusions: The study results prove that the use of a single CBCT minimizes the radiation exposure as well as delivers a more accurate representation of 3D anatomical structures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Contemporary Clinical Dentistry
Contemporary Clinical Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.50
自引率
0.00%
发文量
52
审稿时长
23 weeks
期刊介绍: The journal Contemporary Clinical Dentistry (CCD) (Print ISSN: 0976-237X, E-ISSN:0976- 2361) is peer-reviewed journal published on behalf of Maharishi Markandeshwar University and issues are published quarterly in the last week of March, June, September and December. The Journal publishes Original research papers, clinical studies, case series strictly of clinical interest. Manuscripts are invited from all specialties of Dentistry i.e. Conservative dentistry and Endodontics, Dentofacial orthopedics and Orthodontics, Oral medicine and Radiology, Oral pathology, Oral surgery, Orodental diseases, Pediatric Dentistry, Periodontics, Clinical aspects of Public Health dentistry and Prosthodontics. Review articles are not accepted. Review, if published, will only be by invitation from eminent scholars and academicians of National and International repute in the field of Medical/Dental education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信