可变角度掌侧锁定钢板治疗桡骨远端骨折的临床放射学效果。

Pp Bhagat Singh, E Pradeep, J Daniel Jey Janeson, Kv Arun Kumar, Mohideen Sheik, Pragadeeshwaran Gopi
{"title":"可变角度掌侧锁定钢板治疗桡骨远端骨折的临床放射学效果。","authors":"Pp Bhagat Singh, E Pradeep, J Daniel Jey Janeson, Kv Arun Kumar, Mohideen Sheik, Pragadeeshwaran Gopi","doi":"10.13107/jocr.2025.v15.i04.5518","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Treatment of distal radius fractures (DRFs) has evolved throughout time. The current management practices typically entail the use of locking compression plates. The inclusion of locking plates with variable angle options made it easier for surgeons to handle comminuted fracture fragments. This study examines the functional and radiological results of DRFs treated using a variable angle locking compression plate.</p><p><strong>Materials and methods: </strong>Between July 2022 and May 2024, a cohort of 25 patients with DRFs presented to the Department of Orthopaedics and was preoperatively examined before undergoing surgery with variable angle locking plates. They were followed up on a regular basis for a year after surgery, with the clinical and radiological outcomes assessed using the Modified Mayo Wrist Score.</p><p><strong>Results: </strong>Only two fractures failed to unite within a period of 4 months. The average range of motion was slightly restricted in comparison to the normal wrist. The mean grip strength after 1 year was 17.84 ± 6.05 kg. Merely 12% of individuals developed complications that were successfully addressed with conservative management. Approximately 72% (18 patients) of the patients achieved excellent results, whereas 24% (6 patients) had good outcomes, and approximately 4% (1 patient) had fair outcomes. The mean MMWS score at the end of 1 year was 91 ± 6.61.</p><p><strong>Conclusion: </strong>The utilization of variable-angle locking plates has been associated with excellent to good functional outcomes with very few complications.</p>","PeriodicalId":16647,"journal":{"name":"Journal of Orthopaedic Case Reports","volume":"15 4","pages":"270-276"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11981525/pdf/","citationCount":"0","resultStr":"{\"title\":\"Clinicoradiological Outcome of Variable Angle Volar Locking Plate in the Management of Distal Radius Fractures.\",\"authors\":\"Pp Bhagat Singh, E Pradeep, J Daniel Jey Janeson, Kv Arun Kumar, Mohideen Sheik, Pragadeeshwaran Gopi\",\"doi\":\"10.13107/jocr.2025.v15.i04.5518\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Treatment of distal radius fractures (DRFs) has evolved throughout time. The current management practices typically entail the use of locking compression plates. The inclusion of locking plates with variable angle options made it easier for surgeons to handle comminuted fracture fragments. This study examines the functional and radiological results of DRFs treated using a variable angle locking compression plate.</p><p><strong>Materials and methods: </strong>Between July 2022 and May 2024, a cohort of 25 patients with DRFs presented to the Department of Orthopaedics and was preoperatively examined before undergoing surgery with variable angle locking plates. They were followed up on a regular basis for a year after surgery, with the clinical and radiological outcomes assessed using the Modified Mayo Wrist Score.</p><p><strong>Results: </strong>Only two fractures failed to unite within a period of 4 months. The average range of motion was slightly restricted in comparison to the normal wrist. The mean grip strength after 1 year was 17.84 ± 6.05 kg. Merely 12% of individuals developed complications that were successfully addressed with conservative management. Approximately 72% (18 patients) of the patients achieved excellent results, whereas 24% (6 patients) had good outcomes, and approximately 4% (1 patient) had fair outcomes. The mean MMWS score at the end of 1 year was 91 ± 6.61.</p><p><strong>Conclusion: </strong>The utilization of variable-angle locking plates has been associated with excellent to good functional outcomes with very few complications.</p>\",\"PeriodicalId\":16647,\"journal\":{\"name\":\"Journal of Orthopaedic Case Reports\",\"volume\":\"15 4\",\"pages\":\"270-276\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11981525/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.13107/jocr.2025.v15.i04.5518\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13107/jocr.2025.v15.i04.5518","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

导读:桡骨远端骨折(DRFs)的治疗随着时间的推移而发展。目前的管理实践通常需要使用锁定压缩板。可变角度锁定钢板使外科医生更容易处理粉碎性骨折碎片。本研究探讨了可变角度锁定加压钢板治疗DRFs的功能和放射学结果。材料和方法:在2022年7月至2024年5月期间,一组25例DRFs患者在骨科就诊,术前接受可变角度锁定钢板手术检查。他们在手术后定期随访一年,使用改良梅奥手腕评分评估临床和放射学结果。结果:仅有2例骨折在4个月内未愈合。与正常手腕相比,平均活动范围略受限制。1年后平均握力为17.84±6.05 kg。只有12%的患者出现并发症,并通过保守治疗得以成功解决。约72%(18例)的患者获得了优异的结果,而24%(6例)的患者获得了良好的结果,约4%(1例)的患者获得了一般的结果。1年后MMWS平均评分为91±6.61。结论:使用可变角度锁定钢板可获得良好的功能效果,并发症少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clinicoradiological Outcome of Variable Angle Volar Locking Plate in the Management of Distal Radius Fractures.

Introduction: Treatment of distal radius fractures (DRFs) has evolved throughout time. The current management practices typically entail the use of locking compression plates. The inclusion of locking plates with variable angle options made it easier for surgeons to handle comminuted fracture fragments. This study examines the functional and radiological results of DRFs treated using a variable angle locking compression plate.

Materials and methods: Between July 2022 and May 2024, a cohort of 25 patients with DRFs presented to the Department of Orthopaedics and was preoperatively examined before undergoing surgery with variable angle locking plates. They were followed up on a regular basis for a year after surgery, with the clinical and radiological outcomes assessed using the Modified Mayo Wrist Score.

Results: Only two fractures failed to unite within a period of 4 months. The average range of motion was slightly restricted in comparison to the normal wrist. The mean grip strength after 1 year was 17.84 ± 6.05 kg. Merely 12% of individuals developed complications that were successfully addressed with conservative management. Approximately 72% (18 patients) of the patients achieved excellent results, whereas 24% (6 patients) had good outcomes, and approximately 4% (1 patient) had fair outcomes. The mean MMWS score at the end of 1 year was 91 ± 6.61.

Conclusion: The utilization of variable-angle locking plates has been associated with excellent to good functional outcomes with very few complications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
128
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信