评估优化的短乳房和全乳房MRI方案在筛查中高风险妇女乳腺癌中的解读器一致性。

IF 2.1 4区 医学 Q2 OBSTETRICS & GYNECOLOGY
Breast Care Pub Date : 2025-03-05 DOI:10.1159/000543958
Agnaldo Lopes da Silva Filho, Mariana Mitraud Ottoni Guedes, Thais Paiva Moraes, Adriene Moraes Campos, Ivie Braga de Paula, Felipe Marcondes de Oliveira Coelho, Barbara Silveira Santana, Bertha Andrade Coelho, Letícia Martins de Araújo Campos Linhares, Henrique Lima Couto
{"title":"评估优化的短乳房和全乳房MRI方案在筛查中高风险妇女乳腺癌中的解读器一致性。","authors":"Agnaldo Lopes da Silva Filho, Mariana Mitraud Ottoni Guedes, Thais Paiva Moraes, Adriene Moraes Campos, Ivie Braga de Paula, Felipe Marcondes de Oliveira Coelho, Barbara Silveira Santana, Bertha Andrade Coelho, Letícia Martins de Araújo Campos Linhares, Henrique Lima Couto","doi":"10.1159/000543958","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The optimized short breast MRI protocol for breast cancer screening was developed to address some limitations of the complete protocol, such as long examination duration and high cost. This study aimed to evaluate the intraobserver agreement between optimized short and complete protocols in the interpretation of breast MRI images. Specifically, we assessed the acquisition and reading times of the images, as well as the time required for report generation.</p><p><strong>Methods: </strong>A cross-sectional study was conducted in asymptomatic women with high breast density, at moderate and high risk, who underwent breast MRI in private institutions in Belo Horizonte, MG, Brazil. An optimized short protocol was simulated on a computer by selecting images from the complete examination. The examinations were read independently, with BI-RADS categories assigned. Intraobserver agreement between this shorter protocol and the complete protocol was assessed.</p><p><strong>Results: </strong>A total of 170 women were included. A 100% BI-RADS agreement rate was observed in categories 1 and 2, an 80.95% agreement rate in category 3, and a 93.75% agreement rate in category 4 between the protocols. The unweighted kappa value was 0.955 (95% confidence interval [CI] 0.916-0.993), while the weighted kappa value was 0.969 (95% CI: 0.943-0.995). Furthermore, the optimized short protocol reduced examination duration by 21 min.</p><p><strong>Conclusion: </strong>The optimized short breast MRI protocol provides a time-efficient alternative for breast cancer screening in moderate- to high-risk populations with dense breasts while maintaining strong agreement in BI-RADS classification. This protocol reduces costs and enhances patient tolerability, thereby improving accessibility to breast MRI.</p>","PeriodicalId":9310,"journal":{"name":"Breast Care","volume":" ","pages":"1-7"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11981293/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Interreader Agreement between Optimized Short and Full Breast MRI Protocols for Screening Breast Cancer in Moderate- and High-Risk Women.\",\"authors\":\"Agnaldo Lopes da Silva Filho, Mariana Mitraud Ottoni Guedes, Thais Paiva Moraes, Adriene Moraes Campos, Ivie Braga de Paula, Felipe Marcondes de Oliveira Coelho, Barbara Silveira Santana, Bertha Andrade Coelho, Letícia Martins de Araújo Campos Linhares, Henrique Lima Couto\",\"doi\":\"10.1159/000543958\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The optimized short breast MRI protocol for breast cancer screening was developed to address some limitations of the complete protocol, such as long examination duration and high cost. This study aimed to evaluate the intraobserver agreement between optimized short and complete protocols in the interpretation of breast MRI images. Specifically, we assessed the acquisition and reading times of the images, as well as the time required for report generation.</p><p><strong>Methods: </strong>A cross-sectional study was conducted in asymptomatic women with high breast density, at moderate and high risk, who underwent breast MRI in private institutions in Belo Horizonte, MG, Brazil. An optimized short protocol was simulated on a computer by selecting images from the complete examination. The examinations were read independently, with BI-RADS categories assigned. Intraobserver agreement between this shorter protocol and the complete protocol was assessed.</p><p><strong>Results: </strong>A total of 170 women were included. A 100% BI-RADS agreement rate was observed in categories 1 and 2, an 80.95% agreement rate in category 3, and a 93.75% agreement rate in category 4 between the protocols. The unweighted kappa value was 0.955 (95% confidence interval [CI] 0.916-0.993), while the weighted kappa value was 0.969 (95% CI: 0.943-0.995). Furthermore, the optimized short protocol reduced examination duration by 21 min.</p><p><strong>Conclusion: </strong>The optimized short breast MRI protocol provides a time-efficient alternative for breast cancer screening in moderate- to high-risk populations with dense breasts while maintaining strong agreement in BI-RADS classification. This protocol reduces costs and enhances patient tolerability, thereby improving accessibility to breast MRI.</p>\",\"PeriodicalId\":9310,\"journal\":{\"name\":\"Breast Care\",\"volume\":\" \",\"pages\":\"1-7\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11981293/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Breast Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000543958\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Breast Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000543958","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

针对完整方案存在的检查时间长、费用高的局限性,开发了优化的乳腺MRI短方案用于乳腺癌筛查。本研究旨在评估在乳腺MRI图像解释中,优化的短协议和完整协议在观察者内的一致性。具体来说,我们评估了图像的获取和阅读时间,以及生成报告所需的时间。方法:对在巴西MG贝洛奥里藏特私立机构接受乳腺MRI检查的无症状、高乳腺密度、中、高风险女性进行横断面研究。从完整的检查中选择图像,在计算机上模拟优化的短协议。考试是独立阅读的,并分配了BI-RADS类别。评估了这个较短的方案和完整的方案之间的观察员内部一致性。结果:共纳入170名女性。在1类和2类中观察到100%的BI-RADS一致性,在3类中观察到80.95%的一致性,在4类中观察到93.75%的一致性。未加权kappa值为0.955(95%可信区间[CI] 0.916 ~ 0.993),加权kappa值为0.969 (95% CI: 0.943 ~ 0.995)。此外,优化后的短方案将检查时间缩短了21分钟。结论:优化后的短乳房MRI方案在BI-RADS分类保持高度一致的同时,为乳腺致密的中高风险人群提供了一种高效的乳腺癌筛查替代方案。该方案降低了成本,提高了患者的耐受性,从而提高了乳房MRI的可及性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Interreader Agreement between Optimized Short and Full Breast MRI Protocols for Screening Breast Cancer in Moderate- and High-Risk Women.

Introduction: The optimized short breast MRI protocol for breast cancer screening was developed to address some limitations of the complete protocol, such as long examination duration and high cost. This study aimed to evaluate the intraobserver agreement between optimized short and complete protocols in the interpretation of breast MRI images. Specifically, we assessed the acquisition and reading times of the images, as well as the time required for report generation.

Methods: A cross-sectional study was conducted in asymptomatic women with high breast density, at moderate and high risk, who underwent breast MRI in private institutions in Belo Horizonte, MG, Brazil. An optimized short protocol was simulated on a computer by selecting images from the complete examination. The examinations were read independently, with BI-RADS categories assigned. Intraobserver agreement between this shorter protocol and the complete protocol was assessed.

Results: A total of 170 women were included. A 100% BI-RADS agreement rate was observed in categories 1 and 2, an 80.95% agreement rate in category 3, and a 93.75% agreement rate in category 4 between the protocols. The unweighted kappa value was 0.955 (95% confidence interval [CI] 0.916-0.993), while the weighted kappa value was 0.969 (95% CI: 0.943-0.995). Furthermore, the optimized short protocol reduced examination duration by 21 min.

Conclusion: The optimized short breast MRI protocol provides a time-efficient alternative for breast cancer screening in moderate- to high-risk populations with dense breasts while maintaining strong agreement in BI-RADS classification. This protocol reduces costs and enhances patient tolerability, thereby improving accessibility to breast MRI.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Breast Care
Breast Care 医学-妇产科学
CiteScore
4.40
自引率
4.80%
发文量
45
审稿时长
6-12 weeks
期刊介绍: ''Breast Care'' is a peer-reviewed scientific journal that covers all aspects of breast biology. Due to its interdisciplinary perspective, it encompasses articles on basic research, prevention, diagnosis, and treatment of malignant diseases of the breast. In addition to presenting current developments in clinical research, the scope of clinical practice is broadened by including articles on relevant legal, financial and economic issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信