利用活化部分凝血酶时间和凝血酶原时间评价新鲜冷冻血浆的质量。

IF 1.8 4区 医学 Q3 HEMATOLOGY
International Journal of Hematology Pub Date : 2025-09-01 Epub Date: 2025-04-12 DOI:10.1007/s12185-025-03984-4
Yao Layibo, Essohana Padaro, Hèzouwè Magnang, Magnime Badassan, Irenée M D Kuéviakoé, Koffi Mawussi, Lochina Fétéké
{"title":"利用活化部分凝血酶时间和凝血酶原时间评价新鲜冷冻血浆的质量。","authors":"Yao Layibo, Essohana Padaro, Hèzouwè Magnang, Magnime Badassan, Irenée M D Kuéviakoé, Koffi Mawussi, Lochina Fétéké","doi":"10.1007/s12185-025-03984-4","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate the usefulness of activated partial thromboplastin time (APTT) and prothrombin time (PT) for determining the quality of fresh frozen plasma (FFP) units in low-income countries. Quality control was conducted for 66 randomly selected FFP units after 3 months of freezing at - 20 °C. The average volume of the FFP units was 177.8 ± 17.3 mL, with average concentrations of 79.9 ± 40.2 IU/dL for factor VIII, 83.4 ± 29.3 IU/dL for factor IX, and 2.3 ± 0.7 g/L for fibrinogen. Fifty-six percent of the FFP units had a factor VIII level greater than or equal to 70 IU/dL. Unlike PT, the PT ratio, and the international normalized ratio, both APTT and the APTT ratio provided useful information regarding factor VIII level compliance, with areas under the curve of 71% and 73%, respectively. The optimal cutoff values for FFP unit compliance assessment were 40 s for APTT and 1.23 for the APTT ratio. Accuracy rates were 65% and 70%, with Cohen's kappa coefficients of 0.31 and 0.40 for the APTT and APTT ratios, respectively. APTT outperformed PT, and showed fair to moderate agreement with factor VIII level compliance in FFP units.</p>","PeriodicalId":13992,"journal":{"name":"International Journal of Hematology","volume":" ","pages":"392-399"},"PeriodicalIF":1.8000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of activated partial thrombin time and prothrombin time for quality assessment of fresh frozen plasma.\",\"authors\":\"Yao Layibo, Essohana Padaro, Hèzouwè Magnang, Magnime Badassan, Irenée M D Kuéviakoé, Koffi Mawussi, Lochina Fétéké\",\"doi\":\"10.1007/s12185-025-03984-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to evaluate the usefulness of activated partial thromboplastin time (APTT) and prothrombin time (PT) for determining the quality of fresh frozen plasma (FFP) units in low-income countries. Quality control was conducted for 66 randomly selected FFP units after 3 months of freezing at - 20 °C. The average volume of the FFP units was 177.8 ± 17.3 mL, with average concentrations of 79.9 ± 40.2 IU/dL for factor VIII, 83.4 ± 29.3 IU/dL for factor IX, and 2.3 ± 0.7 g/L for fibrinogen. Fifty-six percent of the FFP units had a factor VIII level greater than or equal to 70 IU/dL. Unlike PT, the PT ratio, and the international normalized ratio, both APTT and the APTT ratio provided useful information regarding factor VIII level compliance, with areas under the curve of 71% and 73%, respectively. The optimal cutoff values for FFP unit compliance assessment were 40 s for APTT and 1.23 for the APTT ratio. Accuracy rates were 65% and 70%, with Cohen's kappa coefficients of 0.31 and 0.40 for the APTT and APTT ratios, respectively. APTT outperformed PT, and showed fair to moderate agreement with factor VIII level compliance in FFP units.</p>\",\"PeriodicalId\":13992,\"journal\":{\"name\":\"International Journal of Hematology\",\"volume\":\" \",\"pages\":\"392-399\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Hematology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s12185-025-03984-4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/4/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Hematology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12185-025-03984-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是评估激活部分凝血活素时间(APTT)和凝血酶原时间(PT)在确定低收入国家新鲜冷冻血浆(FFP)单位质量方面的有用性。随机选择66个FFP单位在- 20°C冷冻3个月后进行质量控制。FFP单位平均容积为177.8±17.3 mL,因子VIII平均浓度为79.9±40.2 IU/dL,因子IX平均浓度为83.4±29.3 IU/dL,纤维蛋白原平均浓度为2.3±0.7 g/L。56%的FFP单位的因子VIII水平大于或等于70 IU/dL。与PT、PT比率和国际标准化比率不同,APTT和APTT比率都提供了有关因子VIII水平依从性的有用信息,曲线下面积分别为71%和73%。APTT和APTT比值的最佳临界值分别为40 s和1.23 s。准确率分别为65%和70%,APTT和APTT比值的Cohen’s kappa系数分别为0.31和0.40。APTT优于PT,并与FFP单位的因子VIII水平依从性显示出公平至中等的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Use of activated partial thrombin time and prothrombin time for quality assessment of fresh frozen plasma.

The aim of this study was to evaluate the usefulness of activated partial thromboplastin time (APTT) and prothrombin time (PT) for determining the quality of fresh frozen plasma (FFP) units in low-income countries. Quality control was conducted for 66 randomly selected FFP units after 3 months of freezing at - 20 °C. The average volume of the FFP units was 177.8 ± 17.3 mL, with average concentrations of 79.9 ± 40.2 IU/dL for factor VIII, 83.4 ± 29.3 IU/dL for factor IX, and 2.3 ± 0.7 g/L for fibrinogen. Fifty-six percent of the FFP units had a factor VIII level greater than or equal to 70 IU/dL. Unlike PT, the PT ratio, and the international normalized ratio, both APTT and the APTT ratio provided useful information regarding factor VIII level compliance, with areas under the curve of 71% and 73%, respectively. The optimal cutoff values for FFP unit compliance assessment were 40 s for APTT and 1.23 for the APTT ratio. Accuracy rates were 65% and 70%, with Cohen's kappa coefficients of 0.31 and 0.40 for the APTT and APTT ratios, respectively. APTT outperformed PT, and showed fair to moderate agreement with factor VIII level compliance in FFP units.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
4.80%
发文量
223
审稿时长
6 months
期刊介绍: The International Journal of Hematology, the official journal of the Japanese Society of Hematology, has a long history of publishing leading research in hematology. The journal comprises articles that contribute to progress in research not only in basic hematology but also in clinical hematology, aiming to cover all aspects of this field, namely, erythrocytes, leukocytes and hematopoiesis, hemostasis, thrombosis and vascular biology, hematological malignancies, transplantation, and cell therapy. The expanded [Progress in Hematology] section integrates such relevant fields as the cell biology of stem cells and cancer cells, and clinical research in inflammation, cancer, and thrombosis. Reports on results of clinical trials are also included, thus contributing to the aim of fostering communication among researchers in the growing field of modern hematology. The journal provides the best of up-to-date information on modern hematology, presenting readers with high-impact, original work focusing on pivotal issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信