消融指数引导下心房颤动射频消融与蒸汽爆相关的消融特征。

IF 7.9 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Europace Pub Date : 2025-03-28 DOI:10.1093/europace/euaf084
Xue-Si Wang, Ze-Yang Wu, Qi Wu, De-Yong Long, Cai-Hua Sang, Chen-Xi Jiang, Wei Wang, Xin Zhao, Chang-Yi Li, Rong-Hui Yu, Nian Liu, Song-Nan Li, Xiao-Xia Liu, Xue-Yuan Guo, Song Zuo, Meng-Meng Li, Tong Liu, Wen-Li Dai, Ming-Yang Gao, Chang-Qi Jia, Man Ning, Li Feng, Wen-He Lv, Yu-Kun Li, Xiao-Ying Liu, Zhuo-Hang Du, Jia-Lin Li, Xin-Ru Li, Jian-Zeng Dong, Chang-Sheng Ma, Ri-Bo Tang
{"title":"消融指数引导下心房颤动射频消融与蒸汽爆相关的消融特征。","authors":"Xue-Si Wang, Ze-Yang Wu, Qi Wu, De-Yong Long, Cai-Hua Sang, Chen-Xi Jiang, Wei Wang, Xin Zhao, Chang-Yi Li, Rong-Hui Yu, Nian Liu, Song-Nan Li, Xiao-Xia Liu, Xue-Yuan Guo, Song Zuo, Meng-Meng Li, Tong Liu, Wen-Li Dai, Ming-Yang Gao, Chang-Qi Jia, Man Ning, Li Feng, Wen-He Lv, Yu-Kun Li, Xiao-Ying Liu, Zhuo-Hang Du, Jia-Lin Li, Xin-Ru Li, Jian-Zeng Dong, Chang-Sheng Ma, Ri-Bo Tang","doi":"10.1093/europace/euaf084","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Steam pops present a significant concern during radiofrequency (RF) ablation of atrial fibrillation (AF). It is crucial to analyse the incidence and ablation characteristics associated with steam pops. This study aims to investigate the occurrence and potential predictors of steam pops.</p><p><strong>Methods and results: </strong>This study included 3263 patients with AF who underwent RF ablation. Patients with paroxysmal AF received bilateral circumferential pulmonary vein (PV) ablation, while those with persistent AF underwent additional linear ablation. The ablation parameters at the sites of steam pops were compared to those at adjacent anatomical locations. A total of 81 steam pops (2.5%) with one pericardial tamponade were recorded. Steam pops were observed at liner ablation sites: 6 (0.4%) at the mitral isthmus, 16 (0.9%) at the tricuspid isthmus (CTI), and 7 (0.5%) along the roofline. The most common sites of steam pops were the anterior edge of the left superior PV and the inferior vena cava side of the CTI. The impedance drop was significantly higher (18.2 ± 9.5 Ω vs. 13.5 ± 4.8 Ω, P < 0.001) at steam pop sites. The optimal cut-off points of impedance drop for predicting steam pops were > 9.5 Ω within the first 3 s, > 10.5 Ω within the first 5 s, > 13.5 Ω within the first 10 s, and > 18.5 Ω in the whole ablation, respectively.</p><p><strong>Conclusion: </strong>The incidence of steam pops during ablation of AF is infrequent. Impedance drop is the only ablation parameter that could predict the occurrence of steam pops.</p>","PeriodicalId":11981,"journal":{"name":"Europace","volume":" ","pages":""},"PeriodicalIF":7.9000,"publicationDate":"2025-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12019224/pdf/","citationCount":"0","resultStr":"{\"title\":\"Ablation characteristics associated with steam pops in ablation index-guided radiofrequency ablation of atrial fibrillation.\",\"authors\":\"Xue-Si Wang, Ze-Yang Wu, Qi Wu, De-Yong Long, Cai-Hua Sang, Chen-Xi Jiang, Wei Wang, Xin Zhao, Chang-Yi Li, Rong-Hui Yu, Nian Liu, Song-Nan Li, Xiao-Xia Liu, Xue-Yuan Guo, Song Zuo, Meng-Meng Li, Tong Liu, Wen-Li Dai, Ming-Yang Gao, Chang-Qi Jia, Man Ning, Li Feng, Wen-He Lv, Yu-Kun Li, Xiao-Ying Liu, Zhuo-Hang Du, Jia-Lin Li, Xin-Ru Li, Jian-Zeng Dong, Chang-Sheng Ma, Ri-Bo Tang\",\"doi\":\"10.1093/europace/euaf084\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>Steam pops present a significant concern during radiofrequency (RF) ablation of atrial fibrillation (AF). It is crucial to analyse the incidence and ablation characteristics associated with steam pops. This study aims to investigate the occurrence and potential predictors of steam pops.</p><p><strong>Methods and results: </strong>This study included 3263 patients with AF who underwent RF ablation. Patients with paroxysmal AF received bilateral circumferential pulmonary vein (PV) ablation, while those with persistent AF underwent additional linear ablation. The ablation parameters at the sites of steam pops were compared to those at adjacent anatomical locations. A total of 81 steam pops (2.5%) with one pericardial tamponade were recorded. Steam pops were observed at liner ablation sites: 6 (0.4%) at the mitral isthmus, 16 (0.9%) at the tricuspid isthmus (CTI), and 7 (0.5%) along the roofline. The most common sites of steam pops were the anterior edge of the left superior PV and the inferior vena cava side of the CTI. The impedance drop was significantly higher (18.2 ± 9.5 Ω vs. 13.5 ± 4.8 Ω, P < 0.001) at steam pop sites. The optimal cut-off points of impedance drop for predicting steam pops were > 9.5 Ω within the first 3 s, > 10.5 Ω within the first 5 s, > 13.5 Ω within the first 10 s, and > 18.5 Ω in the whole ablation, respectively.</p><p><strong>Conclusion: </strong>The incidence of steam pops during ablation of AF is infrequent. Impedance drop is the only ablation parameter that could predict the occurrence of steam pops.</p>\",\"PeriodicalId\":11981,\"journal\":{\"name\":\"Europace\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":7.9000,\"publicationDate\":\"2025-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12019224/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Europace\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/europace/euaf084\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Europace","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/europace/euaf084","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:在心房颤动(AF)的射频消融过程中,蒸汽爆裂是一个重要的问题。分析与汽爆有关的入射和烧蚀特性是至关重要的。目的:本研究旨在探讨蒸汽爆点的发生和潜在的预测因素。方法:本研究纳入3263例接受射频消融治疗的房颤患者。阵发性房颤患者接受双侧环肺静脉消融,而持续性房颤患者接受额外的线性消融。将蒸汽爆点处的消融参数与邻近解剖位置的消融参数进行比较。结果:共记录蒸汽爆81例(2.5%),心包填塞1例。在直线消融部位观察到蒸汽爆:二尖瓣峡6例(0.4%),三尖瓣峡16例(0.9%),顶线7例(0.5%)。最常见的部位为左上肺静脉前缘和三尖峡下腔静脉侧。在蒸汽爆点处阻抗下降明显更高(18.2±9.5 Ω vs. 13.5±4.8 Ω, p < 0.001)。在整个烧蚀过程中,阻抗降预测蒸汽爆点的最佳截止点分别为:前3秒内> 9.5 Ω、前5秒内> 10.5 Ω、前10秒内> 13.5 Ω和> 18.5 Ω。结论:房颤消融过程中蒸汽爆的发生率较低。阻抗降是唯一能预测汽爆发生的烧蚀参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ablation characteristics associated with steam pops in ablation index-guided radiofrequency ablation of atrial fibrillation.

Aims: Steam pops present a significant concern during radiofrequency (RF) ablation of atrial fibrillation (AF). It is crucial to analyse the incidence and ablation characteristics associated with steam pops. This study aims to investigate the occurrence and potential predictors of steam pops.

Methods and results: This study included 3263 patients with AF who underwent RF ablation. Patients with paroxysmal AF received bilateral circumferential pulmonary vein (PV) ablation, while those with persistent AF underwent additional linear ablation. The ablation parameters at the sites of steam pops were compared to those at adjacent anatomical locations. A total of 81 steam pops (2.5%) with one pericardial tamponade were recorded. Steam pops were observed at liner ablation sites: 6 (0.4%) at the mitral isthmus, 16 (0.9%) at the tricuspid isthmus (CTI), and 7 (0.5%) along the roofline. The most common sites of steam pops were the anterior edge of the left superior PV and the inferior vena cava side of the CTI. The impedance drop was significantly higher (18.2 ± 9.5 Ω vs. 13.5 ± 4.8 Ω, P < 0.001) at steam pop sites. The optimal cut-off points of impedance drop for predicting steam pops were > 9.5 Ω within the first 3 s, > 10.5 Ω within the first 5 s, > 13.5 Ω within the first 10 s, and > 18.5 Ω in the whole ablation, respectively.

Conclusion: The incidence of steam pops during ablation of AF is infrequent. Impedance drop is the only ablation parameter that could predict the occurrence of steam pops.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Europace
Europace 医学-心血管系统
CiteScore
10.30
自引率
8.20%
发文量
851
审稿时长
3-6 weeks
期刊介绍: EP - Europace - European Journal of Pacing, Arrhythmias and Cardiac Electrophysiology of the European Heart Rhythm Association of the European Society of Cardiology. The journal aims to provide an avenue of communication of top quality European and international original scientific work and reviews in the fields of Arrhythmias, Pacing and Cellular Electrophysiology. The Journal offers the reader a collection of contemporary original peer-reviewed papers, invited papers and editorial comments together with book reviews and correspondence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信