基于翻转过滤法的傅立叶变换离子回旋共振质谱(FT-ICR MS)碰撞截面测量法

IF 1.9 3区 化学 Q3 BIOCHEMICAL RESEARCH METHODS
Dayu Li, Zhiwei Wang, Yanying Fan, Wei Xu
{"title":"基于翻转过滤法的傅立叶变换离子回旋共振质谱(FT-ICR MS)碰撞截面测量法","authors":"Dayu Li,&nbsp;Zhiwei Wang,&nbsp;Yanying Fan,&nbsp;Wei Xu","doi":"10.1002/jms.5136","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>The ion collision cross section (CCS) is closely related to the structural and physical conformation of compounds, making it an ideal parameter for constructing databases. In recent years, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) has gained widespread application in CCS measurements thanks to its ultra-high mass resolution and accuracy. Due to the collisions between ions and neutral molecules within the FT-ICR MS cell, the image current decays. Based on this feature, the ion CCS can be precisely calculated by applying corresponding collision models and algorithms. A new time-frequency analysis method is introduced: the flipping-filtering method based on the Levenberg–Marquardt algorithm. Before filtering, the data undergoes flipping and extension, effectively mitigating the issue of signal point waste commonly associated with traditional filtering techniques. This approach ensures a smooth and uninterrupted envelope of the image current signal while significantly enhancing the accuracy of decay factor and ion CCS measurements. Compared to the linewidth correction method and the line shape fitting method, this method exhibits superior noise resistance and resolution capabilities, serving as a valuable adjunct to ion CCS measurement techniques.</p>\n </div>","PeriodicalId":16178,"journal":{"name":"Journal of Mass Spectrometry","volume":"60 5","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Collision Cross Section Measurements in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) Based on the Flipping-Filtering Method\",\"authors\":\"Dayu Li,&nbsp;Zhiwei Wang,&nbsp;Yanying Fan,&nbsp;Wei Xu\",\"doi\":\"10.1002/jms.5136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>The ion collision cross section (CCS) is closely related to the structural and physical conformation of compounds, making it an ideal parameter for constructing databases. In recent years, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) has gained widespread application in CCS measurements thanks to its ultra-high mass resolution and accuracy. Due to the collisions between ions and neutral molecules within the FT-ICR MS cell, the image current decays. Based on this feature, the ion CCS can be precisely calculated by applying corresponding collision models and algorithms. A new time-frequency analysis method is introduced: the flipping-filtering method based on the Levenberg–Marquardt algorithm. Before filtering, the data undergoes flipping and extension, effectively mitigating the issue of signal point waste commonly associated with traditional filtering techniques. This approach ensures a smooth and uninterrupted envelope of the image current signal while significantly enhancing the accuracy of decay factor and ion CCS measurements. Compared to the linewidth correction method and the line shape fitting method, this method exhibits superior noise resistance and resolution capabilities, serving as a valuable adjunct to ion CCS measurement techniques.</p>\\n </div>\",\"PeriodicalId\":16178,\"journal\":{\"name\":\"Journal of Mass Spectrometry\",\"volume\":\"60 5\",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jms.5136\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jms.5136","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

离子碰撞截面(CCS)与化合物的结构和物理构象密切相关,是构建数据库的理想参数。近年来,傅里叶变换离子回旋共振质谱(FT-ICR MS)以其超高的质量分辨率和精度在CCS测量中得到了广泛的应用。由于离子和中性分子在FT-ICR质谱电池内的碰撞,图像电流衰减。基于这一特征,可以应用相应的碰撞模型和算法精确计算离子CCS。介绍了一种新的时频分析方法:基于Levenberg-Marquardt算法的翻转滤波方法。在滤波之前,数据经过翻转和扩展,有效地减轻了传统滤波技术中常见的信号点浪费问题。这种方法确保了图像电流信号的平滑和不间断包络,同时显着提高了衰减因子和离子CCS测量的准确性。与线宽校正方法和线形拟合方法相比,该方法具有更好的抗噪声和分辨率能力,可作为离子CCS测量技术的宝贵辅助手段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Collision Cross Section Measurements in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) Based on the Flipping-Filtering Method

The ion collision cross section (CCS) is closely related to the structural and physical conformation of compounds, making it an ideal parameter for constructing databases. In recent years, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) has gained widespread application in CCS measurements thanks to its ultra-high mass resolution and accuracy. Due to the collisions between ions and neutral molecules within the FT-ICR MS cell, the image current decays. Based on this feature, the ion CCS can be precisely calculated by applying corresponding collision models and algorithms. A new time-frequency analysis method is introduced: the flipping-filtering method based on the Levenberg–Marquardt algorithm. Before filtering, the data undergoes flipping and extension, effectively mitigating the issue of signal point waste commonly associated with traditional filtering techniques. This approach ensures a smooth and uninterrupted envelope of the image current signal while significantly enhancing the accuracy of decay factor and ion CCS measurements. Compared to the linewidth correction method and the line shape fitting method, this method exhibits superior noise resistance and resolution capabilities, serving as a valuable adjunct to ion CCS measurement techniques.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Mass Spectrometry
Journal of Mass Spectrometry 化学-光谱学
CiteScore
5.10
自引率
0.00%
发文量
84
审稿时长
1.5 months
期刊介绍: The Journal of Mass Spectrometry publishes papers on a broad range of topics of interest to scientists working in both fundamental and applied areas involving the study of gaseous ions. The aim of JMS is to serve the scientific community with information provided and arranged to help senior investigators to better stay abreast of new discoveries and studies in their own field, to make them aware of events and developments in associated fields, and to provide students and newcomers the basic tools with which to learn fundamental and applied aspects of mass spectrometry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信