jns软物质和生物物理用KWS-2高强度/大q量程SANS衍射仪的升级:原位SEC、可控原位RH/T变化和广域网检测。

IF 6.1 3区 材料科学 Q1 Biochemistry, Genetics and Molecular Biology
Journal of Applied Crystallography Pub Date : 2025-03-19 eCollection Date: 2025-04-01 DOI:10.1107/S160057672500158X
Jia-Jhen Kang, Ralf Biehl, Georg Brandl, Helmut Korb, Kimio Yoshimura, Vladimir Ossovyi, Andreas Nebel, Jacqueline Lippertz, Ralf Engels, Günter Kemmerling, Alexander Zaft, Hiroki Iwase, Hiroshi Arima-Osonoi, Shin-Ichi Takata, Alexander Weber, Simon Staringer, Baohu Wu, Yue Zhao, Stefan Mattauch, Aurel Radulescu
{"title":"jns软物质和生物物理用KWS-2高强度/大q量程SANS衍射仪的升级:原位SEC、可控原位RH/T变化和广域网检测。","authors":"Jia-Jhen Kang, Ralf Biehl, Georg Brandl, Helmut Korb, Kimio Yoshimura, Vladimir Ossovyi, Andreas Nebel, Jacqueline Lippertz, Ralf Engels, Günter Kemmerling, Alexander Zaft, Hiroki Iwase, Hiroshi Arima-Osonoi, Shin-Ichi Takata, Alexander Weber, Simon Staringer, Baohu Wu, Yue Zhao, Stefan Mattauch, Aurel Radulescu","doi":"10.1107/S160057672500158X","DOIUrl":null,"url":null,"abstract":"<p><p>The KWS-2 small-angle neutron scattering (SANS) diffractometer operated by Jülich Centre for Neutron Science (JCNS) at Heinz Maier-Leibnitz Zentrum, Garching, Germany, is dedicated to the investigation of mesoscopic multi-scale structures and structural changes due to rapid kinetic processes in soft condensed matter and biophysical systems. Following requests from the user community, it has been repeatedly upgraded with respect to the most important methodological parameters of an instrument of this type, namely the intensity on the sample, the instrumental resolution and the minimum scattering variable <i>Q</i> <sub>min</sub>. Here we report on further specific improvements to the sample environment and detection capabilities which have just been completed or are being implemented. Complementary size-exclusion chromatography (SEC) for <i>in situ</i> protein purification was developed and optimized at KWS-2 to provide the instrument with biological samples of controlled quality. The instrument is also currently being equipped with a wide-angle neutron scattering (WANS) detector which will allow it to bridge the atomic and mesoscale, benefiting from the instrument's adjustable resolution down to Δλ/λ = 2%. For controlled relative humidity and temperature (RH/T) on ionic conductive samples for energy applications or biomembranes for biophysical and health applications, a precise dew point generator has recently been characterized and commissioned; this offers great versatility with regard to varying the contrast <i>in situ</i> in the beam on hydrated samples.</p>","PeriodicalId":14950,"journal":{"name":"Journal of Applied Crystallography","volume":"58 Pt 2","pages":"581-594"},"PeriodicalIF":6.1000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11957400/pdf/","citationCount":"0","resultStr":"{\"title\":\"Upgrade of the KWS-2 high-intensity/extended-<i>Q</i>-range SANS diffractometer of JCNS for soft matter and biophysics: <i>in situ</i> SEC, controlled <i>in situ</i> RH/T variation and WANS detection.\",\"authors\":\"Jia-Jhen Kang, Ralf Biehl, Georg Brandl, Helmut Korb, Kimio Yoshimura, Vladimir Ossovyi, Andreas Nebel, Jacqueline Lippertz, Ralf Engels, Günter Kemmerling, Alexander Zaft, Hiroki Iwase, Hiroshi Arima-Osonoi, Shin-Ichi Takata, Alexander Weber, Simon Staringer, Baohu Wu, Yue Zhao, Stefan Mattauch, Aurel Radulescu\",\"doi\":\"10.1107/S160057672500158X\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The KWS-2 small-angle neutron scattering (SANS) diffractometer operated by Jülich Centre for Neutron Science (JCNS) at Heinz Maier-Leibnitz Zentrum, Garching, Germany, is dedicated to the investigation of mesoscopic multi-scale structures and structural changes due to rapid kinetic processes in soft condensed matter and biophysical systems. Following requests from the user community, it has been repeatedly upgraded with respect to the most important methodological parameters of an instrument of this type, namely the intensity on the sample, the instrumental resolution and the minimum scattering variable <i>Q</i> <sub>min</sub>. Here we report on further specific improvements to the sample environment and detection capabilities which have just been completed or are being implemented. Complementary size-exclusion chromatography (SEC) for <i>in situ</i> protein purification was developed and optimized at KWS-2 to provide the instrument with biological samples of controlled quality. The instrument is also currently being equipped with a wide-angle neutron scattering (WANS) detector which will allow it to bridge the atomic and mesoscale, benefiting from the instrument's adjustable resolution down to Δλ/λ = 2%. For controlled relative humidity and temperature (RH/T) on ionic conductive samples for energy applications or biomembranes for biophysical and health applications, a precise dew point generator has recently been characterized and commissioned; this offers great versatility with regard to varying the contrast <i>in situ</i> in the beam on hydrated samples.</p>\",\"PeriodicalId\":14950,\"journal\":{\"name\":\"Journal of Applied Crystallography\",\"volume\":\"58 Pt 2\",\"pages\":\"581-594\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2025-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11957400/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Crystallography\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1107/S160057672500158X\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/4/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Crystallography","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1107/S160057672500158X","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

摘要

KWS-2型小角中子散射(SANS)衍射仪由位于德国加兴Heinz Maier-Leibnitz中心的j利希中子科学中心(JCNS)运行,用于研究软凝聚态物质和生物物理系统中由于快速动力学过程而引起的介观多尺度结构和结构变化。根据用户群体的要求,它已经在这类仪器最重要的方法学参数方面进行了多次升级,即样品上的强度,仪器分辨率和最小散射变量Q min。在这里,我们报告了刚刚完成或正在实施的样品环境和检测能力的进一步具体改进。在KWS-2上开发并优化了用于原位蛋白纯化的互补尺寸排除色谱(SEC),为仪器提供质量可控的生物样品。该仪器目前还配备了一个广角中子散射(wan)探测器,这将使它能够桥接原子和中尺度,受益于仪器的可调分辨率至Δλ/λ = 2%。为了控制离子导电样品的相对湿度和温度(RH/T),用于能源应用或生物物理和健康应用的生物膜,一种精确的露点发生器最近被表征并投入使用;这提供了很大的通用性,关于在水合样品上改变光束的原位对比度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Upgrade of the KWS-2 high-intensity/extended-Q-range SANS diffractometer of JCNS for soft matter and biophysics: in situ SEC, controlled in situ RH/T variation and WANS detection.

The KWS-2 small-angle neutron scattering (SANS) diffractometer operated by Jülich Centre for Neutron Science (JCNS) at Heinz Maier-Leibnitz Zentrum, Garching, Germany, is dedicated to the investigation of mesoscopic multi-scale structures and structural changes due to rapid kinetic processes in soft condensed matter and biophysical systems. Following requests from the user community, it has been repeatedly upgraded with respect to the most important methodological parameters of an instrument of this type, namely the intensity on the sample, the instrumental resolution and the minimum scattering variable Q min. Here we report on further specific improvements to the sample environment and detection capabilities which have just been completed or are being implemented. Complementary size-exclusion chromatography (SEC) for in situ protein purification was developed and optimized at KWS-2 to provide the instrument with biological samples of controlled quality. The instrument is also currently being equipped with a wide-angle neutron scattering (WANS) detector which will allow it to bridge the atomic and mesoscale, benefiting from the instrument's adjustable resolution down to Δλ/λ = 2%. For controlled relative humidity and temperature (RH/T) on ionic conductive samples for energy applications or biomembranes for biophysical and health applications, a precise dew point generator has recently been characterized and commissioned; this offers great versatility with regard to varying the contrast in situ in the beam on hydrated samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.00
自引率
3.30%
发文量
178
审稿时长
4.7 months
期刊介绍: Many research topics in condensed matter research, materials science and the life sciences make use of crystallographic methods to study crystalline and non-crystalline matter with neutrons, X-rays and electrons. Articles published in the Journal of Applied Crystallography focus on these methods and their use in identifying structural and diffusion-controlled phase transformations, structure-property relationships, structural changes of defects, interfaces and surfaces, etc. Developments of instrumentation and crystallographic apparatus, theory and interpretation, numerical analysis and other related subjects are also covered. The journal is the primary place where crystallographic computer program information is published.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信