Yong-Han Peng, Jing-Wen Tang, Yi-Hua Li, Fei-Fang Zhang, Bing-Cheng Yang
{"title":"[用于去除离子色谱系统洗脱液中二氧化碳的气液分离器的设计与应用]。","authors":"Yong-Han Peng, Jing-Wen Tang, Yi-Hua Li, Fei-Fang Zhang, Bing-Cheng Yang","doi":"10.3724/SP.J.1123.2024.03021","DOIUrl":null,"url":null,"abstract":"<p><p>A gas-liquid separator (GLS) for the removal of carbon dioxide in the eluent of an ion chromatography (IC) system was developed. Firstly, the microporous hollow fiber polypropylene tube (PP-T) was inserted into the polytetrafluoroethylene tube (PTFE-T) with suitable inner diameter to form a double casing structure and wound into a spiral shape. Each terminal of the PP-T is 3 cm longer than that of the PTFE-T. Then the terminals of PP-T and PTFE-T were fixed respectively on two horizontal joints equipped with tee joints, and the regenerated liquid pipeline was fixed on a vertical arm interface equipped with tee joints. When the carbonate eluent flows into PP-T from the upstream suppressor, the inhibited carbonate solution will decompose and produce CO<sub>2</sub>, which then escapes through PP-T and enters the flowing absorption solution located in the annular space between PP-T and PTFE-T, so as to achieve continuous and effective CO<sub>2</sub> removal. The production conditions and operating conditions of GLS were optimized, including the length of PP-T, the inner diameter of PTFE-T, the operating temperature, the type, concentration and flow rate of the absorption solution. The experimental results show that when 40 mmol/L potassium hydroxide solution is used as absorption solution, the removal efficiency of CO<sub>2</sub> can reach more than 98% at the flow rate of 1 mL/min. Higher operating temperature is helpful to improve the removal efficiency of CO<sub>2</sub> and reduce the baseline noise. The optimized operating temperature in this study was 40 ℃. When applying this GLS to the IC system for carbonate eluent, using a mixed eluent of 1.8 mmol/L potassium carbonate-3.2 mmol/L potassium bicarbonate (1∶1, v/v), the background conductance signal decreased from 41.6 mV without GLS to 5.5 mV after using GLS. Using a mixed standard solution of common anions (F<sup>-</sup>、Cl<sup>-</sup>、[Formula: see text] on the separation of other anions.</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"43 4","pages":"382-387"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11966376/pdf/","citationCount":"0","resultStr":"{\"title\":\"[Design and application of a gas-liquid separator for the removal of carbon dioxide in the eluent of an ion chromatography system].\",\"authors\":\"Yong-Han Peng, Jing-Wen Tang, Yi-Hua Li, Fei-Fang Zhang, Bing-Cheng Yang\",\"doi\":\"10.3724/SP.J.1123.2024.03021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A gas-liquid separator (GLS) for the removal of carbon dioxide in the eluent of an ion chromatography (IC) system was developed. Firstly, the microporous hollow fiber polypropylene tube (PP-T) was inserted into the polytetrafluoroethylene tube (PTFE-T) with suitable inner diameter to form a double casing structure and wound into a spiral shape. Each terminal of the PP-T is 3 cm longer than that of the PTFE-T. Then the terminals of PP-T and PTFE-T were fixed respectively on two horizontal joints equipped with tee joints, and the regenerated liquid pipeline was fixed on a vertical arm interface equipped with tee joints. When the carbonate eluent flows into PP-T from the upstream suppressor, the inhibited carbonate solution will decompose and produce CO<sub>2</sub>, which then escapes through PP-T and enters the flowing absorption solution located in the annular space between PP-T and PTFE-T, so as to achieve continuous and effective CO<sub>2</sub> removal. The production conditions and operating conditions of GLS were optimized, including the length of PP-T, the inner diameter of PTFE-T, the operating temperature, the type, concentration and flow rate of the absorption solution. The experimental results show that when 40 mmol/L potassium hydroxide solution is used as absorption solution, the removal efficiency of CO<sub>2</sub> can reach more than 98% at the flow rate of 1 mL/min. Higher operating temperature is helpful to improve the removal efficiency of CO<sub>2</sub> and reduce the baseline noise. The optimized operating temperature in this study was 40 ℃. When applying this GLS to the IC system for carbonate eluent, using a mixed eluent of 1.8 mmol/L potassium carbonate-3.2 mmol/L potassium bicarbonate (1∶1, v/v), the background conductance signal decreased from 41.6 mV without GLS to 5.5 mV after using GLS. Using a mixed standard solution of common anions (F<sup>-</sup>、Cl<sup>-</sup>、[Formula: see text] on the separation of other anions.</p>\",\"PeriodicalId\":101336,\"journal\":{\"name\":\"Se pu = Chinese journal of chromatography\",\"volume\":\"43 4\",\"pages\":\"382-387\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11966376/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Se pu = Chinese journal of chromatography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3724/SP.J.1123.2024.03021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2024.03021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Design and application of a gas-liquid separator for the removal of carbon dioxide in the eluent of an ion chromatography system].
A gas-liquid separator (GLS) for the removal of carbon dioxide in the eluent of an ion chromatography (IC) system was developed. Firstly, the microporous hollow fiber polypropylene tube (PP-T) was inserted into the polytetrafluoroethylene tube (PTFE-T) with suitable inner diameter to form a double casing structure and wound into a spiral shape. Each terminal of the PP-T is 3 cm longer than that of the PTFE-T. Then the terminals of PP-T and PTFE-T were fixed respectively on two horizontal joints equipped with tee joints, and the regenerated liquid pipeline was fixed on a vertical arm interface equipped with tee joints. When the carbonate eluent flows into PP-T from the upstream suppressor, the inhibited carbonate solution will decompose and produce CO2, which then escapes through PP-T and enters the flowing absorption solution located in the annular space between PP-T and PTFE-T, so as to achieve continuous and effective CO2 removal. The production conditions and operating conditions of GLS were optimized, including the length of PP-T, the inner diameter of PTFE-T, the operating temperature, the type, concentration and flow rate of the absorption solution. The experimental results show that when 40 mmol/L potassium hydroxide solution is used as absorption solution, the removal efficiency of CO2 can reach more than 98% at the flow rate of 1 mL/min. Higher operating temperature is helpful to improve the removal efficiency of CO2 and reduce the baseline noise. The optimized operating temperature in this study was 40 ℃. When applying this GLS to the IC system for carbonate eluent, using a mixed eluent of 1.8 mmol/L potassium carbonate-3.2 mmol/L potassium bicarbonate (1∶1, v/v), the background conductance signal decreased from 41.6 mV without GLS to 5.5 mV after using GLS. Using a mixed standard solution of common anions (F-、Cl-、[Formula: see text] on the separation of other anions.