Lawrence M Wei, Daniel Pereda, Danny Ramzy, Feras H Khaliel, Ghulam Murtaza, James Hunter Mehaffey, Nai-Hsin Chi, Robinson Poffo, Štěpán Černý, Jan Vojáček, Tristan D Yan, Serguei Melnitchouk, Alberto C Weber, Robert L Smith, Goya V Raikar, Ali Darehzereshki, Arnar Geirsson, Arman Arghami, Jose L Navia, Johannes Bonatti, Vinay Badhwar
{"title":"国际多中心机器人主动脉瓣置换术经验的纵向结果。","authors":"Lawrence M Wei, Daniel Pereda, Danny Ramzy, Feras H Khaliel, Ghulam Murtaza, James Hunter Mehaffey, Nai-Hsin Chi, Robinson Poffo, Štěpán Černý, Jan Vojáček, Tristan D Yan, Serguei Melnitchouk, Alberto C Weber, Robert L Smith, Goya V Raikar, Ali Darehzereshki, Arnar Geirsson, Arman Arghami, Jose L Navia, Johannes Bonatti, Vinay Badhwar","doi":"10.1093/ejcts/ezaf103","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>In an effort to maintain the technical aspects of traditional prosthetic surgical aortic valve replacement (AVR) while reducing invasiveness and facilitate options for concomitant operations, transaxillary lateral mini-thoracotomy endoscopic robotic-assisted aortic valve replacement (RAVR) has been introduced. The present data highlight the contemporary international collaborative experience.</p><p><strong>Methods: </strong>All consecutive patients undergoing standardized RAVR across 10 international sites (1/2020-7/2024) were evaluated using a central database with 1 year follow-up.</p><p><strong>Results: </strong>A total of 300 patients were analysed with a median predicted risk of 1.6% with aortic stenosis in 85.7%, nearly half with bicuspid valves. Biological prostheses were implanted in 220 (73.3%) with a median valve size 23 mm, 10% receiving aortic root enlargement, with 17% of all patients undergoing concomitant procedures. Median cross-clamp 120 min with no conversions to sternotomy. Median length of stay was 5 days, 4.3% with prolonged ventilation, 1.7% renal failure, 1.0% stroke and 8.3% required re-thoracotomy for evacuation of haemothorax. There were two 30-day operative mortalities (0.7%). The new permanent pacemaker rate for the full cohort was 2.6%. Of 163 patients with complete 1-year clinical and echocardiographic follow-up, mean aortic valve gradient was 10 mmHg and all but 2 patients (1.2%) had trace to no prosthetic or paravalvular insufficiency.</p><p><strong>Conclusions: </strong>RAVR is safe and effective, providing the reproducible benefits of surgical AVR while affording a less invasive approach that permits the opportunity for concomitant procedures. For low and intermediate risk patients with aortic valve disease, RAVR is a potential reproducible alternative for patients and heart teams.</p>","PeriodicalId":11938,"journal":{"name":"European Journal of Cardio-Thoracic Surgery","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Longitudinal outcomes following international multicentre experience with robotic aortic valve replacement†.\",\"authors\":\"Lawrence M Wei, Daniel Pereda, Danny Ramzy, Feras H Khaliel, Ghulam Murtaza, James Hunter Mehaffey, Nai-Hsin Chi, Robinson Poffo, Štěpán Černý, Jan Vojáček, Tristan D Yan, Serguei Melnitchouk, Alberto C Weber, Robert L Smith, Goya V Raikar, Ali Darehzereshki, Arnar Geirsson, Arman Arghami, Jose L Navia, Johannes Bonatti, Vinay Badhwar\",\"doi\":\"10.1093/ejcts/ezaf103\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>In an effort to maintain the technical aspects of traditional prosthetic surgical aortic valve replacement (AVR) while reducing invasiveness and facilitate options for concomitant operations, transaxillary lateral mini-thoracotomy endoscopic robotic-assisted aortic valve replacement (RAVR) has been introduced. The present data highlight the contemporary international collaborative experience.</p><p><strong>Methods: </strong>All consecutive patients undergoing standardized RAVR across 10 international sites (1/2020-7/2024) were evaluated using a central database with 1 year follow-up.</p><p><strong>Results: </strong>A total of 300 patients were analysed with a median predicted risk of 1.6% with aortic stenosis in 85.7%, nearly half with bicuspid valves. Biological prostheses were implanted in 220 (73.3%) with a median valve size 23 mm, 10% receiving aortic root enlargement, with 17% of all patients undergoing concomitant procedures. Median cross-clamp 120 min with no conversions to sternotomy. Median length of stay was 5 days, 4.3% with prolonged ventilation, 1.7% renal failure, 1.0% stroke and 8.3% required re-thoracotomy for evacuation of haemothorax. There were two 30-day operative mortalities (0.7%). The new permanent pacemaker rate for the full cohort was 2.6%. Of 163 patients with complete 1-year clinical and echocardiographic follow-up, mean aortic valve gradient was 10 mmHg and all but 2 patients (1.2%) had trace to no prosthetic or paravalvular insufficiency.</p><p><strong>Conclusions: </strong>RAVR is safe and effective, providing the reproducible benefits of surgical AVR while affording a less invasive approach that permits the opportunity for concomitant procedures. For low and intermediate risk patients with aortic valve disease, RAVR is a potential reproducible alternative for patients and heart teams.</p>\",\"PeriodicalId\":11938,\"journal\":{\"name\":\"European Journal of Cardio-Thoracic Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Cardio-Thoracic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ejcts/ezaf103\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Cardio-Thoracic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ejcts/ezaf103","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Longitudinal outcomes following international multicentre experience with robotic aortic valve replacement†.
Objectives: In an effort to maintain the technical aspects of traditional prosthetic surgical aortic valve replacement (AVR) while reducing invasiveness and facilitate options for concomitant operations, transaxillary lateral mini-thoracotomy endoscopic robotic-assisted aortic valve replacement (RAVR) has been introduced. The present data highlight the contemporary international collaborative experience.
Methods: All consecutive patients undergoing standardized RAVR across 10 international sites (1/2020-7/2024) were evaluated using a central database with 1 year follow-up.
Results: A total of 300 patients were analysed with a median predicted risk of 1.6% with aortic stenosis in 85.7%, nearly half with bicuspid valves. Biological prostheses were implanted in 220 (73.3%) with a median valve size 23 mm, 10% receiving aortic root enlargement, with 17% of all patients undergoing concomitant procedures. Median cross-clamp 120 min with no conversions to sternotomy. Median length of stay was 5 days, 4.3% with prolonged ventilation, 1.7% renal failure, 1.0% stroke and 8.3% required re-thoracotomy for evacuation of haemothorax. There were two 30-day operative mortalities (0.7%). The new permanent pacemaker rate for the full cohort was 2.6%. Of 163 patients with complete 1-year clinical and echocardiographic follow-up, mean aortic valve gradient was 10 mmHg and all but 2 patients (1.2%) had trace to no prosthetic or paravalvular insufficiency.
Conclusions: RAVR is safe and effective, providing the reproducible benefits of surgical AVR while affording a less invasive approach that permits the opportunity for concomitant procedures. For low and intermediate risk patients with aortic valve disease, RAVR is a potential reproducible alternative for patients and heart teams.
期刊介绍:
The primary aim of the European Journal of Cardio-Thoracic Surgery is to provide a medium for the publication of high-quality original scientific reports documenting progress in cardiac and thoracic surgery. The journal publishes reports of significant clinical and experimental advances related to surgery of the heart, the great vessels and the chest. The European Journal of Cardio-Thoracic Surgery is an international journal and accepts submissions from all regions. The journal is supported by a number of leading European societies.