选择可穿戴设备来测量社区居住成年人的心血管功能:设备选择实用指南的应用

Jessica K. Lu MEng , Weilan Wang PhD , Jorming Goh PhD , Andrea B. Maier MD, PhD
{"title":"选择可穿戴设备来测量社区居住成年人的心血管功能:设备选择实用指南的应用","authors":"Jessica K. Lu MEng ,&nbsp;Weilan Wang PhD ,&nbsp;Jorming Goh PhD ,&nbsp;Andrea B. Maier MD, PhD","doi":"10.1016/j.mcpdig.2025.100202","DOIUrl":null,"url":null,"abstract":"<div><div>Continuous monitoring of cardiovascular functions can provide crucial insights into the health status and lifestyle behaviors of an individual. Wearable devices offer a convenient and cost-effective solution for collecting cardiovascular measurements outside clinical settings. However, the abundance of available devices poses challenges for researchers, health care professionals, and device users in selecting the most suitable one. This article illustrates the application of a practical guide for selecting wearable devices for the continuous monitoring of cardiovascular functions in community-dwelling adults who are generally healthy or have minimal, well-managed chronic conditions. An initial systematic review of the literature revealed 216 devices, each of which were assessed on the basis of 5 core criteria from the guide: (1) continuous monitoring capability, (2) device availability and suitability, (3) technical performance (accuracy and precision), (4) feasibility of use, and (5) cost evaluation. From the 216 devices, there were 136 devices capable of continuous monitoring. After the exclusion of unavailable and unsuitable devices, 53 devices underwent validation assessment of accuracy and precision. Although COSMIN criteria were applied to evaluate technical performance, a lack of validation for certain devices limits a comprehensive evaluation. After selection of valid devices, the feasibility and cost of 20 devices were examined. Wearable devices, such as the Apple Watch Series 9, Fitbit Charge 6, Garmin vívosmart 5, and Oura Ring Gen3, emerged as suitable devices to measure cardiovascular function in community-dwelling adults. The systematic process for device selection could also be applied to select wearable devices for the measurement of other physiologic variables and lifestyle behaviors.</div></div>","PeriodicalId":74127,"journal":{"name":"Mayo Clinic Proceedings. Digital health","volume":"3 2","pages":"Article 100202"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Selecting Wearable Devices to Measure Cardiovascular Functions in Community-Dwelling Adults: Application of a Practical Guide for Device Selection\",\"authors\":\"Jessica K. Lu MEng ,&nbsp;Weilan Wang PhD ,&nbsp;Jorming Goh PhD ,&nbsp;Andrea B. Maier MD, PhD\",\"doi\":\"10.1016/j.mcpdig.2025.100202\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Continuous monitoring of cardiovascular functions can provide crucial insights into the health status and lifestyle behaviors of an individual. Wearable devices offer a convenient and cost-effective solution for collecting cardiovascular measurements outside clinical settings. However, the abundance of available devices poses challenges for researchers, health care professionals, and device users in selecting the most suitable one. This article illustrates the application of a practical guide for selecting wearable devices for the continuous monitoring of cardiovascular functions in community-dwelling adults who are generally healthy or have minimal, well-managed chronic conditions. An initial systematic review of the literature revealed 216 devices, each of which were assessed on the basis of 5 core criteria from the guide: (1) continuous monitoring capability, (2) device availability and suitability, (3) technical performance (accuracy and precision), (4) feasibility of use, and (5) cost evaluation. From the 216 devices, there were 136 devices capable of continuous monitoring. After the exclusion of unavailable and unsuitable devices, 53 devices underwent validation assessment of accuracy and precision. Although COSMIN criteria were applied to evaluate technical performance, a lack of validation for certain devices limits a comprehensive evaluation. After selection of valid devices, the feasibility and cost of 20 devices were examined. Wearable devices, such as the Apple Watch Series 9, Fitbit Charge 6, Garmin vívosmart 5, and Oura Ring Gen3, emerged as suitable devices to measure cardiovascular function in community-dwelling adults. The systematic process for device selection could also be applied to select wearable devices for the measurement of other physiologic variables and lifestyle behaviors.</div></div>\",\"PeriodicalId\":74127,\"journal\":{\"name\":\"Mayo Clinic Proceedings. Digital health\",\"volume\":\"3 2\",\"pages\":\"Article 100202\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mayo Clinic Proceedings. Digital health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2949761225000094\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mayo Clinic Proceedings. Digital health","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949761225000094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

持续监测心血管功能可以对个人的健康状况和生活方式行为提供重要的见解。可穿戴设备为在临床环境之外收集心血管测量数据提供了一种方便且经济高效的解决方案。然而,大量的可用设备给研究人员、卫生保健专业人员和设备用户在选择最合适的设备方面带来了挑战。本文阐述了一种实用指南的应用,用于选择可穿戴设备,用于持续监测社区居住成年人的心血管功能,这些成年人通常健康或有最小的、管理良好的慢性病。对文献的初步系统回顾显示了216个设备,每个设备都是根据指南中的5个核心标准进行评估的:(1)持续监测能力,(2)设备可用性和适用性,(3)技术性能(准确性和精密度),(4)使用可行性,(5)成本评估。在216个装置中,有136个装置能够持续监测。在排除不可用和不合适的器械后,53个器械进行了准确性和精密度的验证评估。虽然采用了COSMIN标准来评价技术性能,但缺乏对某些设备的验证限制了全面评价。在选择了有效装置后,对20种装置的可行性和成本进行了考察。可穿戴设备,如Apple Watch Series 9、Fitbit Charge 6、Garmin vívosmart 5和Oura Ring Gen3,成为测量社区居民心血管功能的合适设备。设备选择的系统过程也可以应用于选择可穿戴设备来测量其他生理变量和生活方式行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Selecting Wearable Devices to Measure Cardiovascular Functions in Community-Dwelling Adults: Application of a Practical Guide for Device Selection
Continuous monitoring of cardiovascular functions can provide crucial insights into the health status and lifestyle behaviors of an individual. Wearable devices offer a convenient and cost-effective solution for collecting cardiovascular measurements outside clinical settings. However, the abundance of available devices poses challenges for researchers, health care professionals, and device users in selecting the most suitable one. This article illustrates the application of a practical guide for selecting wearable devices for the continuous monitoring of cardiovascular functions in community-dwelling adults who are generally healthy or have minimal, well-managed chronic conditions. An initial systematic review of the literature revealed 216 devices, each of which were assessed on the basis of 5 core criteria from the guide: (1) continuous monitoring capability, (2) device availability and suitability, (3) technical performance (accuracy and precision), (4) feasibility of use, and (5) cost evaluation. From the 216 devices, there were 136 devices capable of continuous monitoring. After the exclusion of unavailable and unsuitable devices, 53 devices underwent validation assessment of accuracy and precision. Although COSMIN criteria were applied to evaluate technical performance, a lack of validation for certain devices limits a comprehensive evaluation. After selection of valid devices, the feasibility and cost of 20 devices were examined. Wearable devices, such as the Apple Watch Series 9, Fitbit Charge 6, Garmin vívosmart 5, and Oura Ring Gen3, emerged as suitable devices to measure cardiovascular function in community-dwelling adults. The systematic process for device selection could also be applied to select wearable devices for the measurement of other physiologic variables and lifestyle behaviors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Mayo Clinic Proceedings. Digital health
Mayo Clinic Proceedings. Digital health Medicine and Dentistry (General), Health Informatics, Public Health and Health Policy
自引率
0.00%
发文量
0
审稿时长
47 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信