冷冻象鼻:混合假体的概述。

Expert review of medical devices Pub Date : 2025-03-01 Epub Date: 2025-03-24 DOI:10.1080/17434440.2025.2471455
Mariam Hussain, Yousif F Jubouri, Aya Hammad, Ihsan Abubacker, Marco Franchin, Francesca Mauri, Gabriele Piffaretti, Idhrees Mohammed, Matti Jubouri, Mohamad Bashir
{"title":"冷冻象鼻:混合假体的概述。","authors":"Mariam Hussain, Yousif F Jubouri, Aya Hammad, Ihsan Abubacker, Marco Franchin, Francesca Mauri, Gabriele Piffaretti, Idhrees Mohammed, Matti Jubouri, Mohamad Bashir","doi":"10.1080/17434440.2025.2471455","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Thoracic aortic pathologies implicating the aortic arch and the descending thoracic aorta (DTA) are primarily managed with total aortic arch replacement (TAR). This can be performed as a single-procedure hybrid fashion using the frozen elephant trunk technique (FET), which utilizes hybrid prosthesis. Nevertheless, FET presents certain challenges such as distal stent graft-induced new entry (dSINE), negative aortic remodeling, and reintervention.</p><p><strong>Areas covered: </strong>The narrative review provides an overview of the four majors FET prosthesis, highlighting their design features, mechanical properties, configurations, and variants, and evaluating their clinical outcomes reported in the literature. The leading prosthesises were compared through their mortality and survival rates, neurological outcomes, dSINE, aortic remodeling, and reintervention rates.</p><p><strong>Expert opinion: </strong>Four FET devices can be considered the main option on the global market; Thoraflex, E-Vita, Cronus, and Frozenix J Graft. Each hybrid prosthesis (HP) features unique design characteristics, resulting in varying clinical outcomes. Thoraflex and E-Vita are the most widely used and investigated HPs, whilst the use of Cronus and Frozenix is geographically confined to mainly manufacturers' countries. The rates of early mortality, stroke, SCI, dSINE, and reintervention rates were found to be comparable among the four devices, yet, Thoraflex seemed to offer the most optimal clinical profile.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":" ","pages":"193-208"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The frozen elephant trunk: an overview of hybrid prostheses.\",\"authors\":\"Mariam Hussain, Yousif F Jubouri, Aya Hammad, Ihsan Abubacker, Marco Franchin, Francesca Mauri, Gabriele Piffaretti, Idhrees Mohammed, Matti Jubouri, Mohamad Bashir\",\"doi\":\"10.1080/17434440.2025.2471455\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Thoracic aortic pathologies implicating the aortic arch and the descending thoracic aorta (DTA) are primarily managed with total aortic arch replacement (TAR). This can be performed as a single-procedure hybrid fashion using the frozen elephant trunk technique (FET), which utilizes hybrid prosthesis. Nevertheless, FET presents certain challenges such as distal stent graft-induced new entry (dSINE), negative aortic remodeling, and reintervention.</p><p><strong>Areas covered: </strong>The narrative review provides an overview of the four majors FET prosthesis, highlighting their design features, mechanical properties, configurations, and variants, and evaluating their clinical outcomes reported in the literature. The leading prosthesises were compared through their mortality and survival rates, neurological outcomes, dSINE, aortic remodeling, and reintervention rates.</p><p><strong>Expert opinion: </strong>Four FET devices can be considered the main option on the global market; Thoraflex, E-Vita, Cronus, and Frozenix J Graft. Each hybrid prosthesis (HP) features unique design characteristics, resulting in varying clinical outcomes. Thoraflex and E-Vita are the most widely used and investigated HPs, whilst the use of Cronus and Frozenix is geographically confined to mainly manufacturers' countries. The rates of early mortality, stroke, SCI, dSINE, and reintervention rates were found to be comparable among the four devices, yet, Thoraflex seemed to offer the most optimal clinical profile.</p>\",\"PeriodicalId\":94006,\"journal\":{\"name\":\"Expert review of medical devices\",\"volume\":\" \",\"pages\":\"193-208\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert review of medical devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/17434440.2025.2471455\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2025.2471455","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

胸主动脉病变累及主动脉弓和胸降主动脉(DTA)主要通过全主动脉弓置换术(TAR)进行治疗。这可以使用冷冻象鼻技术(FET)作为单程序混合方式进行,该技术利用混合假体。然而,FET存在一定的挑战,如远端支架移植诱导的新进入(dsin),负主动脉重构,再介入。涵盖领域:叙述性综述概述了四种主要的FET假体,强调了它们的设计特征、机械性能、结构和变体,并评估了文献中报道的它们的临床结果。比较两组假体的死亡率和生存率、神经学预后、dsin、主动脉重塑和再干预率。专家意见:四场效应管器件可以被认为是全球市场的主要选择;Thoraflex, E-Vita, Cronus和Frozenix J Graft。每种混合假体(HP)具有独特的设计特征,导致不同的临床结果。Thoraflex和E-Vita是最广泛使用和研究的hp,而Cronus和Frozenix的使用在地理上仅限于主要制造商的国家。四种装置的早期死亡率、卒中、SCI、dsin和再干预率是相似的,然而,Thoraflex似乎提供了最理想的临床表现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The frozen elephant trunk: an overview of hybrid prostheses.

Introduction: Thoracic aortic pathologies implicating the aortic arch and the descending thoracic aorta (DTA) are primarily managed with total aortic arch replacement (TAR). This can be performed as a single-procedure hybrid fashion using the frozen elephant trunk technique (FET), which utilizes hybrid prosthesis. Nevertheless, FET presents certain challenges such as distal stent graft-induced new entry (dSINE), negative aortic remodeling, and reintervention.

Areas covered: The narrative review provides an overview of the four majors FET prosthesis, highlighting their design features, mechanical properties, configurations, and variants, and evaluating their clinical outcomes reported in the literature. The leading prosthesises were compared through their mortality and survival rates, neurological outcomes, dSINE, aortic remodeling, and reintervention rates.

Expert opinion: Four FET devices can be considered the main option on the global market; Thoraflex, E-Vita, Cronus, and Frozenix J Graft. Each hybrid prosthesis (HP) features unique design characteristics, resulting in varying clinical outcomes. Thoraflex and E-Vita are the most widely used and investigated HPs, whilst the use of Cronus and Frozenix is geographically confined to mainly manufacturers' countries. The rates of early mortality, stroke, SCI, dSINE, and reintervention rates were found to be comparable among the four devices, yet, Thoraflex seemed to offer the most optimal clinical profile.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信