{"title":"WebCT -开源的基于web的GUI,用于实时x射线模拟","authors":"Iwan T. Mitchell ,&nbsp;Jean Michel Létang ,&nbsp;Llion Marc Evans ,&nbsp;Franck P. Vidal","doi":"10.1016/j.tmater.2025.100057","DOIUrl":null,"url":null,"abstract":"<div><div>Scan planning for X-ray CT systems can be difficult due to the large number of elements affecting scan quality. The use of X-ray simulation can answer feasibility questions, however existing methods are focused on experts who are familiar with XCT and programming knowledge. WebCT is a user-centric application for performing virtual XCT scans with the validated X-ray simulator gVirtualXray. Focused on accessibility, the interface allows changing all scanning parameters; from tube characteristics to detector energy response, while allowing full-scale simulation and reconstruction in minutes. WebCT is available as a free, open-source application, giving full control over a virtual lab-CT or synchrotron system. Configurations can be saved, shared, or even imported from many popular XCT dataset formats. We demonstrate in this paper the use of WebCT as a scan planning tool, using a simple CAD mockup to select filtration based on transmission before scanning.</div></div>","PeriodicalId":101254,"journal":{"name":"Tomography of Materials and Structures","volume":"8 ","pages":"Article 100057"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"WebCT – OpenSource web-based GUI for real-time X-ray simulation\",\"authors\":\"Iwan T. Mitchell ,&nbsp;Jean Michel Létang ,&nbsp;Llion Marc Evans ,&nbsp;Franck P. Vidal\",\"doi\":\"10.1016/j.tmater.2025.100057\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Scan planning for X-ray CT systems can be difficult due to the large number of elements affecting scan quality. The use of X-ray simulation can answer feasibility questions, however existing methods are focused on experts who are familiar with XCT and programming knowledge. WebCT is a user-centric application for performing virtual XCT scans with the validated X-ray simulator gVirtualXray. Focused on accessibility, the interface allows changing all scanning parameters; from tube characteristics to detector energy response, while allowing full-scale simulation and reconstruction in minutes. WebCT is available as a free, open-source application, giving full control over a virtual lab-CT or synchrotron system. Configurations can be saved, shared, or even imported from many popular XCT dataset formats. We demonstrate in this paper the use of WebCT as a scan planning tool, using a simple CAD mockup to select filtration based on transmission before scanning.</div></div>\",\"PeriodicalId\":101254,\"journal\":{\"name\":\"Tomography of Materials and Structures\",\"volume\":\"8 \",\"pages\":\"Article 100057\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tomography of Materials and Structures\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2949673X25000105\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tomography of Materials and Structures","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949673X25000105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于影响扫描质量的因素很多,x射线CT系统的扫描计划可能很困难。使用x射线模拟可以回答可行性问题,但是现有的方法主要集中在熟悉XCT和编程知识的专家身上。WebCT是一个以用户为中心的应用程序,用于使用经过验证的x射线模拟器gVirtualXray执行虚拟XCT扫描。专注于可访问性,界面允许更改所有扫描参数;从管道特性到探测器能量响应,同时允许在几分钟内进行全尺寸模拟和重建。WebCT是一个免费的开源应用程序,可以完全控制虚拟实验室- ct或同步加速器系统。可以保存、共享配置,甚至可以从许多流行的XCT数据集格式导入配置。在本文中,我们演示了使用WebCT作为扫描规划工具,使用一个简单的CAD模型来选择扫描前基于传输的过滤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
WebCT – OpenSource web-based GUI for real-time X-ray simulation
Scan planning for X-ray CT systems can be difficult due to the large number of elements affecting scan quality. The use of X-ray simulation can answer feasibility questions, however existing methods are focused on experts who are familiar with XCT and programming knowledge. WebCT is a user-centric application for performing virtual XCT scans with the validated X-ray simulator gVirtualXray. Focused on accessibility, the interface allows changing all scanning parameters; from tube characteristics to detector energy response, while allowing full-scale simulation and reconstruction in minutes. WebCT is available as a free, open-source application, giving full control over a virtual lab-CT or synchrotron system. Configurations can be saved, shared, or even imported from many popular XCT dataset formats. We demonstrate in this paper the use of WebCT as a scan planning tool, using a simple CAD mockup to select filtration based on transmission before scanning.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信