小儿胸外科肺部超声定位支气管阻滞剂的可行性:回顾性分析。

IF 2.3 3区 医学 Q2 ANESTHESIOLOGY
Weiwei Cai, Yuting Song, Wei Gu, Huanhuan Ni, Huiying Shao, Hongqiang Huang
{"title":"小儿胸外科肺部超声定位支气管阻滞剂的可行性:回顾性分析。","authors":"Weiwei Cai, Yuting Song, Wei Gu, Huanhuan Ni, Huiying Shao, Hongqiang Huang","doi":"10.1186/s12871-025-03006-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To identify the feasibility of using lung ultrasound to determine the position of bronchial blockers in pediatric patients.</p><p><strong>Methods: </strong>In this study, children aged 4-8 years who underwent elective right one-lung ventilation at our hospital between January 2019 and August 2022 were selected. We collected the results of lung ultrasound and fiberoptic bronchoscopy during the placement of bronchial blockers in these children. The accuracy, sensitivity, and specificity of lung ultrasound in determining the position of bronchial blockers were calculated. Additionally, the reproducibility of lung ultrasound in determining the appropriateness of bronchial blockers was also calculated. Furthermore, information regarding whether there were complications associated with lung ultrasound examination or fiberoptic bronchoscopy was also collected.</p><p><strong>Results: </strong>The accuracy of lung ultrasound for determining the position of bronchial blockers was 95.0%. When the position of BBs was appropriate, the sensitivity of lung ultrasound was 96.3% and the specificity was 88.9%. When the position of BBs was too shallow, the sensitivity of lung ultrasound was 75% and the specificity was 96.7%. The reproducibility test of lung ultrasound for determining the position of bronchial blockers had a weighted kappa value of 0.91, P < 0.001. In this study we found 6 children had hypoxemia and 6 children had airway mucosal bleeding during fiberoptic bronchoscopy. And no complications linked to lung ultrasound examination were observed.</p><p><strong>Conclusion: </strong>Lung ultrasound has high accuracy, sensitivity, specificity, and repeatability in determining the position of bronchial blockers. It is a new and safe method to determine the position of bronchial blockers.</p>","PeriodicalId":9190,"journal":{"name":"BMC Anesthesiology","volume":"25 1","pages":"137"},"PeriodicalIF":2.3000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11927112/pdf/","citationCount":"0","resultStr":"{\"title\":\"Feasibility of lung ultrasound for locating bronchial blockers in pediatric thoracic surgery: a retrospective analysis.\",\"authors\":\"Weiwei Cai, Yuting Song, Wei Gu, Huanhuan Ni, Huiying Shao, Hongqiang Huang\",\"doi\":\"10.1186/s12871-025-03006-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To identify the feasibility of using lung ultrasound to determine the position of bronchial blockers in pediatric patients.</p><p><strong>Methods: </strong>In this study, children aged 4-8 years who underwent elective right one-lung ventilation at our hospital between January 2019 and August 2022 were selected. We collected the results of lung ultrasound and fiberoptic bronchoscopy during the placement of bronchial blockers in these children. The accuracy, sensitivity, and specificity of lung ultrasound in determining the position of bronchial blockers were calculated. Additionally, the reproducibility of lung ultrasound in determining the appropriateness of bronchial blockers was also calculated. Furthermore, information regarding whether there were complications associated with lung ultrasound examination or fiberoptic bronchoscopy was also collected.</p><p><strong>Results: </strong>The accuracy of lung ultrasound for determining the position of bronchial blockers was 95.0%. When the position of BBs was appropriate, the sensitivity of lung ultrasound was 96.3% and the specificity was 88.9%. When the position of BBs was too shallow, the sensitivity of lung ultrasound was 75% and the specificity was 96.7%. The reproducibility test of lung ultrasound for determining the position of bronchial blockers had a weighted kappa value of 0.91, P < 0.001. In this study we found 6 children had hypoxemia and 6 children had airway mucosal bleeding during fiberoptic bronchoscopy. And no complications linked to lung ultrasound examination were observed.</p><p><strong>Conclusion: </strong>Lung ultrasound has high accuracy, sensitivity, specificity, and repeatability in determining the position of bronchial blockers. It is a new and safe method to determine the position of bronchial blockers.</p>\",\"PeriodicalId\":9190,\"journal\":{\"name\":\"BMC Anesthesiology\",\"volume\":\"25 1\",\"pages\":\"137\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11927112/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Anesthesiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12871-025-03006-0\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Anesthesiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12871-025-03006-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨利用肺部超声确定小儿支气管阻滞剂位置的可行性。方法:选取2019年1月至2022年8月在我院择期行右肺通气的4-8岁儿童为研究对象。我们收集了这些儿童在放置支气管阻滞剂期间的肺超声和纤维支气管镜检查结果。计算肺超声确定支气管阻滞剂位置的准确性、敏感性和特异性。此外,还计算了肺部超声在确定支气管阻滞剂适宜性方面的再现性。此外,我们还收集了有关肺部超声检查或纤维支气管镜检查是否有并发症的信息。结果:超声诊断支气管阻滞剂位置的准确率为95.0%。当定位合适时,肺超声灵敏度为96.3%,特异度为88.9%。当BBs位置过浅时,肺超声敏感性为75%,特异性为96.7%。肺超声确定支气管阻滞剂位置的重复性试验加权kappa值为0.91,P结论:肺超声确定支气管阻滞剂位置具有较高的准确性、敏感性、特异性和重复性。这是一种新的、安全的确定支气管阻滞剂位置的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Feasibility of lung ultrasound for locating bronchial blockers in pediatric thoracic surgery: a retrospective analysis.

Objective: To identify the feasibility of using lung ultrasound to determine the position of bronchial blockers in pediatric patients.

Methods: In this study, children aged 4-8 years who underwent elective right one-lung ventilation at our hospital between January 2019 and August 2022 were selected. We collected the results of lung ultrasound and fiberoptic bronchoscopy during the placement of bronchial blockers in these children. The accuracy, sensitivity, and specificity of lung ultrasound in determining the position of bronchial blockers were calculated. Additionally, the reproducibility of lung ultrasound in determining the appropriateness of bronchial blockers was also calculated. Furthermore, information regarding whether there were complications associated with lung ultrasound examination or fiberoptic bronchoscopy was also collected.

Results: The accuracy of lung ultrasound for determining the position of bronchial blockers was 95.0%. When the position of BBs was appropriate, the sensitivity of lung ultrasound was 96.3% and the specificity was 88.9%. When the position of BBs was too shallow, the sensitivity of lung ultrasound was 75% and the specificity was 96.7%. The reproducibility test of lung ultrasound for determining the position of bronchial blockers had a weighted kappa value of 0.91, P < 0.001. In this study we found 6 children had hypoxemia and 6 children had airway mucosal bleeding during fiberoptic bronchoscopy. And no complications linked to lung ultrasound examination were observed.

Conclusion: Lung ultrasound has high accuracy, sensitivity, specificity, and repeatability in determining the position of bronchial blockers. It is a new and safe method to determine the position of bronchial blockers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Anesthesiology
BMC Anesthesiology ANESTHESIOLOGY-
CiteScore
3.50
自引率
4.50%
发文量
349
审稿时长
>12 weeks
期刊介绍: BMC Anesthesiology is an open access, peer-reviewed journal that considers articles on all aspects of anesthesiology, critical care, perioperative care and pain management, including clinical and experimental research into anesthetic mechanisms, administration and efficacy, technology and monitoring, and associated economic issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信