基于智能手机的老年人“起床和走”测试自我评估:效度和信度研究。

IF 5 Q1 GERIATRICS & GERONTOLOGY
JMIR Aging Pub Date : 2025-03-21 DOI:10.2196/67322
Melissa Johanna Böttinger, Sabato Mellone, Jochen Klenk, Carl-Philipp Jansen, Marios Stefanakis, Elena Litz, Anastasia Bredenbrock, Jan-Philipp Fischer, Jürgen M Bauer, Clemens Becker, Katharina Gordt-Oesterwind
{"title":"基于智能手机的老年人“起床和走”测试自我评估:效度和信度研究。","authors":"Melissa Johanna Böttinger, Sabato Mellone, Jochen Klenk, Carl-Philipp Jansen, Marios Stefanakis, Elena Litz, Anastasia Bredenbrock, Jan-Philipp Fischer, Jürgen M Bauer, Clemens Becker, Katharina Gordt-Oesterwind","doi":"10.2196/67322","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Timed Up and Go test (TUG) is recommended as an evidence-based tool for measuring physical capacity. Instrumented TUG (iTUG) approaches expand classical supervised clinical applications offering the potential of self-assessment for older adults.</p><p><strong>Objective: </strong>This study aimed to evaluate the concurrent validity and test-retest reliability of a smartphone-based TUG self-assessment \"up&go app.\"</p><p><strong>Methods: </strong>A total of 52 community-dwelling older adults (>67 years old) were recruited. A validated and medically certified system attached with a belt at the lower back was used as a reference system to validate the \"up&go app\" algorithm. The participants repeated the TUG 5 times wearing, a smartphone with the \"up&go app\" in their front trouser pocket and an inertial sensor to test the concurrent validity. A subsample of 37 participants repeated the \"up&go app\" measurement 2 weeks later to examine the test-retest reliability.</p><p><strong>Results: </strong>The correlation between the \"up&go app\" and the reference measurement was r=0.99 for the total test duration and r=0.97 for the 5 single repetitions. Agreement between the 5 repetitions was intraclass correlation coefficient (ICC)=0.9 (0.84-0.94). Leaving out the first repetition, the agreement was ICC=0.95 (0.92-0.97). Test-retest agreement had an ICC=0.79 (0.53-0.9).</p><p><strong>Conclusions: </strong>The duration of 5 repetitions of the TUG test, measured with the pocket-worn \"up&go app,\" was very consistent with the results of a lower-back sensor system, indicating excellent concurrent validity. Participants walked slower in the first round than in the other 4 repetitions within a test run. Test-retest reliability was also excellent. The \"up&go app\" provides a useful smartphone-based approach to measure 5 repetitions of the TUG. The app could be used by older adults as a self-screening and monitoring tool of physical capacity at home and thereby help to early identify functional limitations and take interventions when necessary.</p>","PeriodicalId":36245,"journal":{"name":"JMIR Aging","volume":"8 ","pages":"e67322"},"PeriodicalIF":5.0000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11951819/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Smartphone-Based Timed Up and Go Test Self-Assessment for Older Adults: Validity and Reliability Study.\",\"authors\":\"Melissa Johanna Böttinger, Sabato Mellone, Jochen Klenk, Carl-Philipp Jansen, Marios Stefanakis, Elena Litz, Anastasia Bredenbrock, Jan-Philipp Fischer, Jürgen M Bauer, Clemens Becker, Katharina Gordt-Oesterwind\",\"doi\":\"10.2196/67322\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The Timed Up and Go test (TUG) is recommended as an evidence-based tool for measuring physical capacity. Instrumented TUG (iTUG) approaches expand classical supervised clinical applications offering the potential of self-assessment for older adults.</p><p><strong>Objective: </strong>This study aimed to evaluate the concurrent validity and test-retest reliability of a smartphone-based TUG self-assessment \\\"up&go app.\\\"</p><p><strong>Methods: </strong>A total of 52 community-dwelling older adults (>67 years old) were recruited. A validated and medically certified system attached with a belt at the lower back was used as a reference system to validate the \\\"up&go app\\\" algorithm. The participants repeated the TUG 5 times wearing, a smartphone with the \\\"up&go app\\\" in their front trouser pocket and an inertial sensor to test the concurrent validity. A subsample of 37 participants repeated the \\\"up&go app\\\" measurement 2 weeks later to examine the test-retest reliability.</p><p><strong>Results: </strong>The correlation between the \\\"up&go app\\\" and the reference measurement was r=0.99 for the total test duration and r=0.97 for the 5 single repetitions. Agreement between the 5 repetitions was intraclass correlation coefficient (ICC)=0.9 (0.84-0.94). Leaving out the first repetition, the agreement was ICC=0.95 (0.92-0.97). Test-retest agreement had an ICC=0.79 (0.53-0.9).</p><p><strong>Conclusions: </strong>The duration of 5 repetitions of the TUG test, measured with the pocket-worn \\\"up&go app,\\\" was very consistent with the results of a lower-back sensor system, indicating excellent concurrent validity. Participants walked slower in the first round than in the other 4 repetitions within a test run. Test-retest reliability was also excellent. The \\\"up&go app\\\" provides a useful smartphone-based approach to measure 5 repetitions of the TUG. The app could be used by older adults as a self-screening and monitoring tool of physical capacity at home and thereby help to early identify functional limitations and take interventions when necessary.</p>\",\"PeriodicalId\":36245,\"journal\":{\"name\":\"JMIR Aging\",\"volume\":\"8 \",\"pages\":\"e67322\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2025-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11951819/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JMIR Aging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2196/67322\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"GERIATRICS & GERONTOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Aging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/67322","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GERIATRICS & GERONTOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:计时Up和Go测试(TUG)被推荐为一种基于证据的测量身体能力的工具。仪器TUG (iTUG)方法扩展了经典的监督临床应用,为老年人提供了自我评估的潜力。目的:本研究旨在评估基于智能手机的TUG自评“up&go”应用程序的并发效度和重测信度。方法:共招募52名居住在社区的老年人(年龄在60 ~ 67岁之间)。使用经过验证和医学认证的系统作为参考系统,在背部下方附有腰带,以验证“up&go app”算法。参与者将TUG重复了5次,他们在裤子的前口袋里戴着一个装有“up&go”应用程序的智能手机,并戴着一个惯性传感器来测试同时有效性。一个由37名参与者组成的子样本在两周后重复了“up&go app”测量,以检验测试-重测试的可靠性。结果:“up&go app”与参考测量值在总测试时间上的相关系数为r=0.99,在5次单次重复上的相关系数为r=0.97。5个重复间的类内相关系数(ICC)=0.9(0.84 ~ 0.94)。除去第一次重复,协议是ICC=0.95(0.92-0.97)。复试协议的ICC=0.79(0.53-0.9)。结论:使用口袋携带的“up&go app”测量的TUG测试的5次重复持续时间与下背部传感器系统的结果非常一致,表明具有良好的并发效度。参与者在第一轮中走得比在测试中重复的其他4次要慢。重测信度也很好。“up&go应用程序”提供了一种有用的基于智能手机的方法来测量5次重复的TUG。该应用程序可以被老年人用作在家自我筛查和监测身体能力的工具,从而帮助早期识别功能限制,并在必要时采取干预措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Smartphone-Based Timed Up and Go Test Self-Assessment for Older Adults: Validity and Reliability Study.

Background: The Timed Up and Go test (TUG) is recommended as an evidence-based tool for measuring physical capacity. Instrumented TUG (iTUG) approaches expand classical supervised clinical applications offering the potential of self-assessment for older adults.

Objective: This study aimed to evaluate the concurrent validity and test-retest reliability of a smartphone-based TUG self-assessment "up&go app."

Methods: A total of 52 community-dwelling older adults (>67 years old) were recruited. A validated and medically certified system attached with a belt at the lower back was used as a reference system to validate the "up&go app" algorithm. The participants repeated the TUG 5 times wearing, a smartphone with the "up&go app" in their front trouser pocket and an inertial sensor to test the concurrent validity. A subsample of 37 participants repeated the "up&go app" measurement 2 weeks later to examine the test-retest reliability.

Results: The correlation between the "up&go app" and the reference measurement was r=0.99 for the total test duration and r=0.97 for the 5 single repetitions. Agreement between the 5 repetitions was intraclass correlation coefficient (ICC)=0.9 (0.84-0.94). Leaving out the first repetition, the agreement was ICC=0.95 (0.92-0.97). Test-retest agreement had an ICC=0.79 (0.53-0.9).

Conclusions: The duration of 5 repetitions of the TUG test, measured with the pocket-worn "up&go app," was very consistent with the results of a lower-back sensor system, indicating excellent concurrent validity. Participants walked slower in the first round than in the other 4 repetitions within a test run. Test-retest reliability was also excellent. The "up&go app" provides a useful smartphone-based approach to measure 5 repetitions of the TUG. The app could be used by older adults as a self-screening and monitoring tool of physical capacity at home and thereby help to early identify functional limitations and take interventions when necessary.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JMIR Aging
JMIR Aging Social Sciences-Health (social science)
CiteScore
6.50
自引率
4.10%
发文量
71
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信