Mohamad Adnan Alkhouli, John D Carroll, Aken A Desai, Yu-Rong Gao, Tomnema Xiong, Andrea Natale, Ignacio Inglessis-Azuaje, Bradley P Knight
{"title":"一种新型实时三维心内超声心动图导管指导心脏介入性手术的多中心经验。","authors":"Mohamad Adnan Alkhouli, John D Carroll, Aken A Desai, Yu-Rong Gao, Tomnema Xiong, Andrea Natale, Ignacio Inglessis-Azuaje, Bradley P Knight","doi":"10.1161/JAHA.124.037019","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Recent technologies enable real-time 3-dimensional intracardiac echocardiography (ICE) with the advantages of 2-dimensional ICE and imaging capabilities of transesophageal echocardiography. The purpose of this study is to evaluate the real-world, multicenter safety and performance of a novel 3-dimensional ICE system in a variety of cardiac interventions used in standard clinical practice.</p><p><strong>Methods: </strong>This prospective, multicenter, observational, single-arm study enrolled patients who were scheduled for an invasive cardiac procedure involving guidance with ICE and followed until discharge or ≤48 hours postprocedure. Intracardiac imaging was performed with the 3-dimensional ICE catheter, VeriSight Pro (Philips Inc.). Fluoroscopy was used in all cases and transesophageal echocardiography was used in some cases. The primary safety end point was device-related adverse events. The primary efficacy end point included technical success, imaging success, and clinical success.</p><p><strong>Results: </strong>Between October 2021 and November 2022, 155 patients were enrolled and screened. Percutaneous interventions performed included atrial septal defect/patent foramen ovale closures, left atrial appendage occlusion, catheter ablations, and valve procedures. No adverse events were related to the device or procedure. The technical, imaging, and clinical success rates were 98.7% (95% CI, 95.4%-99.8%), 96.1% (95% CI, 91.8%-98.6%), 94.8% (95% CI, 91.8%-98.6%), respectively. Overall, the VeriSight Pro ICE image quality was assessed to be \"acceptable\" or greater in relation to reference image modality among 96.2% (149 of 155) of procedures.</p><p><strong>Conclusions: </strong>VeriSight ICE imaging is safe and effective in the guidance of a wide variety of percutaneous cardiovascular procedures and has provided successful and high-quality imaging of cardiac structures.</p>","PeriodicalId":54370,"journal":{"name":"Journal of the American Heart Association","volume":" ","pages":"e037019"},"PeriodicalIF":5.0000,"publicationDate":"2025-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multicenter Experience With a Novel Real-Time 3-Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures.\",\"authors\":\"Mohamad Adnan Alkhouli, John D Carroll, Aken A Desai, Yu-Rong Gao, Tomnema Xiong, Andrea Natale, Ignacio Inglessis-Azuaje, Bradley P Knight\",\"doi\":\"10.1161/JAHA.124.037019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Recent technologies enable real-time 3-dimensional intracardiac echocardiography (ICE) with the advantages of 2-dimensional ICE and imaging capabilities of transesophageal echocardiography. The purpose of this study is to evaluate the real-world, multicenter safety and performance of a novel 3-dimensional ICE system in a variety of cardiac interventions used in standard clinical practice.</p><p><strong>Methods: </strong>This prospective, multicenter, observational, single-arm study enrolled patients who were scheduled for an invasive cardiac procedure involving guidance with ICE and followed until discharge or ≤48 hours postprocedure. Intracardiac imaging was performed with the 3-dimensional ICE catheter, VeriSight Pro (Philips Inc.). Fluoroscopy was used in all cases and transesophageal echocardiography was used in some cases. The primary safety end point was device-related adverse events. The primary efficacy end point included technical success, imaging success, and clinical success.</p><p><strong>Results: </strong>Between October 2021 and November 2022, 155 patients were enrolled and screened. Percutaneous interventions performed included atrial septal defect/patent foramen ovale closures, left atrial appendage occlusion, catheter ablations, and valve procedures. No adverse events were related to the device or procedure. The technical, imaging, and clinical success rates were 98.7% (95% CI, 95.4%-99.8%), 96.1% (95% CI, 91.8%-98.6%), 94.8% (95% CI, 91.8%-98.6%), respectively. Overall, the VeriSight Pro ICE image quality was assessed to be \\\"acceptable\\\" or greater in relation to reference image modality among 96.2% (149 of 155) of procedures.</p><p><strong>Conclusions: </strong>VeriSight ICE imaging is safe and effective in the guidance of a wide variety of percutaneous cardiovascular procedures and has provided successful and high-quality imaging of cardiac structures.</p>\",\"PeriodicalId\":54370,\"journal\":{\"name\":\"Journal of the American Heart Association\",\"volume\":\" \",\"pages\":\"e037019\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2025-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Heart Association\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1161/JAHA.124.037019\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Heart Association","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/JAHA.124.037019","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
摘要
背景:最近的技术使实时三维心内超声心动图(ICE)具有二维超声心动图和经食管超声心动图的成像能力的优势。本研究的目的是评估一种新的三维ICE系统在标准临床实践中使用的各种心脏干预措施的真实世界,多中心的安全性和性能。方法:这项前瞻性、多中心、观察性、单臂研究纳入了计划在ICE指导下进行有创心脏手术的患者,并随访至出院或术后≤48小时。心内成像采用三维ICE导管,VeriSight Pro (Philips Inc.)。所有病例均行透视检查,部分病例行经食管超声心动图检查。主要的安全性终点是器械相关的不良事件。主要疗效终点包括技术成功、影像学成功和临床成功。结果:在2021年10月至2022年11月期间,155名患者入组并进行了筛查。经皮介入治疗包括房间隔缺损/卵圆孔未闭关闭、左房耳闭塞、导管消融和瓣膜手术。没有与器械或手术相关的不良事件。技术、影像学和临床成功率分别为98.7% (95% CI, 95.4%-99.8%)、96.1% (95% CI, 91.8%-98.6%)、94.8% (95% CI, 91.8%-98.6%)。总体而言,VeriSight Pro ICE图像质量在96.2%(155个程序中的149个)的参考图像模式中被评估为“可接受”或更高。结论:VeriSight ICE成像在各种经皮心血管手术的指导中是安全有效的,并提供了成功和高质量的心脏结构成像。
Multicenter Experience With a Novel Real-Time 3-Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures.
Background: Recent technologies enable real-time 3-dimensional intracardiac echocardiography (ICE) with the advantages of 2-dimensional ICE and imaging capabilities of transesophageal echocardiography. The purpose of this study is to evaluate the real-world, multicenter safety and performance of a novel 3-dimensional ICE system in a variety of cardiac interventions used in standard clinical practice.
Methods: This prospective, multicenter, observational, single-arm study enrolled patients who were scheduled for an invasive cardiac procedure involving guidance with ICE and followed until discharge or ≤48 hours postprocedure. Intracardiac imaging was performed with the 3-dimensional ICE catheter, VeriSight Pro (Philips Inc.). Fluoroscopy was used in all cases and transesophageal echocardiography was used in some cases. The primary safety end point was device-related adverse events. The primary efficacy end point included technical success, imaging success, and clinical success.
Results: Between October 2021 and November 2022, 155 patients were enrolled and screened. Percutaneous interventions performed included atrial septal defect/patent foramen ovale closures, left atrial appendage occlusion, catheter ablations, and valve procedures. No adverse events were related to the device or procedure. The technical, imaging, and clinical success rates were 98.7% (95% CI, 95.4%-99.8%), 96.1% (95% CI, 91.8%-98.6%), 94.8% (95% CI, 91.8%-98.6%), respectively. Overall, the VeriSight Pro ICE image quality was assessed to be "acceptable" or greater in relation to reference image modality among 96.2% (149 of 155) of procedures.
Conclusions: VeriSight ICE imaging is safe and effective in the guidance of a wide variety of percutaneous cardiovascular procedures and has provided successful and high-quality imaging of cardiac structures.
期刊介绍:
As an Open Access journal, JAHA - Journal of the American Heart Association is rapidly and freely available, accelerating the translation of strong science into effective practice.
JAHA is an authoritative, peer-reviewed Open Access journal focusing on cardiovascular and cerebrovascular disease. JAHA provides a global forum for basic and clinical research and timely reviews on cardiovascular disease and stroke. As an Open Access journal, its content is free on publication to read, download, and share, accelerating the translation of strong science into effective practice.