用定量评估软件评价左乳深吸气屏气照射的再现性

Tomoki Harukuni, Kenji Matsumoto, Kengo Kosaka, Taishi Matsuda
{"title":"用定量评估软件评价左乳深吸气屏气照射的再现性","authors":"Tomoki Harukuni, Kenji Matsumoto, Kengo Kosaka, Taishi Matsuda","doi":"10.6009/jjrt.25-1470","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We developed software that can analyze central lung distance (CLD) and central skin distance (CSD) in deep inspiration breath hold (DIBH) irradiation and verified the reproducibility of the DIBH irradiation method in our hospital.</p><p><strong>Methods: </strong>CLD and CSD were analyzed using In-house software using cine images acquired during treatment; intra- or inter-fractional motion was calculated from the obtained data and compared with other reports using systematic error (ΔΣ) and random error (Δσ).</p><p><strong>Results: </strong>The ΔΣ and Δσ were 1.15 mm and 1.53 mm, respectively, which were the same as those reported in other reports.</p><p><strong>Conclusion: </strong>The reproducibility of the irradiation method for left breast DIBH irradiation at our hospital is considered good. Due to its characteristics, regular and quantitative evaluation is required, and verification and evaluation are required at each facility.</p>","PeriodicalId":74309,"journal":{"name":"Nihon Hoshasen Gijutsu Gakkai zasshi","volume":"81 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Evaluation of Reproducibility in Left Breast Deep Inspiration Breath-hold Irradiation Using Quantitative Assessment Software].\",\"authors\":\"Tomoki Harukuni, Kenji Matsumoto, Kengo Kosaka, Taishi Matsuda\",\"doi\":\"10.6009/jjrt.25-1470\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We developed software that can analyze central lung distance (CLD) and central skin distance (CSD) in deep inspiration breath hold (DIBH) irradiation and verified the reproducibility of the DIBH irradiation method in our hospital.</p><p><strong>Methods: </strong>CLD and CSD were analyzed using In-house software using cine images acquired during treatment; intra- or inter-fractional motion was calculated from the obtained data and compared with other reports using systematic error (ΔΣ) and random error (Δσ).</p><p><strong>Results: </strong>The ΔΣ and Δσ were 1.15 mm and 1.53 mm, respectively, which were the same as those reported in other reports.</p><p><strong>Conclusion: </strong>The reproducibility of the irradiation method for left breast DIBH irradiation at our hospital is considered good. Due to its characteristics, regular and quantitative evaluation is required, and verification and evaluation are required at each facility.</p>\",\"PeriodicalId\":74309,\"journal\":{\"name\":\"Nihon Hoshasen Gijutsu Gakkai zasshi\",\"volume\":\"81 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nihon Hoshasen Gijutsu Gakkai zasshi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.6009/jjrt.25-1470\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Hoshasen Gijutsu Gakkai zasshi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6009/jjrt.25-1470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:开发分析深吸气屏气(DIBH)照射中中心肺距离(CLD)和中心皮肤距离(CSD)的软件,验证DIBH照射方法在我院的可重复性。方法:采用内部软件对治疗过程中拍摄的电影影像进行CLD和CSD分析;从获得的数据中计算分数内或分数间运动,并使用系统误差(ΔΣ)和随机误差(Δσ)与其他报告进行比较。结果:ΔΣ和Δσ分别为1.15 mm和1.53 mm,与其他报道相同。结论:我院左乳DIBH照射方法重复性好。由于其特点,需要定期进行定量评价,并对每个设施进行验证和评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Evaluation of Reproducibility in Left Breast Deep Inspiration Breath-hold Irradiation Using Quantitative Assessment Software].

Purpose: We developed software that can analyze central lung distance (CLD) and central skin distance (CSD) in deep inspiration breath hold (DIBH) irradiation and verified the reproducibility of the DIBH irradiation method in our hospital.

Methods: CLD and CSD were analyzed using In-house software using cine images acquired during treatment; intra- or inter-fractional motion was calculated from the obtained data and compared with other reports using systematic error (ΔΣ) and random error (Δσ).

Results: The ΔΣ and Δσ were 1.15 mm and 1.53 mm, respectively, which were the same as those reported in other reports.

Conclusion: The reproducibility of the irradiation method for left breast DIBH irradiation at our hospital is considered good. Due to its characteristics, regular and quantitative evaluation is required, and verification and evaluation are required at each facility.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信