新型手部灵活性测量设备的临床验证。

PLOS digital health Pub Date : 2025-03-10 eCollection Date: 2025-03-01 DOI:10.1371/journal.pdig.0000744
Conor D Hayden, Bruce P Murphy, Deirdre Gilsenan, Bahman Nasseroleslami, Orla Hardiman, Deirdre Murray
{"title":"新型手部灵活性测量设备的临床验证。","authors":"Conor D Hayden, Bruce P Murphy, Deirdre Gilsenan, Bahman Nasseroleslami, Orla Hardiman, Deirdre Murray","doi":"10.1371/journal.pdig.0000744","DOIUrl":null,"url":null,"abstract":"<p><p>The lack of sensitive objective outcome measures for hand dexterity is a barrier for clinical assessment of neurological conditions and has negatively affected clinical trials. Here, we clinically validate a new method for measuring hand dexterity, a novel hand worn sensor that digitises the Finger Tapping Test. The device was assessed in a cohort of 180 healthy controls and 51 people with Amyotrophic Lateral Sclerosis (ALS) and compared against rating scales and traditional measures (Nine Hole Peg test and grip dynamometry). 14 features were extracted from the device and using a logistic regression algorithm, a 0-100 dexterity performance score was generated for each participant, which accounted for age/sex differences. The device returned objective ratings of a participant's hand dexterity (dominant, non-dominant and overall score). The average overall dexterity performance score in all healthy participants was 88 ± 17 (mean ± standard deviation). The overall dexterity score was statistically significantly worse in participants with ALS (age/sex matched healthy subset: 80 ± 20, ALS: 45 ± 32, p-value < 0.0001). The device also had a higher completion rate, (94% dominant hand) compared to the traditional measures (82% dominant hand). This test and scoring system have been validated and the regression model was developed using a framework that is potentially applicable to any relevant condition. This device could act as an objective outcome measure in clinical trials and may be useful in improving patient care.</p>","PeriodicalId":74465,"journal":{"name":"PLOS digital health","volume":"4 3","pages":"e0000744"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11893126/pdf/","citationCount":"0","resultStr":"{\"title\":\"Clinical validation of a novel hand dexterity measurement device.\",\"authors\":\"Conor D Hayden, Bruce P Murphy, Deirdre Gilsenan, Bahman Nasseroleslami, Orla Hardiman, Deirdre Murray\",\"doi\":\"10.1371/journal.pdig.0000744\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The lack of sensitive objective outcome measures for hand dexterity is a barrier for clinical assessment of neurological conditions and has negatively affected clinical trials. Here, we clinically validate a new method for measuring hand dexterity, a novel hand worn sensor that digitises the Finger Tapping Test. The device was assessed in a cohort of 180 healthy controls and 51 people with Amyotrophic Lateral Sclerosis (ALS) and compared against rating scales and traditional measures (Nine Hole Peg test and grip dynamometry). 14 features were extracted from the device and using a logistic regression algorithm, a 0-100 dexterity performance score was generated for each participant, which accounted for age/sex differences. The device returned objective ratings of a participant's hand dexterity (dominant, non-dominant and overall score). The average overall dexterity performance score in all healthy participants was 88 ± 17 (mean ± standard deviation). The overall dexterity score was statistically significantly worse in participants with ALS (age/sex matched healthy subset: 80 ± 20, ALS: 45 ± 32, p-value < 0.0001). The device also had a higher completion rate, (94% dominant hand) compared to the traditional measures (82% dominant hand). This test and scoring system have been validated and the regression model was developed using a framework that is potentially applicable to any relevant condition. This device could act as an objective outcome measure in clinical trials and may be useful in improving patient care.</p>\",\"PeriodicalId\":74465,\"journal\":{\"name\":\"PLOS digital health\",\"volume\":\"4 3\",\"pages\":\"e0000744\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11893126/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PLOS digital health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1371/journal.pdig.0000744\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PLOS digital health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1371/journal.pdig.0000744","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clinical validation of a novel hand dexterity measurement device.

The lack of sensitive objective outcome measures for hand dexterity is a barrier for clinical assessment of neurological conditions and has negatively affected clinical trials. Here, we clinically validate a new method for measuring hand dexterity, a novel hand worn sensor that digitises the Finger Tapping Test. The device was assessed in a cohort of 180 healthy controls and 51 people with Amyotrophic Lateral Sclerosis (ALS) and compared against rating scales and traditional measures (Nine Hole Peg test and grip dynamometry). 14 features were extracted from the device and using a logistic regression algorithm, a 0-100 dexterity performance score was generated for each participant, which accounted for age/sex differences. The device returned objective ratings of a participant's hand dexterity (dominant, non-dominant and overall score). The average overall dexterity performance score in all healthy participants was 88 ± 17 (mean ± standard deviation). The overall dexterity score was statistically significantly worse in participants with ALS (age/sex matched healthy subset: 80 ± 20, ALS: 45 ± 32, p-value < 0.0001). The device also had a higher completion rate, (94% dominant hand) compared to the traditional measures (82% dominant hand). This test and scoring system have been validated and the regression model was developed using a framework that is potentially applicable to any relevant condition. This device could act as an objective outcome measure in clinical trials and may be useful in improving patient care.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信