Mattia Strazzanti, Caterina Maffeis, Luca Tomasi, Sofia Capocci, Bruna Bolzan, Elena Franchi, Flavio Luciano Ribichini, Giacomo Mugnai
{"title":"被忽视的参数:三尖波E波减速时间作为VDD无铅起搏器房室同步的预测因子。","authors":"Mattia Strazzanti, Caterina Maffeis, Luca Tomasi, Sofia Capocci, Bruna Bolzan, Elena Franchi, Flavio Luciano Ribichini, Giacomo Mugnai","doi":"10.1111/jce.16613","DOIUrl":null,"url":null,"abstract":"<p><p>Leadless pacemakers as the Medtronic Micra AV, have improved cardiac pacing by reducing complications associated with traditional systems. However, achieving high atrioventricular synchrony (AVS) remains a challenge, especially in patients with a high pacing burden. This prospective study enrolled 30 patients to assess the role of echocardiographic parameters in predicting AVS postimplantation. AVS was evaluated via 24-h Holter monitoring, with a median AVS of 67.9% ± 9.6%. Right atrial function, particularly the tricuspidal E wave deceleration time, emerged as the only independent predictor of AVS (p = 0.03), with an AUC of 0.77. These findings suggest that pre-implantation echocardiographic assessment of right atrial parameters could aid in selecting patients who would benefit most from Micra AV. Further studies with larger cohorts and extended follow-ups are warranted.</p>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Neglected Parameter: Tricuspidal E Wave Deceleration Time as Predictor of Atrioventricular Synchrony in VDD Leadless Pacemakers.\",\"authors\":\"Mattia Strazzanti, Caterina Maffeis, Luca Tomasi, Sofia Capocci, Bruna Bolzan, Elena Franchi, Flavio Luciano Ribichini, Giacomo Mugnai\",\"doi\":\"10.1111/jce.16613\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Leadless pacemakers as the Medtronic Micra AV, have improved cardiac pacing by reducing complications associated with traditional systems. However, achieving high atrioventricular synchrony (AVS) remains a challenge, especially in patients with a high pacing burden. This prospective study enrolled 30 patients to assess the role of echocardiographic parameters in predicting AVS postimplantation. AVS was evaluated via 24-h Holter monitoring, with a median AVS of 67.9% ± 9.6%. Right atrial function, particularly the tricuspidal E wave deceleration time, emerged as the only independent predictor of AVS (p = 0.03), with an AUC of 0.77. These findings suggest that pre-implantation echocardiographic assessment of right atrial parameters could aid in selecting patients who would benefit most from Micra AV. Further studies with larger cohorts and extended follow-ups are warranted.</p>\",\"PeriodicalId\":15178,\"journal\":{\"name\":\"Journal of Cardiovascular Electrophysiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Electrophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jce.16613\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jce.16613","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
The Neglected Parameter: Tricuspidal E Wave Deceleration Time as Predictor of Atrioventricular Synchrony in VDD Leadless Pacemakers.
Leadless pacemakers as the Medtronic Micra AV, have improved cardiac pacing by reducing complications associated with traditional systems. However, achieving high atrioventricular synchrony (AVS) remains a challenge, especially in patients with a high pacing burden. This prospective study enrolled 30 patients to assess the role of echocardiographic parameters in predicting AVS postimplantation. AVS was evaluated via 24-h Holter monitoring, with a median AVS of 67.9% ± 9.6%. Right atrial function, particularly the tricuspidal E wave deceleration time, emerged as the only independent predictor of AVS (p = 0.03), with an AUC of 0.77. These findings suggest that pre-implantation echocardiographic assessment of right atrial parameters could aid in selecting patients who would benefit most from Micra AV. Further studies with larger cohorts and extended follow-ups are warranted.
期刊介绍:
Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.