MOZEC西罗莫司洗脱冠状动脉球囊治疗狭窄性冠状动脉病变的安全性和性能:一项真实世界、多中心、上市后监测研究。

IF 1.4 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Cardiology Research Pub Date : 2025-04-01 Epub Date: 2025-02-28 DOI:10.14740/cr2026
Rajendra Kumar Premchand Jain, Keyur Parikh, Selvamani Sethuraman, Kamal Sharma, Sanjeeb Roy, Suryaprakasa Rao Vithala, Kondal Rao Gollamandala, Gobu Packirisamy, Sai Sudhakar Mantravadi, Tomasz Roleder
{"title":"MOZEC西罗莫司洗脱冠状动脉球囊治疗狭窄性冠状动脉病变的安全性和性能:一项真实世界、多中心、上市后监测研究。","authors":"Rajendra Kumar Premchand Jain, Keyur Parikh, Selvamani Sethuraman, Kamal Sharma, Sanjeeb Roy, Suryaprakasa Rao Vithala, Kondal Rao Gollamandala, Gobu Packirisamy, Sai Sudhakar Mantravadi, Tomasz Roleder","doi":"10.14740/cr2026","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Drug-eluting balloons, surface-coated with antiproliferative agents such as sirolimus or paclitaxel, have emerged as an alternative therapeutic option for coronary stenosis. This study evaluated safety and effectiveness of the MOZEC sirolimus-eluting percutaneous transluminal coronary angioplasty (PTCA) balloon dilation catheter (Meril Life Sciences Pvt. Ltd., India) across diverse clinical scenarios in coronary artery stenosis treatment.</p><p><strong>Methods: </strong>A prospective, single-arm, multicenter, real-world, post-marketing surveillance study evaluated the safety and performance of the MOZEC sirolimus-eluting balloon (SEB) in treating native coronary artery disease in daily clinical practice. Patients were followed for 24 months, with clinical visits or telephonic calls at 1, 6, 12, and 24 months after the index procedure. Safety endpoints included major adverse cardiac events (MACEs), and performance endpoints include change in late lumen loss, clinical success, and device success.</p><p><strong>Results: </strong>A total of 141 patients were enrolled in the study. The MOZEC SEB was used in 127 (70.17%) <i>de novo</i> lesions, 40 (22.1%) in-stent restenosis lesions, and 14 (7.73%) bifurcations lesions. Over the 24-month follow-up period (n = 134), six cumulative MACEs (4.47%) were observed, comprising two cardiac deaths (1.49%), five myocardial infarctions (3.73%), and four target lesion revascularizations (2.99%). Late lumen loss analysis included 17 patients who underwent additional coronarography at the 6-month follow-up. In-segment and in-device late lumen loss at 6-month follow-up was 0.14 ± 0.37 mm.</p><p><strong>Conclusions: </strong>The application of MOZEC SEB in various clinical scenarios demonstrated safety and efficacy over long-term follow-up. These findings align with the favorable vessel healing observed during the 6-month imaging follow-up.</p>","PeriodicalId":9424,"journal":{"name":"Cardiology Research","volume":"16 2","pages":"130-139"},"PeriodicalIF":1.4000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11882231/pdf/","citationCount":"0","resultStr":"{\"title\":\"Safety and Performance of the MOZEC Sirolimus-Eluting Coronary Balloon in the Treatment of Stenotic Coronary Artery Lesions: A Real-World, Multicenter, Post-Marketing Surveillance Study.\",\"authors\":\"Rajendra Kumar Premchand Jain, Keyur Parikh, Selvamani Sethuraman, Kamal Sharma, Sanjeeb Roy, Suryaprakasa Rao Vithala, Kondal Rao Gollamandala, Gobu Packirisamy, Sai Sudhakar Mantravadi, Tomasz Roleder\",\"doi\":\"10.14740/cr2026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Drug-eluting balloons, surface-coated with antiproliferative agents such as sirolimus or paclitaxel, have emerged as an alternative therapeutic option for coronary stenosis. This study evaluated safety and effectiveness of the MOZEC sirolimus-eluting percutaneous transluminal coronary angioplasty (PTCA) balloon dilation catheter (Meril Life Sciences Pvt. Ltd., India) across diverse clinical scenarios in coronary artery stenosis treatment.</p><p><strong>Methods: </strong>A prospective, single-arm, multicenter, real-world, post-marketing surveillance study evaluated the safety and performance of the MOZEC sirolimus-eluting balloon (SEB) in treating native coronary artery disease in daily clinical practice. Patients were followed for 24 months, with clinical visits or telephonic calls at 1, 6, 12, and 24 months after the index procedure. Safety endpoints included major adverse cardiac events (MACEs), and performance endpoints include change in late lumen loss, clinical success, and device success.</p><p><strong>Results: </strong>A total of 141 patients were enrolled in the study. The MOZEC SEB was used in 127 (70.17%) <i>de novo</i> lesions, 40 (22.1%) in-stent restenosis lesions, and 14 (7.73%) bifurcations lesions. Over the 24-month follow-up period (n = 134), six cumulative MACEs (4.47%) were observed, comprising two cardiac deaths (1.49%), five myocardial infarctions (3.73%), and four target lesion revascularizations (2.99%). Late lumen loss analysis included 17 patients who underwent additional coronarography at the 6-month follow-up. In-segment and in-device late lumen loss at 6-month follow-up was 0.14 ± 0.37 mm.</p><p><strong>Conclusions: </strong>The application of MOZEC SEB in various clinical scenarios demonstrated safety and efficacy over long-term follow-up. These findings align with the favorable vessel healing observed during the 6-month imaging follow-up.</p>\",\"PeriodicalId\":9424,\"journal\":{\"name\":\"Cardiology Research\",\"volume\":\"16 2\",\"pages\":\"130-139\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11882231/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiology Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14740/cr2026\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14740/cr2026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:药物洗脱球囊,表面包裹抗增殖药物如西罗莫司或紫杉醇,已成为冠状动脉狭窄的另一种治疗选择。本研究评估了MOZEC西罗莫司洗脱经皮腔内冠状动脉成形术(PTCA)球囊扩张导管(Meril Life Sciences Pvt. Ltd., India)在不同临床情况下治疗冠状动脉狭窄的安全性和有效性。方法:一项前瞻性、单臂、多中心、现实世界、上市后监测研究评估了MOZEC西罗莫司洗脱球囊(SEB)在日常临床实践中治疗原发性冠状动脉疾病的安全性和性能。患者随访24个月,分别于术后1、6、12和24个月进行临床访问或电话随访。安全性终点包括主要不良心脏事件(mace),性能终点包括晚期管腔损失的变化、临床成功和器械成功。结果:共有141例患者入组。MOZEC SEB用于127例(70.17%)新发病变,40例(22.1%)支架内再狭窄病变和14例(7.73%)分叉病变。在24个月的随访期间(n = 134),观察到6例累积mace(4.47%),包括2例心源性死亡(1.49%),5例心肌梗死(3.73%),4例靶区血管重建术(2.99%)。晚期管腔损失分析包括17例患者,他们在6个月的随访中接受了额外的冠状造影。在6个月的随访中,节段内和装置内的晚期管腔损失为0.14±0.37 mm。结论:在长期随访中,MOZEC SEB在各种临床情况下的应用显示出安全性和有效性。这些发现与6个月影像学随访期间观察到的良好血管愈合一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Safety and Performance of the MOZEC Sirolimus-Eluting Coronary Balloon in the Treatment of Stenotic Coronary Artery Lesions: A Real-World, Multicenter, Post-Marketing Surveillance Study.

Background: Drug-eluting balloons, surface-coated with antiproliferative agents such as sirolimus or paclitaxel, have emerged as an alternative therapeutic option for coronary stenosis. This study evaluated safety and effectiveness of the MOZEC sirolimus-eluting percutaneous transluminal coronary angioplasty (PTCA) balloon dilation catheter (Meril Life Sciences Pvt. Ltd., India) across diverse clinical scenarios in coronary artery stenosis treatment.

Methods: A prospective, single-arm, multicenter, real-world, post-marketing surveillance study evaluated the safety and performance of the MOZEC sirolimus-eluting balloon (SEB) in treating native coronary artery disease in daily clinical practice. Patients were followed for 24 months, with clinical visits or telephonic calls at 1, 6, 12, and 24 months after the index procedure. Safety endpoints included major adverse cardiac events (MACEs), and performance endpoints include change in late lumen loss, clinical success, and device success.

Results: A total of 141 patients were enrolled in the study. The MOZEC SEB was used in 127 (70.17%) de novo lesions, 40 (22.1%) in-stent restenosis lesions, and 14 (7.73%) bifurcations lesions. Over the 24-month follow-up period (n = 134), six cumulative MACEs (4.47%) were observed, comprising two cardiac deaths (1.49%), five myocardial infarctions (3.73%), and four target lesion revascularizations (2.99%). Late lumen loss analysis included 17 patients who underwent additional coronarography at the 6-month follow-up. In-segment and in-device late lumen loss at 6-month follow-up was 0.14 ± 0.37 mm.

Conclusions: The application of MOZEC SEB in various clinical scenarios demonstrated safety and efficacy over long-term follow-up. These findings align with the favorable vessel healing observed during the 6-month imaging follow-up.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiology Research
Cardiology Research CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.50
自引率
0.00%
发文量
42
期刊介绍: Cardiology Research is an open access, peer-reviewed, international journal. All submissions relating to basic research and clinical practice of cardiology and cardiovascular medicine are in this journal''s scope. This journal focuses on publishing original research and observations in all cardiovascular medicine aspects. Manuscript types include original article, review, case report, short communication, book review, letter to the editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信