Patryk Pozowski, Mateusz Bilski, Maciej Bedrylo, Paweł Sitny, Urszula Zaleska-Dorobisz
{"title":"诊断肝脏脂肪变性和纤维化的现代超声技术:以活检比较为重点的系统综述。","authors":"Patryk Pozowski, Mateusz Bilski, Maciej Bedrylo, Paweł Sitny, Urszula Zaleska-Dorobisz","doi":"10.4254/wjh.v17.i2.100033","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This review evaluated the diagnostic effectiveness of various ultrasound (US) methods compared to liver biopsy.</p><p><strong>Aim: </strong>To determine the diagnostic accuracy of US techniques in assessing liver fibrosis and steatosis in adults, using the area under the receiver operating characteristic curve (AUROC) as the standard measure.</p><p><strong>Methods: </strong>The review included original retrospective or prospective studies published in the last three years in peer-reviewed medical journals, that reported AUROC values. Studies were identified through PubMed searches on January 3 and April 30, 2024. Quality was assessed using the QUADAS-2 tool. Results were tabulated according to the diagnostic method and the type of liver pathology.</p><p><strong>Results: </strong>The review included 52 studies. For liver fibrosis detection, 2D-shear wave elastography (SWE) AUROCs ranged from 0.54 to 0.994, showing better accuracy for advanced stages. Modifications, including 2D-SWE with propagation map guidance and supersonic imagine achieved AUROCs of 0.84 to nearly 1.0. point SWE and classical SWE had AUROCs of 0.741-0.99, and 0.507-0.995, respectively. Transient elastography (TE), visual TE, vibration-controlled TE (VCTE), and FibroTouch reported AUROCs close to 1.0. For steatosis, VCTE with controlled attenuation parameter showed AUROCs up to 0.89 (for ≥ S1), acoustic radiation force impulse ranged from 0.762 to 0.784, US attenuation parameter from 0.88 to 0.93, and normalized local variance measurement from 0.583 to 0.875. Most studies had a low risk of bias across all or most domains, but evidence was limited by variability in study quality and small sample sizes. Innovative SWE variants were evaluated in a single study.</p><p><strong>Conclusion: </strong>Modern US techniques can serve as effective noninvasive diagnostic tools for liver fibrosis and steatosis, with the potential to reduce the reliance on biopsies.</p>","PeriodicalId":23687,"journal":{"name":"World Journal of Hepatology","volume":"17 2","pages":"100033"},"PeriodicalIF":2.5000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11866135/pdf/","citationCount":"0","resultStr":"{\"title\":\"Modern ultrasound techniques for diagnosing liver steatosis and fibrosis: A systematic review with a focus on biopsy comparison.\",\"authors\":\"Patryk Pozowski, Mateusz Bilski, Maciej Bedrylo, Paweł Sitny, Urszula Zaleska-Dorobisz\",\"doi\":\"10.4254/wjh.v17.i2.100033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>This review evaluated the diagnostic effectiveness of various ultrasound (US) methods compared to liver biopsy.</p><p><strong>Aim: </strong>To determine the diagnostic accuracy of US techniques in assessing liver fibrosis and steatosis in adults, using the area under the receiver operating characteristic curve (AUROC) as the standard measure.</p><p><strong>Methods: </strong>The review included original retrospective or prospective studies published in the last three years in peer-reviewed medical journals, that reported AUROC values. Studies were identified through PubMed searches on January 3 and April 30, 2024. Quality was assessed using the QUADAS-2 tool. Results were tabulated according to the diagnostic method and the type of liver pathology.</p><p><strong>Results: </strong>The review included 52 studies. For liver fibrosis detection, 2D-shear wave elastography (SWE) AUROCs ranged from 0.54 to 0.994, showing better accuracy for advanced stages. Modifications, including 2D-SWE with propagation map guidance and supersonic imagine achieved AUROCs of 0.84 to nearly 1.0. point SWE and classical SWE had AUROCs of 0.741-0.99, and 0.507-0.995, respectively. Transient elastography (TE), visual TE, vibration-controlled TE (VCTE), and FibroTouch reported AUROCs close to 1.0. For steatosis, VCTE with controlled attenuation parameter showed AUROCs up to 0.89 (for ≥ S1), acoustic radiation force impulse ranged from 0.762 to 0.784, US attenuation parameter from 0.88 to 0.93, and normalized local variance measurement from 0.583 to 0.875. Most studies had a low risk of bias across all or most domains, but evidence was limited by variability in study quality and small sample sizes. Innovative SWE variants were evaluated in a single study.</p><p><strong>Conclusion: </strong>Modern US techniques can serve as effective noninvasive diagnostic tools for liver fibrosis and steatosis, with the potential to reduce the reliance on biopsies.</p>\",\"PeriodicalId\":23687,\"journal\":{\"name\":\"World Journal of Hepatology\",\"volume\":\"17 2\",\"pages\":\"100033\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2025-02-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11866135/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World Journal of Hepatology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4254/wjh.v17.i2.100033\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Hepatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4254/wjh.v17.i2.100033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Modern ultrasound techniques for diagnosing liver steatosis and fibrosis: A systematic review with a focus on biopsy comparison.
Background: This review evaluated the diagnostic effectiveness of various ultrasound (US) methods compared to liver biopsy.
Aim: To determine the diagnostic accuracy of US techniques in assessing liver fibrosis and steatosis in adults, using the area under the receiver operating characteristic curve (AUROC) as the standard measure.
Methods: The review included original retrospective or prospective studies published in the last three years in peer-reviewed medical journals, that reported AUROC values. Studies were identified through PubMed searches on January 3 and April 30, 2024. Quality was assessed using the QUADAS-2 tool. Results were tabulated according to the diagnostic method and the type of liver pathology.
Results: The review included 52 studies. For liver fibrosis detection, 2D-shear wave elastography (SWE) AUROCs ranged from 0.54 to 0.994, showing better accuracy for advanced stages. Modifications, including 2D-SWE with propagation map guidance and supersonic imagine achieved AUROCs of 0.84 to nearly 1.0. point SWE and classical SWE had AUROCs of 0.741-0.99, and 0.507-0.995, respectively. Transient elastography (TE), visual TE, vibration-controlled TE (VCTE), and FibroTouch reported AUROCs close to 1.0. For steatosis, VCTE with controlled attenuation parameter showed AUROCs up to 0.89 (for ≥ S1), acoustic radiation force impulse ranged from 0.762 to 0.784, US attenuation parameter from 0.88 to 0.93, and normalized local variance measurement from 0.583 to 0.875. Most studies had a low risk of bias across all or most domains, but evidence was limited by variability in study quality and small sample sizes. Innovative SWE variants were evaluated in a single study.
Conclusion: Modern US techniques can serve as effective noninvasive diagnostic tools for liver fibrosis and steatosis, with the potential to reduce the reliance on biopsies.