Alison Delaney, Evangelos I Kritsotakis, Kevin Horner, Steve Kitchen, Jennifer Sedcole, Ted Baxter, Rhona M Maclean, Michael Makris, Clare V Samuelson
{"title":"难治性月经大出血手术治疗中女性血小板功能障碍的高发率","authors":"Alison Delaney, Evangelos I Kritsotakis, Kevin Horner, Steve Kitchen, Jennifer Sedcole, Ted Baxter, Rhona M Maclean, Michael Makris, Clare V Samuelson","doi":"10.1111/hae.70016","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Heavy menstrual bleeding (HMB) is a common presenting symptom in women with bleeding disorders, yet haemostatic testing is sometimes overlooked, even when refractory HMB requires surgical intervention.</p><p><strong>Aim: </strong>To determine the prevalence of bleeding disorders in women referred for surgical management of HMB and investigate screening approaches for bleeding disorders in this population.</p><p><strong>Methods: </strong>Women with refractory HMB referred for surgical management were enrolled prospectively and underwent a detailed haemostatic investigation. The International Society on Thrombosis and Haemostasis Bleeding Assessment Tool (ISTH-BAT) and PFA-100 assay were interrogated as screening tools for bleeding disorders. Multiplate whole blood impedance aggregometry (WBIA) was compared to the current gold-standard lumiaggregometry testing for platelet dysfunction.</p><p><strong>Results: </strong>Fifty women underwent laboratory testing. Sixteen percent (95% confidence interval [CI] 7.2%-29.1%) were diagnosed with platelet function defects based on persistently abnormal lumiaggregometry results. No other clinically significant abnormalities were diagnosed. Women were more likely to be diagnosed with platelet dysfunction if they had failed a greater number of prior therapies, particularly prior endometrial ablation. The ISTH-BAT lacked diagnostic accuracy, even at the calculated optimal cutoff value, and PFA-100 assay lacked sensitivity. Multiplate WBIA was inferior to lumiaggregometry for the detection of platelet function disorders, with sensitivity of 62.5% (95% CI 24.5%-91.5%) and specificity of 87.5% (95% CI 73.2%-95.8%).</p><p><strong>Conclusion: </strong>Study findings support platelet function analysis by lumiaggregometry in women with refractory HMB requiring surgery. Accurate diagnosis would allow targeted haemostatic therapy and implementation of additional perioperative safety measures if surgery is still required.</p>","PeriodicalId":12819,"journal":{"name":"Haemophilia","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High Prevalence of Platelet Function Disorders in Women Referred for Surgical Management of Refractory Heavy Menstrual Bleeding.\",\"authors\":\"Alison Delaney, Evangelos I Kritsotakis, Kevin Horner, Steve Kitchen, Jennifer Sedcole, Ted Baxter, Rhona M Maclean, Michael Makris, Clare V Samuelson\",\"doi\":\"10.1111/hae.70016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Heavy menstrual bleeding (HMB) is a common presenting symptom in women with bleeding disorders, yet haemostatic testing is sometimes overlooked, even when refractory HMB requires surgical intervention.</p><p><strong>Aim: </strong>To determine the prevalence of bleeding disorders in women referred for surgical management of HMB and investigate screening approaches for bleeding disorders in this population.</p><p><strong>Methods: </strong>Women with refractory HMB referred for surgical management were enrolled prospectively and underwent a detailed haemostatic investigation. The International Society on Thrombosis and Haemostasis Bleeding Assessment Tool (ISTH-BAT) and PFA-100 assay were interrogated as screening tools for bleeding disorders. Multiplate whole blood impedance aggregometry (WBIA) was compared to the current gold-standard lumiaggregometry testing for platelet dysfunction.</p><p><strong>Results: </strong>Fifty women underwent laboratory testing. Sixteen percent (95% confidence interval [CI] 7.2%-29.1%) were diagnosed with platelet function defects based on persistently abnormal lumiaggregometry results. No other clinically significant abnormalities were diagnosed. Women were more likely to be diagnosed with platelet dysfunction if they had failed a greater number of prior therapies, particularly prior endometrial ablation. The ISTH-BAT lacked diagnostic accuracy, even at the calculated optimal cutoff value, and PFA-100 assay lacked sensitivity. Multiplate WBIA was inferior to lumiaggregometry for the detection of platelet function disorders, with sensitivity of 62.5% (95% CI 24.5%-91.5%) and specificity of 87.5% (95% CI 73.2%-95.8%).</p><p><strong>Conclusion: </strong>Study findings support platelet function analysis by lumiaggregometry in women with refractory HMB requiring surgery. Accurate diagnosis would allow targeted haemostatic therapy and implementation of additional perioperative safety measures if surgery is still required.</p>\",\"PeriodicalId\":12819,\"journal\":{\"name\":\"Haemophilia\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Haemophilia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/hae.70016\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Haemophilia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/hae.70016","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
大量月经出血(HMB)是女性出血性疾病的常见症状,但止血试验有时被忽视,即使难治性HMB需要手术干预。目的:确定接受HMB手术治疗的女性出血性疾病的患病率,并研究该人群中出血性疾病的筛查方法。方法:前瞻性纳入难治性HMB患者,进行详细的止血调查。国际血栓和止血学会出血评估工具(ISTH-BAT)和PFA-100检测被作为出血性疾病的筛查工具。将多板全血阻抗聚集试验(WBIA)与目前血小板功能障碍的金标准光聚集试验进行比较。结果:50名妇女接受了实验室检查。16%(95%可信区间[CI] 7.2%-29.1%)的患者根据持续异常的光度测定结果被诊断为血小板功能缺陷。未发现其他有临床意义的异常。如果女性之前的治疗失败,尤其是子宫内膜消融,她们更有可能被诊断为血小板功能障碍。即使在计算的最佳截止值下,ISTH-BAT也缺乏诊断准确性,而PFA-100检测缺乏灵敏度。多板WBIA检测血小板功能障碍的灵敏度为62.5% (95% CI 24.5% ~ 91.5%),特异性为87.5% (95% CI 73.2% ~ 95.8%),低于光聚集法。结论:研究结果支持在需要手术治疗的难治性HMB患者中应用聚光度法分析血小板功能。准确的诊断将允许有针对性的止血治疗和实施额外的围手术期安全措施,如果仍然需要手术。
High Prevalence of Platelet Function Disorders in Women Referred for Surgical Management of Refractory Heavy Menstrual Bleeding.
Introduction: Heavy menstrual bleeding (HMB) is a common presenting symptom in women with bleeding disorders, yet haemostatic testing is sometimes overlooked, even when refractory HMB requires surgical intervention.
Aim: To determine the prevalence of bleeding disorders in women referred for surgical management of HMB and investigate screening approaches for bleeding disorders in this population.
Methods: Women with refractory HMB referred for surgical management were enrolled prospectively and underwent a detailed haemostatic investigation. The International Society on Thrombosis and Haemostasis Bleeding Assessment Tool (ISTH-BAT) and PFA-100 assay were interrogated as screening tools for bleeding disorders. Multiplate whole blood impedance aggregometry (WBIA) was compared to the current gold-standard lumiaggregometry testing for platelet dysfunction.
Results: Fifty women underwent laboratory testing. Sixteen percent (95% confidence interval [CI] 7.2%-29.1%) were diagnosed with platelet function defects based on persistently abnormal lumiaggregometry results. No other clinically significant abnormalities were diagnosed. Women were more likely to be diagnosed with platelet dysfunction if they had failed a greater number of prior therapies, particularly prior endometrial ablation. The ISTH-BAT lacked diagnostic accuracy, even at the calculated optimal cutoff value, and PFA-100 assay lacked sensitivity. Multiplate WBIA was inferior to lumiaggregometry for the detection of platelet function disorders, with sensitivity of 62.5% (95% CI 24.5%-91.5%) and specificity of 87.5% (95% CI 73.2%-95.8%).
Conclusion: Study findings support platelet function analysis by lumiaggregometry in women with refractory HMB requiring surgery. Accurate diagnosis would allow targeted haemostatic therapy and implementation of additional perioperative safety measures if surgery is still required.
期刊介绍:
Haemophilia is an international journal dedicated to the exchange of information regarding the comprehensive care of haemophilia. The Journal contains review articles, original scientific papers and case reports related to haemophilia care, with frequent supplements. Subjects covered include:
clotting factor deficiencies, both inherited and acquired: haemophilia A, B, von Willebrand''s disease, deficiencies of factor V, VII, X and XI
replacement therapy for clotting factor deficiencies
component therapy in the developing world
transfusion transmitted disease
haemophilia care and paediatrics, orthopaedics, gynaecology and obstetrics
nursing
laboratory diagnosis
carrier detection
psycho-social concerns
economic issues
audit
inherited platelet disorders.