【无针胰岛素注射完成率及注射性能的实验研究】。

Q4 Medicine
Yang Zhu, Can Kang, Wei Cai, Chao Huang
{"title":"【无针胰岛素注射完成率及注射性能的实验研究】。","authors":"Yang Zhu, Can Kang, Wei Cai, Chao Huang","doi":"10.7507/1001-5515.202406035","DOIUrl":null,"url":null,"abstract":"<p><p>As a relatively novel technique for drug delivery, the needle-free injection technique is characterized by transporting the drug liquid to the designated subcutaneous position through a high-speed micro-jet. Although this technique has been applied in many fields, the research on its drug dispersion mechanism and injection performance is insufficient. The presented study aims to identify critical parameters during the injection process and describe their influence on the injection effect. The injection completion rate and performance of a needle-free injector under various operating conditions were compared based on mouse experiments. The results show that the nozzle diameter imposes a more significant influence on jet characteristics than other injection parameters. Moreover, the injection completion rate increases with the nozzle diameter. The nozzle diameters of 0.14 mm and 0.25 mm correspond to injection completion rates of 89.7% and 95.8%, respectively. Furthermore, by analyzing the rate of blood glucose change in the tested mice, it is found that insulin administration through the needle-free injection can achieve a drug effect duration longer than 120 min, which is better than that obtained using conventional needle-syringe technique. In summary, the obtained conclusions can provide an important reference for the optimal design and extending application of the air-powered needle-free injector.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"42 1","pages":"181-188"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11955342/pdf/","citationCount":"0","resultStr":"{\"title\":\"[Experimental study on injection completion rate and performance for needle-free insulin injection].\",\"authors\":\"Yang Zhu, Can Kang, Wei Cai, Chao Huang\",\"doi\":\"10.7507/1001-5515.202406035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>As a relatively novel technique for drug delivery, the needle-free injection technique is characterized by transporting the drug liquid to the designated subcutaneous position through a high-speed micro-jet. Although this technique has been applied in many fields, the research on its drug dispersion mechanism and injection performance is insufficient. The presented study aims to identify critical parameters during the injection process and describe their influence on the injection effect. The injection completion rate and performance of a needle-free injector under various operating conditions were compared based on mouse experiments. The results show that the nozzle diameter imposes a more significant influence on jet characteristics than other injection parameters. Moreover, the injection completion rate increases with the nozzle diameter. The nozzle diameters of 0.14 mm and 0.25 mm correspond to injection completion rates of 89.7% and 95.8%, respectively. Furthermore, by analyzing the rate of blood glucose change in the tested mice, it is found that insulin administration through the needle-free injection can achieve a drug effect duration longer than 120 min, which is better than that obtained using conventional needle-syringe technique. In summary, the obtained conclusions can provide an important reference for the optimal design and extending application of the air-powered needle-free injector.</p>\",\"PeriodicalId\":39324,\"journal\":{\"name\":\"生物医学工程学杂志\",\"volume\":\"42 1\",\"pages\":\"181-188\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11955342/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"生物医学工程学杂志\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.7507/1001-5515.202406035\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"生物医学工程学杂志","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.7507/1001-5515.202406035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

无针注射技术是一种相对较新的给药技术,其特点是通过高速微射流将药液输送到指定的皮下位置。虽然该技术在许多领域得到了应用,但对其药物分散机制和注射性能的研究还很不足。本研究旨在确定注射过程中的关键参数,并描述它们对注射效果的影响。在小鼠实验的基础上,比较了不同操作条件下无针注射器的注射完成率和注射性能。结果表明,喷嘴直径对射流特性的影响比其他喷射参数更为显著。此外,注射完井率随喷嘴直径的增大而增大。喷嘴直径为0.14 mm和0.25 mm时,注射完成率分别为89.7%和95.8%。此外,通过对实验小鼠血糖变化率的分析,发现无针注射胰岛素的药效持续时间超过120 min,优于传统的针注射技术。所得结论可为气动无针注射器的优化设计和推广应用提供重要参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Experimental study on injection completion rate and performance for needle-free insulin injection].

As a relatively novel technique for drug delivery, the needle-free injection technique is characterized by transporting the drug liquid to the designated subcutaneous position through a high-speed micro-jet. Although this technique has been applied in many fields, the research on its drug dispersion mechanism and injection performance is insufficient. The presented study aims to identify critical parameters during the injection process and describe their influence on the injection effect. The injection completion rate and performance of a needle-free injector under various operating conditions were compared based on mouse experiments. The results show that the nozzle diameter imposes a more significant influence on jet characteristics than other injection parameters. Moreover, the injection completion rate increases with the nozzle diameter. The nozzle diameters of 0.14 mm and 0.25 mm correspond to injection completion rates of 89.7% and 95.8%, respectively. Furthermore, by analyzing the rate of blood glucose change in the tested mice, it is found that insulin administration through the needle-free injection can achieve a drug effect duration longer than 120 min, which is better than that obtained using conventional needle-syringe technique. In summary, the obtained conclusions can provide an important reference for the optimal design and extending application of the air-powered needle-free injector.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
生物医学工程学杂志
生物医学工程学杂志 Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
4868
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信