葡萄糖操作程序对连续血糖监测系统的标准化性能评估的可行性。

IF 4.1 Q2 ENDOCRINOLOGY & METABOLISM
Manuela Link, Manuel Eichenlaub, Delia Waldenmaier, Stephanie Wehrstedt, Stefan Pleus, Nina Jendrike, Sükrü Öter, Cornelia Haug, Stefanie Hossmann, Martina Rothenbühler, Derek Brandt, Guido Freckmann
{"title":"葡萄糖操作程序对连续血糖监测系统的标准化性能评估的可行性。","authors":"Manuela Link, Manuel Eichenlaub, Delia Waldenmaier, Stephanie Wehrstedt, Stefan Pleus, Nina Jendrike, Sükrü Öter, Cornelia Haug, Stefanie Hossmann, Martina Rothenbühler, Derek Brandt, Guido Freckmann","doi":"10.1177/19322968251317526","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In continuous glucose monitoring (CGM) system performance studies, it is common to implement specific procedures for manipulating the participants' blood glucose (BG) levels during the collection of comparator BG measurements. Recently, such a procedure was proposed by a group of experts, and this study assessed its ability to produce combinations of BG levels and rates of change (RoCs) with certain characteristics.</p><p><strong>Methods: </strong>During three separate in-clinic sessions conducted over 15 days, capillary BG measurements were carried out every 15 minutes for 7 hours. Simultaneously, the participants' BG levels were manipulated by controlling food intake and insulin administration to induce transient hyperglycemia and hypoglycemia. Subsequently, the combinations of BG levels and RoCs were categorized into dynamic glucose regions distinguishing between rapidly increasing BG levels (Alert high), hyperglycemia (BG high), rapidly falling BG levels (Alert low), and hypoglycemia (BG low).</p><p><strong>Results: </strong>A total of 24 adult participants with type 1 diabetes were included. Capillary BG-RoC combinations showed 7.5% in the Alert high region, 13.3% in the BG high region, 9.8% in the Alert low region, and 11.0% in the BG low region. No adverse events related to the glucose manipulation procedure were documented.</p><p><strong>Conclusions: </strong>As recommended by the experts, the percentage of data points in regions was ≥7.5%, demonstrating the procedure's feasibility. However, given that the recommendation for the alert high region was only barely achieved, we suggest optimizations to the procedure and definition of dynamic glucose regions to facilitate the procedures' adoption in standardized CGM performance evaluations.</p>","PeriodicalId":15475,"journal":{"name":"Journal of Diabetes Science and Technology","volume":" ","pages":"19322968251317526"},"PeriodicalIF":4.1000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11848859/pdf/","citationCount":"0","resultStr":"{\"title\":\"Feasibility of a Glucose Manipulation Procedure for the Standardized Performance Evaluation of Continuous Glucose Monitoring Systems.\",\"authors\":\"Manuela Link, Manuel Eichenlaub, Delia Waldenmaier, Stephanie Wehrstedt, Stefan Pleus, Nina Jendrike, Sükrü Öter, Cornelia Haug, Stefanie Hossmann, Martina Rothenbühler, Derek Brandt, Guido Freckmann\",\"doi\":\"10.1177/19322968251317526\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In continuous glucose monitoring (CGM) system performance studies, it is common to implement specific procedures for manipulating the participants' blood glucose (BG) levels during the collection of comparator BG measurements. Recently, such a procedure was proposed by a group of experts, and this study assessed its ability to produce combinations of BG levels and rates of change (RoCs) with certain characteristics.</p><p><strong>Methods: </strong>During three separate in-clinic sessions conducted over 15 days, capillary BG measurements were carried out every 15 minutes for 7 hours. Simultaneously, the participants' BG levels were manipulated by controlling food intake and insulin administration to induce transient hyperglycemia and hypoglycemia. Subsequently, the combinations of BG levels and RoCs were categorized into dynamic glucose regions distinguishing between rapidly increasing BG levels (Alert high), hyperglycemia (BG high), rapidly falling BG levels (Alert low), and hypoglycemia (BG low).</p><p><strong>Results: </strong>A total of 24 adult participants with type 1 diabetes were included. Capillary BG-RoC combinations showed 7.5% in the Alert high region, 13.3% in the BG high region, 9.8% in the Alert low region, and 11.0% in the BG low region. No adverse events related to the glucose manipulation procedure were documented.</p><p><strong>Conclusions: </strong>As recommended by the experts, the percentage of data points in regions was ≥7.5%, demonstrating the procedure's feasibility. However, given that the recommendation for the alert high region was only barely achieved, we suggest optimizations to the procedure and definition of dynamic glucose regions to facilitate the procedures' adoption in standardized CGM performance evaluations.</p>\",\"PeriodicalId\":15475,\"journal\":{\"name\":\"Journal of Diabetes Science and Technology\",\"volume\":\" \",\"pages\":\"19322968251317526\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2025-02-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11848859/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Diabetes Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/19322968251317526\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Diabetes Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19322968251317526","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

背景:在连续血糖监测(CGM)系统性能研究中,通常在收集比较器血糖测量值期间实施特定程序来操纵参与者的血糖(BG)水平。最近,一组专家提出了这种方法,本研究评估了其产生具有某些特征的BG水平和变化率(roc)组合的能力。方法:在为期15天的三个单独的临床疗程中,每15分钟进行一次毛细血管BG测量,持续7小时。同时,通过控制食物摄入和胰岛素给药来控制参与者的血糖水平,以诱导短暂的高血糖和低血糖。随后,将BG水平和roc的组合分为动态葡萄糖区,区分快速升高的BG水平(高警戒)、高血糖(高血糖)、快速下降的BG水平(低警戒)和低血糖(低血糖)。结果:共纳入24名成人1型糖尿病患者。毛细血管BG- roc组合在Alert high区为7.5%,BG high区为13.3%,Alert low区为9.8%,BG low区为11.0%。没有记录与葡萄糖操作过程相关的不良事件。结论:根据专家建议,区域数据点百分比≥7.5%,说明该方法是可行的。然而,鉴于警戒高区域的建议仅勉强实现,我们建议对程序和动态葡萄糖区域的定义进行优化,以促进该程序在标准化CGM绩效评估中的采用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Feasibility of a Glucose Manipulation Procedure for the Standardized Performance Evaluation of Continuous Glucose Monitoring Systems.

Background: In continuous glucose monitoring (CGM) system performance studies, it is common to implement specific procedures for manipulating the participants' blood glucose (BG) levels during the collection of comparator BG measurements. Recently, such a procedure was proposed by a group of experts, and this study assessed its ability to produce combinations of BG levels and rates of change (RoCs) with certain characteristics.

Methods: During three separate in-clinic sessions conducted over 15 days, capillary BG measurements were carried out every 15 minutes for 7 hours. Simultaneously, the participants' BG levels were manipulated by controlling food intake and insulin administration to induce transient hyperglycemia and hypoglycemia. Subsequently, the combinations of BG levels and RoCs were categorized into dynamic glucose regions distinguishing between rapidly increasing BG levels (Alert high), hyperglycemia (BG high), rapidly falling BG levels (Alert low), and hypoglycemia (BG low).

Results: A total of 24 adult participants with type 1 diabetes were included. Capillary BG-RoC combinations showed 7.5% in the Alert high region, 13.3% in the BG high region, 9.8% in the Alert low region, and 11.0% in the BG low region. No adverse events related to the glucose manipulation procedure were documented.

Conclusions: As recommended by the experts, the percentage of data points in regions was ≥7.5%, demonstrating the procedure's feasibility. However, given that the recommendation for the alert high region was only barely achieved, we suggest optimizations to the procedure and definition of dynamic glucose regions to facilitate the procedures' adoption in standardized CGM performance evaluations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Diabetes Science and Technology
Journal of Diabetes Science and Technology Medicine-Internal Medicine
CiteScore
7.50
自引率
12.00%
发文量
148
期刊介绍: The Journal of Diabetes Science and Technology (JDST) is a bi-monthly, peer-reviewed scientific journal published by the Diabetes Technology Society. JDST covers scientific and clinical aspects of diabetes technology including glucose monitoring, insulin and metabolic peptide delivery, the artificial pancreas, digital health, precision medicine, social media, cybersecurity, software for modeling, physiologic monitoring, technology for managing obesity, and diagnostic tests of glycation. The journal also covers the development and use of mobile applications and wireless communication, as well as bioengineered tools such as MEMS, new biomaterials, and nanotechnology to develop new sensors. Articles in JDST cover both basic research and clinical applications of technologies being developed to help people with diabetes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信