Zhiyuan Feng , Jiao Li , Keqi Huang , Guoqiang Liu , Huanhuan Bai , Xin Huang , Jun Qi , Zhengwei Tang , Penghai Xu , Xiaofei Yang , Zheng Qu , Guozhe Meng
{"title":"用于铝合金 3003 长效防腐蚀保护的 PDA 改性溶胶凝胶涂层","authors":"Zhiyuan Feng , Jiao Li , Keqi Huang , Guoqiang Liu , Huanhuan Bai , Xin Huang , Jun Qi , Zhengwei Tang , Penghai Xu , Xiaofei Yang , Zheng Qu , Guozhe Meng","doi":"10.1016/j.corcom.2023.11.006","DOIUrl":null,"url":null,"abstract":"<div><div>Within the realm of corrosion protection methods for Al alloys, sol-gel technique has garnered increasing attention. However, conventional sol-gel methodologies cannot provide adequate long-lasting corrosion protection to Al alloys when exposed to chloride-rich solutions. This paper introduces an innovative approach to substantially augment the corrosion resistance of aluminum alloys through utilization of polydopamine (PDA)-modified sol-gel films. Effort was made to fabricate a PDA-modified sol-gel coating and a systematic investigation was conducted thereof. Long-term corrosion performance of this coating in 3.5 wt.% NaCl solution was evaluated through electrochemical impedance spectroscopy (EIS). Results show that the low-frequency impedance of the PDA-modified sol-gel coating remains significantly high at 7.9 × 10<sup>5</sup> Ω·cm<sup>2</sup>, even after 36 d of immersion in 3.5 wt.% NaCl medium, indicative of excellent protective properties. It notably surpasses low-frequency impedance of the unmodified coating, which registers at 2.5 × 10<sup>4</sup> Ω·cm<sup>2</sup>. The incorporation of PDA into the sol-gel coating, facilitated by adsorption and diffusion mechanisms, serves to fill micrometer- and nanometer-scale defects of the coating, thereby markedly enhancing their compactness. Furthermore, despite its modest thickness of 9 μm, the PDA-modified coating exhibits enduring corrosion protection capabilities.</div></div>","PeriodicalId":100337,"journal":{"name":"Corrosion Communications","volume":"17 ","pages":"Pages 57-65"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PDA-modified sol-gel coating for long-lasting corrosion protection on Al alloy 3003\",\"authors\":\"Zhiyuan Feng , Jiao Li , Keqi Huang , Guoqiang Liu , Huanhuan Bai , Xin Huang , Jun Qi , Zhengwei Tang , Penghai Xu , Xiaofei Yang , Zheng Qu , Guozhe Meng\",\"doi\":\"10.1016/j.corcom.2023.11.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Within the realm of corrosion protection methods for Al alloys, sol-gel technique has garnered increasing attention. However, conventional sol-gel methodologies cannot provide adequate long-lasting corrosion protection to Al alloys when exposed to chloride-rich solutions. This paper introduces an innovative approach to substantially augment the corrosion resistance of aluminum alloys through utilization of polydopamine (PDA)-modified sol-gel films. Effort was made to fabricate a PDA-modified sol-gel coating and a systematic investigation was conducted thereof. Long-term corrosion performance of this coating in 3.5 wt.% NaCl solution was evaluated through electrochemical impedance spectroscopy (EIS). Results show that the low-frequency impedance of the PDA-modified sol-gel coating remains significantly high at 7.9 × 10<sup>5</sup> Ω·cm<sup>2</sup>, even after 36 d of immersion in 3.5 wt.% NaCl medium, indicative of excellent protective properties. It notably surpasses low-frequency impedance of the unmodified coating, which registers at 2.5 × 10<sup>4</sup> Ω·cm<sup>2</sup>. The incorporation of PDA into the sol-gel coating, facilitated by adsorption and diffusion mechanisms, serves to fill micrometer- and nanometer-scale defects of the coating, thereby markedly enhancing their compactness. Furthermore, despite its modest thickness of 9 μm, the PDA-modified coating exhibits enduring corrosion protection capabilities.</div></div>\",\"PeriodicalId\":100337,\"journal\":{\"name\":\"Corrosion Communications\",\"volume\":\"17 \",\"pages\":\"Pages 57-65\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Corrosion Communications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667266924000562\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion Communications","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667266924000562","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
PDA-modified sol-gel coating for long-lasting corrosion protection on Al alloy 3003
Within the realm of corrosion protection methods for Al alloys, sol-gel technique has garnered increasing attention. However, conventional sol-gel methodologies cannot provide adequate long-lasting corrosion protection to Al alloys when exposed to chloride-rich solutions. This paper introduces an innovative approach to substantially augment the corrosion resistance of aluminum alloys through utilization of polydopamine (PDA)-modified sol-gel films. Effort was made to fabricate a PDA-modified sol-gel coating and a systematic investigation was conducted thereof. Long-term corrosion performance of this coating in 3.5 wt.% NaCl solution was evaluated through electrochemical impedance spectroscopy (EIS). Results show that the low-frequency impedance of the PDA-modified sol-gel coating remains significantly high at 7.9 × 105 Ω·cm2, even after 36 d of immersion in 3.5 wt.% NaCl medium, indicative of excellent protective properties. It notably surpasses low-frequency impedance of the unmodified coating, which registers at 2.5 × 104 Ω·cm2. The incorporation of PDA into the sol-gel coating, facilitated by adsorption and diffusion mechanisms, serves to fill micrometer- and nanometer-scale defects of the coating, thereby markedly enhancing their compactness. Furthermore, despite its modest thickness of 9 μm, the PDA-modified coating exhibits enduring corrosion protection capabilities.