{"title":"超声横波弹性成像中t形传感器测定肌纤维方向的校正方法","authors":"Chien Chen;Guo-Xuan Xu;Wei-Ren Su;Chih-Chung Huang","doi":"10.1109/TMI.2025.3541321","DOIUrl":null,"url":null,"abstract":"Shear wave elastography (SWE) is a quantitative imaging method that could be used for clinical assessment of musculoskeletal stiffness, particularly in disease diagnosis and rehabilitation evaluation. However, the elastic anisotropy of skeletal muscle leads to uncertainties in shear wave velocity (SWV) measurements in SWE because the SWV varies with muscle fiber orientation. Therefore, many studies have conducted 360° rotational measurements of SWV to determine the elastic anisotropy of muscle; however, the extended data acquisition time of this approach limits its clinical utility. In this study, a T-shaped transducer was used for rapidly measuring the longitudinal and transverse SWVs (<inline-formula> <tex-math>$\\textit {SWV}_{L}$ </tex-math></inline-formula> and <inline-formula> <tex-math>$\\textit {SWV}_{T}$ </tex-math></inline-formula>) of muscle through an ellipse fitting method to estimate the fiber orientation angle when the excitation is normal to the material axis. The performance of this approach was examined by conducting a homogeneous elastic phantom experiment, which indicated that the proposed T-shaped transducer generated shear waves in three directions by applying a supersonic push at the junction of the transducer. The error between the measured SWVs and ground truth was approximately 6.5%. The proposed T-shaped transducer was also used to measure the SWV in the biceps brachii of four healthy individuals. The <inline-formula> <tex-math>$\\textit {SWV}_{L}$ </tex-math></inline-formula> and <inline-formula> <tex-math>$\\textit {SWV}_{T}$ </tex-math></inline-formula> values measured with this transducer were 2.47 and 1.09 m/s, respectively, which were consistent with the SWVs obtained under 360° rotation and in the literature (an error of ~4%). All experimental results were consistent with the results obtained under 360° rotation, which indicates that the proposed method enables the rapid and stable estimation of muscle fiber orientation in SWE.","PeriodicalId":94033,"journal":{"name":"IEEE transactions on medical imaging","volume":"44 6","pages":"2528-2540"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Method for Correcting the Muscle Fiber Orientation Determined by a T-Shaped Transducer in Ultrasound Shear Wave Elastography\",\"authors\":\"Chien Chen;Guo-Xuan Xu;Wei-Ren Su;Chih-Chung Huang\",\"doi\":\"10.1109/TMI.2025.3541321\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Shear wave elastography (SWE) is a quantitative imaging method that could be used for clinical assessment of musculoskeletal stiffness, particularly in disease diagnosis and rehabilitation evaluation. However, the elastic anisotropy of skeletal muscle leads to uncertainties in shear wave velocity (SWV) measurements in SWE because the SWV varies with muscle fiber orientation. Therefore, many studies have conducted 360° rotational measurements of SWV to determine the elastic anisotropy of muscle; however, the extended data acquisition time of this approach limits its clinical utility. In this study, a T-shaped transducer was used for rapidly measuring the longitudinal and transverse SWVs (<inline-formula> <tex-math>$\\\\textit {SWV}_{L}$ </tex-math></inline-formula> and <inline-formula> <tex-math>$\\\\textit {SWV}_{T}$ </tex-math></inline-formula>) of muscle through an ellipse fitting method to estimate the fiber orientation angle when the excitation is normal to the material axis. The performance of this approach was examined by conducting a homogeneous elastic phantom experiment, which indicated that the proposed T-shaped transducer generated shear waves in three directions by applying a supersonic push at the junction of the transducer. The error between the measured SWVs and ground truth was approximately 6.5%. The proposed T-shaped transducer was also used to measure the SWV in the biceps brachii of four healthy individuals. The <inline-formula> <tex-math>$\\\\textit {SWV}_{L}$ </tex-math></inline-formula> and <inline-formula> <tex-math>$\\\\textit {SWV}_{T}$ </tex-math></inline-formula> values measured with this transducer were 2.47 and 1.09 m/s, respectively, which were consistent with the SWVs obtained under 360° rotation and in the literature (an error of ~4%). All experimental results were consistent with the results obtained under 360° rotation, which indicates that the proposed method enables the rapid and stable estimation of muscle fiber orientation in SWE.\",\"PeriodicalId\":94033,\"journal\":{\"name\":\"IEEE transactions on medical imaging\",\"volume\":\"44 6\",\"pages\":\"2528-2540\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on medical imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10884595/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical imaging","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10884595/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

横波弹性成像(SWE)是一种定量成像方法,可用于临床评估肌肉骨骼刚度,特别是疾病诊断和康复评估。然而,骨骼肌的弹性各向异性导致了横波速度(SWV)测量的不确定性,因为横波速度随肌纤维方向的变化而变化。因此,许多研究对SWV进行了360°旋转测量,以确定肌肉的弹性各向异性;然而,该方法的数据采集时间较长,限制了其临床应用。在本研究中,使用T形传感器,通过椭圆拟合方法快速测量肌肉的纵向和横向SWV ($\textit {SWV}_{L}$和$\textit {SWV}_{T}$),以估计当激励垂直于材料轴时纤维的取向角。通过进行均匀弹性模体实验来检验该方法的性能,结果表明,所提出的t形换能器通过在换能器的交界处施加超音速推力,在三个方向上产生剪切波。测量的swv与地面真实值之间的误差约为6.5%。所提出的t形换能器也被用于测量四个健康个体的肱二头肌的SWV。该传感器测得的$\textit {SWV}_{L}$和$\textit {SWV}_{T}$的值分别为2.47和1.09 m/s,与文献中360°旋转下得到的SWV值一致(误差约为4%)。所有实验结果与360°旋转下的结果一致,表明该方法能够快速、稳定地估计SWE中肌纤维的方向。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Method for Correcting the Muscle Fiber Orientation Determined by a T-Shaped Transducer in Ultrasound Shear Wave Elastography
Shear wave elastography (SWE) is a quantitative imaging method that could be used for clinical assessment of musculoskeletal stiffness, particularly in disease diagnosis and rehabilitation evaluation. However, the elastic anisotropy of skeletal muscle leads to uncertainties in shear wave velocity (SWV) measurements in SWE because the SWV varies with muscle fiber orientation. Therefore, many studies have conducted 360° rotational measurements of SWV to determine the elastic anisotropy of muscle; however, the extended data acquisition time of this approach limits its clinical utility. In this study, a T-shaped transducer was used for rapidly measuring the longitudinal and transverse SWVs ( $\textit {SWV}_{L}$ and $\textit {SWV}_{T}$ ) of muscle through an ellipse fitting method to estimate the fiber orientation angle when the excitation is normal to the material axis. The performance of this approach was examined by conducting a homogeneous elastic phantom experiment, which indicated that the proposed T-shaped transducer generated shear waves in three directions by applying a supersonic push at the junction of the transducer. The error between the measured SWVs and ground truth was approximately 6.5%. The proposed T-shaped transducer was also used to measure the SWV in the biceps brachii of four healthy individuals. The $\textit {SWV}_{L}$ and $\textit {SWV}_{T}$ values measured with this transducer were 2.47 and 1.09 m/s, respectively, which were consistent with the SWVs obtained under 360° rotation and in the literature (an error of ~4%). All experimental results were consistent with the results obtained under 360° rotation, which indicates that the proposed method enables the rapid and stable estimation of muscle fiber orientation in SWE.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信