通过LMA保护器和i-gel在成人瘫痪患者中纤维引导气管插管的比较-一项随机对照研究。

IF 2.9 Q1 ANESTHESIOLOGY
Indian Journal of Anaesthesia Pub Date : 2024-12-01 Epub Date: 2024-12-03 DOI:10.4103/ija.ija_656_24
Mamta Bhardwaj, Karthik Manoharan, Kirti Kshetrapal, Karishma Dhankhar, Amit Singh, Susheela Taxak
{"title":"通过LMA保护器和i-gel在成人瘫痪患者中纤维引导气管插管的比较-一项随机对照研究。","authors":"Mamta Bhardwaj, Karthik Manoharan, Kirti Kshetrapal, Karishma Dhankhar, Amit Singh, Susheela Taxak","doi":"10.4103/ija.ija_656_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Second-generation supraglottic airway devices (SADs) are used for ventilation and a conduit for fibreoptic-guided tracheal intubation (FGI). LMA Protector is a novel second-generation SAD with a wide airway lumen to pass an adequately sized tracheal tube. Few authors have compared LMA Protector with i-gel for FGI using reinforced tubes, and their results have been contradictory. Polyvinyl chloride (PVC) endotracheal tube (ETT) is the most commonly used ETT in the operation theatre and critical care units. Hence, we conducted this study to compare FGI through i-gel and LMA Protector using PVC ETT.</p><p><strong>Methods: </strong>After institutional committee approval and trial registration, 66 patients aged 18-70 years with American Society of Anesthesiologists physical status I/II were recruited for this randomised study. Patients were randomly allocated to groups LP and IG. The primary outcome was to compare time to tracheal intubation via two SADs. Insertion characteristics such as the number of insertion attempts, mean time of insertion, oropharyngeal leak pressure, and intubation characteristics (time to view carina, number of attempts, etc.) were considered secondary outcomes. Independent Student's <i>t</i>-test and Mann-Whitney U test were applied for normally distributed and non-normally distributed quantitative variables, respectively.</p><p><strong>Results: </strong>Demographic parameters were comparable in the two groups (<i>P</i> > 0.05). The time to view the carina, tracheal intubation time, other insertion characteristics, and adverse effects were comparable between the groups (<i>P</i> > 0.05).</p><p><strong>Conclusion: </strong>LMA Protector and i-gel are technically comparable conduits for fibreoptic-guided tracheal intubation in adult paralysed patients.</p>","PeriodicalId":13339,"journal":{"name":"Indian Journal of Anaesthesia","volume":"68 12","pages":"1049-1054"},"PeriodicalIF":2.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11812508/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of fibreoptic-guided tracheal intubation through LMA Protector and i-gel in adult paralysed patients - A randomised comparative study.\",\"authors\":\"Mamta Bhardwaj, Karthik Manoharan, Kirti Kshetrapal, Karishma Dhankhar, Amit Singh, Susheela Taxak\",\"doi\":\"10.4103/ija.ija_656_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and aims: </strong>Second-generation supraglottic airway devices (SADs) are used for ventilation and a conduit for fibreoptic-guided tracheal intubation (FGI). LMA Protector is a novel second-generation SAD with a wide airway lumen to pass an adequately sized tracheal tube. Few authors have compared LMA Protector with i-gel for FGI using reinforced tubes, and their results have been contradictory. Polyvinyl chloride (PVC) endotracheal tube (ETT) is the most commonly used ETT in the operation theatre and critical care units. Hence, we conducted this study to compare FGI through i-gel and LMA Protector using PVC ETT.</p><p><strong>Methods: </strong>After institutional committee approval and trial registration, 66 patients aged 18-70 years with American Society of Anesthesiologists physical status I/II were recruited for this randomised study. Patients were randomly allocated to groups LP and IG. The primary outcome was to compare time to tracheal intubation via two SADs. Insertion characteristics such as the number of insertion attempts, mean time of insertion, oropharyngeal leak pressure, and intubation characteristics (time to view carina, number of attempts, etc.) were considered secondary outcomes. Independent Student's <i>t</i>-test and Mann-Whitney U test were applied for normally distributed and non-normally distributed quantitative variables, respectively.</p><p><strong>Results: </strong>Demographic parameters were comparable in the two groups (<i>P</i> > 0.05). The time to view the carina, tracheal intubation time, other insertion characteristics, and adverse effects were comparable between the groups (<i>P</i> > 0.05).</p><p><strong>Conclusion: </strong>LMA Protector and i-gel are technically comparable conduits for fibreoptic-guided tracheal intubation in adult paralysed patients.</p>\",\"PeriodicalId\":13339,\"journal\":{\"name\":\"Indian Journal of Anaesthesia\",\"volume\":\"68 12\",\"pages\":\"1049-1054\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11812508/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Anaesthesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ija.ija_656_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Anaesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ija.ija_656_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:第二代声门上气道装置(SADs)用于通气和纤维引导气管插管(FGI)的导管。LMA保护器是一种新型的第二代SAD,具有宽气道管腔以通过适当大小的气管管。很少有作者将LMA保护剂与i-gel用于增强管的FGI进行比较,其结果相互矛盾。聚氯乙烯(PVC)气管内管是手术室和重症监护病房最常用的气管内管。因此,我们进行了这项研究,比较了通过i-gel和使用PVC ETT的LMA保护器的FGI。方法:经机构委员会批准和试验注册后,66例年龄18-70岁,美国麻醉医师学会身体状态为I/II的患者被纳入本随机研究。患者随机分为LP组和IG组。主要结果是比较通过两个SADs进行气管插管的时间。插入特征,如插入次数、平均插入时间、口咽漏压和插管特征(观察隆突的时间、尝试次数等)被认为是次要结局。正态分布和非正态分布的定量变量分别采用独立学生t检验和Mann-Whitney U检验。结果:两组患者人口学参数具有可比性(P < 0.05)。两组间观察隆突时间、气管插管时间、其他插入特征及不良反应具有可比性(P < 0.05)。结论:LMA保护器和i-gel在成人瘫痪患者的纤维引导气管插管中具有技术可比性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of fibreoptic-guided tracheal intubation through LMA Protector and i-gel in adult paralysed patients - A randomised comparative study.

Background and aims: Second-generation supraglottic airway devices (SADs) are used for ventilation and a conduit for fibreoptic-guided tracheal intubation (FGI). LMA Protector is a novel second-generation SAD with a wide airway lumen to pass an adequately sized tracheal tube. Few authors have compared LMA Protector with i-gel for FGI using reinforced tubes, and their results have been contradictory. Polyvinyl chloride (PVC) endotracheal tube (ETT) is the most commonly used ETT in the operation theatre and critical care units. Hence, we conducted this study to compare FGI through i-gel and LMA Protector using PVC ETT.

Methods: After institutional committee approval and trial registration, 66 patients aged 18-70 years with American Society of Anesthesiologists physical status I/II were recruited for this randomised study. Patients were randomly allocated to groups LP and IG. The primary outcome was to compare time to tracheal intubation via two SADs. Insertion characteristics such as the number of insertion attempts, mean time of insertion, oropharyngeal leak pressure, and intubation characteristics (time to view carina, number of attempts, etc.) were considered secondary outcomes. Independent Student's t-test and Mann-Whitney U test were applied for normally distributed and non-normally distributed quantitative variables, respectively.

Results: Demographic parameters were comparable in the two groups (P > 0.05). The time to view the carina, tracheal intubation time, other insertion characteristics, and adverse effects were comparable between the groups (P > 0.05).

Conclusion: LMA Protector and i-gel are technically comparable conduits for fibreoptic-guided tracheal intubation in adult paralysed patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.20
自引率
44.80%
发文量
210
审稿时长
36 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信