可穿戴设备在围手术期的应用。

IF 2.3 3区 医学 Q2 ANESTHESIOLOGY
Current Opinion in Anesthesiology Pub Date : 2025-04-01 Epub Date: 2025-02-13 DOI:10.1097/ACO.0000000000001473
Alexander J Xiang, Jenny Xinye Hu, Karim S Ladha
{"title":"可穿戴设备在围手术期的应用。","authors":"Alexander J Xiang, Jenny Xinye Hu, Karim S Ladha","doi":"10.1097/ACO.0000000000001473","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>Improved perioperative patient monitoring is a crucial step toward better predicting postoperative outcomes. Wearable devices capable of measuring various health-related metrics represent a novel tool that can assist healthcare providers. However, the literature surrounding wearables is wide-ranging, preventing clinicians from drawing definitive conclusions regarding their utility. This review intends to consolidate the recent literature on perioperative wearables and summarize the most salient information.</p><p><strong>Recent findings: </strong>Wearable devices measuring cardiac output and colonic motility have recently been piloted with mixed results. Novel measurement techniques for established metrics have also been studied, including photoplethysmography devices for heart rate and blood pressure along with resistance thermometers for temperature. Nuanced methods of synthesizing data have been piloted, including machine-learning algorithms for predicting adverse events and trajectory curves for step count progression. Wearable devices are generally well accepted, although adjuvant support systems have improved patient satisfaction.</p><p><strong>Summary: </strong>Perioperative wearables are valuable tools for tracking postoperative health metrics, predicting adverse events, and improving patient satisfaction. Future research on removing barriers such as technological illiteracy, artifact generation, and false-positive alarms would enable better integration of wearables into the hospital setting.</p>","PeriodicalId":50609,"journal":{"name":"Current Opinion in Anesthesiology","volume":" ","pages":"143-150"},"PeriodicalIF":2.3000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The utility of wearable devices in the perioperative period.\",\"authors\":\"Alexander J Xiang, Jenny Xinye Hu, Karim S Ladha\",\"doi\":\"10.1097/ACO.0000000000001473\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose of review: </strong>Improved perioperative patient monitoring is a crucial step toward better predicting postoperative outcomes. Wearable devices capable of measuring various health-related metrics represent a novel tool that can assist healthcare providers. However, the literature surrounding wearables is wide-ranging, preventing clinicians from drawing definitive conclusions regarding their utility. This review intends to consolidate the recent literature on perioperative wearables and summarize the most salient information.</p><p><strong>Recent findings: </strong>Wearable devices measuring cardiac output and colonic motility have recently been piloted with mixed results. Novel measurement techniques for established metrics have also been studied, including photoplethysmography devices for heart rate and blood pressure along with resistance thermometers for temperature. Nuanced methods of synthesizing data have been piloted, including machine-learning algorithms for predicting adverse events and trajectory curves for step count progression. Wearable devices are generally well accepted, although adjuvant support systems have improved patient satisfaction.</p><p><strong>Summary: </strong>Perioperative wearables are valuable tools for tracking postoperative health metrics, predicting adverse events, and improving patient satisfaction. Future research on removing barriers such as technological illiteracy, artifact generation, and false-positive alarms would enable better integration of wearables into the hospital setting.</p>\",\"PeriodicalId\":50609,\"journal\":{\"name\":\"Current Opinion in Anesthesiology\",\"volume\":\" \",\"pages\":\"143-150\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Opinion in Anesthesiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ACO.0000000000001473\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Opinion in Anesthesiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ACO.0000000000001473","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/13 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

综述目的:改善围手术期患者监测是更好地预测术后预后的关键一步。能够测量各种健康相关指标的可穿戴设备代表了一种可以帮助医疗保健提供者的新工具。然而,关于可穿戴设备的文献非常广泛,这使得临床医生无法就其实用性得出明确的结论。本综述旨在整合最近关于围手术期可穿戴设备的文献,并总结最重要的信息。最近的发现:测量心输出量和结肠运动的可穿戴设备最近已经试用,结果好坏参半。对于已建立的度量的新测量技术也进行了研究,包括用于心率和血压的光电容积脉搏仪设备以及用于温度的电阻温度计。精细的数据合成方法已经试行,包括预测不良事件的机器学习算法和步数进展的轨迹曲线。可穿戴设备普遍被接受,尽管辅助支持系统提高了患者的满意度。总结:围手术期可穿戴设备是追踪术后健康指标、预测不良事件和提高患者满意度的宝贵工具。未来关于消除技术文盲、人工制品产生和误报警报等障碍的研究将使可穿戴设备更好地融入医院环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The utility of wearable devices in the perioperative period.

Purpose of review: Improved perioperative patient monitoring is a crucial step toward better predicting postoperative outcomes. Wearable devices capable of measuring various health-related metrics represent a novel tool that can assist healthcare providers. However, the literature surrounding wearables is wide-ranging, preventing clinicians from drawing definitive conclusions regarding their utility. This review intends to consolidate the recent literature on perioperative wearables and summarize the most salient information.

Recent findings: Wearable devices measuring cardiac output and colonic motility have recently been piloted with mixed results. Novel measurement techniques for established metrics have also been studied, including photoplethysmography devices for heart rate and blood pressure along with resistance thermometers for temperature. Nuanced methods of synthesizing data have been piloted, including machine-learning algorithms for predicting adverse events and trajectory curves for step count progression. Wearable devices are generally well accepted, although adjuvant support systems have improved patient satisfaction.

Summary: Perioperative wearables are valuable tools for tracking postoperative health metrics, predicting adverse events, and improving patient satisfaction. Future research on removing barriers such as technological illiteracy, artifact generation, and false-positive alarms would enable better integration of wearables into the hospital setting.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.90
自引率
8.00%
发文量
207
审稿时长
12 months
期刊介绍: ​​​​​​​​Published bimonthly and offering a unique and wide ranging perspective on the key developments in the field, each issue of Current Opinion in Anesthesiology features hand-picked review articles from our team of expert editors. With fifteen disciplines published across the year – including cardiovascular anesthesiology, neuroanesthesia and pain medicine – every issue also contains annotated references detailing the merits of the most important papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信