经胸超声心动图随访对获得终末期肝病模型 (MELD) 豁免的重度肺动脉高压 (POPH) 患者的筛查作用。

IF 1.9 Q3 TRANSPLANTATION
Transplantation Direct Pub Date : 2025-02-07 eCollection Date: 2025-03-01 DOI:10.1097/TXD.0000000000001757
Kathryn T Del Valle, Dana Kay, Michael J Krowka, James R Runo, Corey Sadd, Julie K Heimbach, Rodrigo Cartin-Ceba, Hector R Cajigas, Charles D Burger, John E Moss, Hilary M DuBrock
{"title":"经胸超声心动图随访对获得终末期肝病模型 (MELD) 豁免的重度肺动脉高压 (POPH) 患者的筛查作用。","authors":"Kathryn T Del Valle, Dana Kay, Michael J Krowka, James R Runo, Corey Sadd, Julie K Heimbach, Rodrigo Cartin-Ceba, Hector R Cajigas, Charles D Burger, John E Moss, Hilary M DuBrock","doi":"10.1097/TXD.0000000000001757","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The current model for end-stage liver disease (MELD) exception policies for portopulmonary hypertension (POPH) require serial right heart catheterizations (RHCs) every 3 mo to maintain exception points. RHC is necessary for the initial diagnosis of POPH, but the utility of serial catheterizations has not been studied. In patients with POPH MELD exceptions, we sought to compare noninvasive and invasive hemodynamics and determine the sensitivity of echocardiography for the detection of hemodynamically severe POPH that would preclude liver transplant.</p><p><strong>Methods: </strong>We performed a single-center retrospective cohort study of patients with POPH MELD exceptions who underwent liver transplant from December 2008 to January 2024. Results were validated at an external center. Echocardiograms and RHCs performed within 1 mo were compared. Pearson correlation coefficient and Bland-Altman plots assessed the association between echocardiogram and RHC variables. We examined varied echocardiographic parameters to optimize sensitivity for the detection of hemodynamically severe POPH.</p><p><strong>Results: </strong>Twenty-two individuals underwent 60 follow-up RHCs with paired echocardiograms. Right ventricular systolic pressure (RVSP) and cardiac index estimated with echocardiogram were not strongly correlated with RHC measurements at follow-up (RVSP and RHC pulmonary artery systolic pressure: <i>R</i> = 0.30, <i>P</i> = 0.02; cardiac index: <i>R</i> = 0.17, <i>P</i> = 0.21). However, echocardiograms with RVSP ≥48 mm Hg had 100% sensitivity for detecting hemodynamically severe POPH, with 100% negative predictive value. In external validation of 13 paired echocardiograms and RHCs, our algorithm had 64% specificity and 100% negative predictive value.</p><p><strong>Conclusions: </strong>Although echocardiogram and RHC hemodynamic estimates were not strongly correlated, these results could potentially negate the current requirement for repeat RHC every 3 mo to maintain POPH MELD exception.</p>","PeriodicalId":23225,"journal":{"name":"Transplantation Direct","volume":"11 3","pages":"e1757"},"PeriodicalIF":1.9000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11810002/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Utility of Follow-up Transthoracic Echocardiogram to Screen for Severe Portopulmonary Hypertension (POPH) in Patients Granted POPH Model for End-stage Liver Disease (MELD) Exceptions.\",\"authors\":\"Kathryn T Del Valle, Dana Kay, Michael J Krowka, James R Runo, Corey Sadd, Julie K Heimbach, Rodrigo Cartin-Ceba, Hector R Cajigas, Charles D Burger, John E Moss, Hilary M DuBrock\",\"doi\":\"10.1097/TXD.0000000000001757\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The current model for end-stage liver disease (MELD) exception policies for portopulmonary hypertension (POPH) require serial right heart catheterizations (RHCs) every 3 mo to maintain exception points. RHC is necessary for the initial diagnosis of POPH, but the utility of serial catheterizations has not been studied. In patients with POPH MELD exceptions, we sought to compare noninvasive and invasive hemodynamics and determine the sensitivity of echocardiography for the detection of hemodynamically severe POPH that would preclude liver transplant.</p><p><strong>Methods: </strong>We performed a single-center retrospective cohort study of patients with POPH MELD exceptions who underwent liver transplant from December 2008 to January 2024. Results were validated at an external center. Echocardiograms and RHCs performed within 1 mo were compared. Pearson correlation coefficient and Bland-Altman plots assessed the association between echocardiogram and RHC variables. We examined varied echocardiographic parameters to optimize sensitivity for the detection of hemodynamically severe POPH.</p><p><strong>Results: </strong>Twenty-two individuals underwent 60 follow-up RHCs with paired echocardiograms. Right ventricular systolic pressure (RVSP) and cardiac index estimated with echocardiogram were not strongly correlated with RHC measurements at follow-up (RVSP and RHC pulmonary artery systolic pressure: <i>R</i> = 0.30, <i>P</i> = 0.02; cardiac index: <i>R</i> = 0.17, <i>P</i> = 0.21). However, echocardiograms with RVSP ≥48 mm Hg had 100% sensitivity for detecting hemodynamically severe POPH, with 100% negative predictive value. In external validation of 13 paired echocardiograms and RHCs, our algorithm had 64% specificity and 100% negative predictive value.</p><p><strong>Conclusions: </strong>Although echocardiogram and RHC hemodynamic estimates were not strongly correlated, these results could potentially negate the current requirement for repeat RHC every 3 mo to maintain POPH MELD exception.</p>\",\"PeriodicalId\":23225,\"journal\":{\"name\":\"Transplantation Direct\",\"volume\":\"11 3\",\"pages\":\"e1757\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-02-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11810002/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transplantation Direct\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/TXD.0000000000001757\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"TRANSPLANTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transplantation Direct","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/TXD.0000000000001757","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"TRANSPLANTATION","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Utility of Follow-up Transthoracic Echocardiogram to Screen for Severe Portopulmonary Hypertension (POPH) in Patients Granted POPH Model for End-stage Liver Disease (MELD) Exceptions.

Background: The current model for end-stage liver disease (MELD) exception policies for portopulmonary hypertension (POPH) require serial right heart catheterizations (RHCs) every 3 mo to maintain exception points. RHC is necessary for the initial diagnosis of POPH, but the utility of serial catheterizations has not been studied. In patients with POPH MELD exceptions, we sought to compare noninvasive and invasive hemodynamics and determine the sensitivity of echocardiography for the detection of hemodynamically severe POPH that would preclude liver transplant.

Methods: We performed a single-center retrospective cohort study of patients with POPH MELD exceptions who underwent liver transplant from December 2008 to January 2024. Results were validated at an external center. Echocardiograms and RHCs performed within 1 mo were compared. Pearson correlation coefficient and Bland-Altman plots assessed the association between echocardiogram and RHC variables. We examined varied echocardiographic parameters to optimize sensitivity for the detection of hemodynamically severe POPH.

Results: Twenty-two individuals underwent 60 follow-up RHCs with paired echocardiograms. Right ventricular systolic pressure (RVSP) and cardiac index estimated with echocardiogram were not strongly correlated with RHC measurements at follow-up (RVSP and RHC pulmonary artery systolic pressure: R = 0.30, P = 0.02; cardiac index: R = 0.17, P = 0.21). However, echocardiograms with RVSP ≥48 mm Hg had 100% sensitivity for detecting hemodynamically severe POPH, with 100% negative predictive value. In external validation of 13 paired echocardiograms and RHCs, our algorithm had 64% specificity and 100% negative predictive value.

Conclusions: Although echocardiogram and RHC hemodynamic estimates were not strongly correlated, these results could potentially negate the current requirement for repeat RHC every 3 mo to maintain POPH MELD exception.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Transplantation Direct
Transplantation Direct TRANSPLANTATION-
CiteScore
3.40
自引率
4.30%
发文量
193
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信