{"title":"影像引导过程中介入医师PNS安全性的初步评估。","authors":"Feng Jia, Axel Vom Endt, Philipp Amrein, Maximilian Frederik Russe, Heiko Rohdjess, Martino Leghissa, Maxim Zaitsev, Sebastian Littin","doi":"10.1007/s10334-025-01228-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study investigates peripheral nerve stimulation (PNS) safety thresholds for health professionals performing MRI procedures and the variation of arm rotations in close vicinity to the magnet bore.</p><p><strong>Methods: </strong>Employing two posable human body models, this research utilized quasi-static electromagnetic calculations and neurodynamic simulations to assess PNS thresholds. Different arm rotations are compared for standing interventionalist's posture assuming the supine patient position, typical for medical interventions inside MRI devices.</p><p><strong>Results: </strong>This study reveals that arm rotations in standing postures result in variations in PNS thresholds. However, for all the arm poses considered, the threshold was at least 2.4 times higher compared to the patient position. Differences in PNS thresholds and electric field distributions were observed between male and female models.</p><p><strong>Conclusions: </strong>The findings suggest that when the PNS thresholds for imaging subjects are not exceeded, it is likely that a subject leaning into the bore will also not experience PNS. However, variations in PNS thresholds due to arm movements highlight the importance of considering body posture in MRI safety protocols.</p>","PeriodicalId":18067,"journal":{"name":"Magnetic Resonance Materials in Physics, Biology and Medicine","volume":" ","pages":"239-251"},"PeriodicalIF":2.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11914522/pdf/","citationCount":"0","resultStr":"{\"title\":\"Initial assessment of PNS safety for interventionalists during image-guided procedures.\",\"authors\":\"Feng Jia, Axel Vom Endt, Philipp Amrein, Maximilian Frederik Russe, Heiko Rohdjess, Martino Leghissa, Maxim Zaitsev, Sebastian Littin\",\"doi\":\"10.1007/s10334-025-01228-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study investigates peripheral nerve stimulation (PNS) safety thresholds for health professionals performing MRI procedures and the variation of arm rotations in close vicinity to the magnet bore.</p><p><strong>Methods: </strong>Employing two posable human body models, this research utilized quasi-static electromagnetic calculations and neurodynamic simulations to assess PNS thresholds. Different arm rotations are compared for standing interventionalist's posture assuming the supine patient position, typical for medical interventions inside MRI devices.</p><p><strong>Results: </strong>This study reveals that arm rotations in standing postures result in variations in PNS thresholds. However, for all the arm poses considered, the threshold was at least 2.4 times higher compared to the patient position. Differences in PNS thresholds and electric field distributions were observed between male and female models.</p><p><strong>Conclusions: </strong>The findings suggest that when the PNS thresholds for imaging subjects are not exceeded, it is likely that a subject leaning into the bore will also not experience PNS. However, variations in PNS thresholds due to arm movements highlight the importance of considering body posture in MRI safety protocols.</p>\",\"PeriodicalId\":18067,\"journal\":{\"name\":\"Magnetic Resonance Materials in Physics, Biology and Medicine\",\"volume\":\" \",\"pages\":\"239-251\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11914522/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance Materials in Physics, Biology and Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10334-025-01228-4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance Materials in Physics, Biology and Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10334-025-01228-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究探讨外周神经刺激(PNS)安全阈值的卫生专业人员执行MRI程序和变化的手臂旋转接近磁铁孔。方法:采用两种可能的人体模型,采用准静态电磁计算和神经动力学模拟评估PNS阈值。不同的手臂旋转比较站立的介入医生的姿势假设仰卧的病人位置,典型的医疗干预在MRI设备内。结果:本研究揭示了站立姿势的手臂旋转导致PNS阈值的变化。然而,对于所有考虑的手臂姿势,阈值至少比患者的姿势高2.4倍。观察男女模型PNS阈值和电场分布的差异。结论:研究结果表明,当不超过成像受试者的PNS阈值时,受试者很可能也不会经历PNS。然而,由于手臂运动引起的PNS阈值的变化强调了在MRI安全方案中考虑身体姿势的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Initial assessment of PNS safety for interventionalists during image-guided procedures.

Purpose: This study investigates peripheral nerve stimulation (PNS) safety thresholds for health professionals performing MRI procedures and the variation of arm rotations in close vicinity to the magnet bore.

Methods: Employing two posable human body models, this research utilized quasi-static electromagnetic calculations and neurodynamic simulations to assess PNS thresholds. Different arm rotations are compared for standing interventionalist's posture assuming the supine patient position, typical for medical interventions inside MRI devices.

Results: This study reveals that arm rotations in standing postures result in variations in PNS thresholds. However, for all the arm poses considered, the threshold was at least 2.4 times higher compared to the patient position. Differences in PNS thresholds and electric field distributions were observed between male and female models.

Conclusions: The findings suggest that when the PNS thresholds for imaging subjects are not exceeded, it is likely that a subject leaning into the bore will also not experience PNS. However, variations in PNS thresholds due to arm movements highlight the importance of considering body posture in MRI safety protocols.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.60
自引率
0.00%
发文量
58
审稿时长
>12 weeks
期刊介绍: MAGMA is a multidisciplinary international journal devoted to the publication of articles on all aspects of magnetic resonance techniques and their applications in medicine and biology. MAGMA currently publishes research papers, reviews, letters to the editor, and commentaries, six times a year. The subject areas covered by MAGMA include: advances in materials, hardware and software in magnetic resonance technology, new developments and results in research and practical applications of magnetic resonance imaging and spectroscopy related to biology and medicine, study of animal models and intact cells using magnetic resonance, reports of clinical trials on humans and clinical validation of magnetic resonance protocols.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信