减少燃烧系统中一氧化氮化学发光测量中的干扰效应。

R J Tidona, A A Nizami, N P Cernansky
{"title":"减少燃烧系统中一氧化氮化学发光测量中的干扰效应。","authors":"R J Tidona, A A Nizami, N P Cernansky","doi":"10.1080/08940630.1988.10466421","DOIUrl":null,"url":null,"abstract":"Experiments were carried out to determine the relative chemiluminescence quenching efficiencies as a function of third body concentration for each of the common combustion products, H/sub 2/O, CO/sub 2/, CO, H/sub 2/, O/sub 2/ and Ar. These results are compared with those or other investigators. The effect of reaction chamber pressure on analyzer response and the development of an analyzer design which incorporates an adjustable sample capillary inlet capable of maintaining a constant molar flow rate of sample gas to the reaction chamber are discussed. The effect of carbon monoxide interference on chemiluminescent NO/sub x/ measurement has been isolated and found to be significant. A means of correcting NO/sub x/ measurements for these CO interference effects is described. Quantification of NO and NO/sub 2/ absorption in liquid water in NO/sub x/ sampling systems has been made. Recommendations for sample system designs to handle the presence of water in the sample gas are made.","PeriodicalId":77731,"journal":{"name":"JAPCA","volume":"38 6","pages":"806-11"},"PeriodicalIF":0.0000,"publicationDate":"1988-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/08940630.1988.10466421","citationCount":"28","resultStr":"{\"title\":\"Reducing interference effects in the chemiluminescent measurement of nitric oxides from combustion systems.\",\"authors\":\"R J Tidona, A A Nizami, N P Cernansky\",\"doi\":\"10.1080/08940630.1988.10466421\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Experiments were carried out to determine the relative chemiluminescence quenching efficiencies as a function of third body concentration for each of the common combustion products, H/sub 2/O, CO/sub 2/, CO, H/sub 2/, O/sub 2/ and Ar. These results are compared with those or other investigators. The effect of reaction chamber pressure on analyzer response and the development of an analyzer design which incorporates an adjustable sample capillary inlet capable of maintaining a constant molar flow rate of sample gas to the reaction chamber are discussed. The effect of carbon monoxide interference on chemiluminescent NO/sub x/ measurement has been isolated and found to be significant. A means of correcting NO/sub x/ measurements for these CO interference effects is described. Quantification of NO and NO/sub 2/ absorption in liquid water in NO/sub x/ sampling systems has been made. Recommendations for sample system designs to handle the presence of water in the sample gas are made.\",\"PeriodicalId\":77731,\"journal\":{\"name\":\"JAPCA\",\"volume\":\"38 6\",\"pages\":\"806-11\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/08940630.1988.10466421\",\"citationCount\":\"28\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JAPCA\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/08940630.1988.10466421\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAPCA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08940630.1988.10466421","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 28

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reducing interference effects in the chemiluminescent measurement of nitric oxides from combustion systems.
Experiments were carried out to determine the relative chemiluminescence quenching efficiencies as a function of third body concentration for each of the common combustion products, H/sub 2/O, CO/sub 2/, CO, H/sub 2/, O/sub 2/ and Ar. These results are compared with those or other investigators. The effect of reaction chamber pressure on analyzer response and the development of an analyzer design which incorporates an adjustable sample capillary inlet capable of maintaining a constant molar flow rate of sample gas to the reaction chamber are discussed. The effect of carbon monoxide interference on chemiluminescent NO/sub x/ measurement has been isolated and found to be significant. A means of correcting NO/sub x/ measurements for these CO interference effects is described. Quantification of NO and NO/sub 2/ absorption in liquid water in NO/sub x/ sampling systems has been made. Recommendations for sample system designs to handle the presence of water in the sample gas are made.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信