一种基于同位素稀释-液相色谱-串联质谱的候选参考测量方法,用于定量人血清和血浆中的皮质醇。

IF 3.7 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY
Myriam Ott, Neeraj Singh, Friederike Bauland, Daniel Köppl, Kerstin Kandler, Alexander Gaudl, Andrea Geistanger, Uta Ceglarek, Manfred Rauh, Christian Geletneky, Judith Taibon
{"title":"一种基于同位素稀释-液相色谱-串联质谱的候选参考测量方法,用于定量人血清和血浆中的皮质醇。","authors":"Myriam Ott, Neeraj Singh, Friederike Bauland, Daniel Köppl, Kerstin Kandler, Alexander Gaudl, Andrea Geistanger, Uta Ceglarek, Manfred Rauh, Christian Geletneky, Judith Taibon","doi":"10.1515/cclm-2024-0879","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Accurate measurement of serum cortisol is crucial for the diagnosis and management of adrenal disorders. Thus, we have developed a novel isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC MS/MS)-based candidate reference measurement procedure (RMP) to quantify cortisol in human serum/plasma, offering higher sensitivity and reliability compared to existing RMPs.</p><p><strong>Methods: </strong>Quantitative Nuclear Magnetic Resonance spectroscopic (qNMR) methodology has been utilized to assign the absolute content (g/g) and SI-traceability to the reference materials. A novel two-dimensional heart-cut liquid chromatography (LC) approach was implemented for the LC-MS/MS, combined with a supported liquid extraction (SLE) sample preparation protocol. A multi-day validation experiment assessed precision and accuracy. Reproducibility was assessed by comparing procedure results between two independent laboratories, and measurement uncertainty (MU) was evaluated in compliance with current guidelines.</p><p><strong>Results: </strong>The established RMP exhibited high sensitivity, with a quantification range of 0.800-600 ng/mL (2.21-1,655 nmol/L), exceeding the ranges of existing JCTLM-listed RMPs. Intermediate precision was ≤2.6 %, and repeatability ranged from 0.9 to 1.9 % across all concentration levels. The relative mean bias ranged from -1.3 to 1.4 % for all matrices and concentration levels. Measurement uncertainties (MU) for cortisol in single measurements were ≤2.8 % regardless of the concentration level and sample type. Using the certified International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference panel, the equivalence between the candidate RMP and the Joint Committee on Traceability in Laboratory Medicine (JCTLM) listed RMPs (NRMeth 57 and NRMeth 8) was assessed, revealing excellent agreement.</p><p><strong>Conclusions: </strong>This RMP allows for highly sensitive and reproducible determination of cortisol. The performance of the RMP facilitates the standardization of routine assays and ensures traceability in the measurement of individual patient samples.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of cortisol in human serum and plasma.\",\"authors\":\"Myriam Ott, Neeraj Singh, Friederike Bauland, Daniel Köppl, Kerstin Kandler, Alexander Gaudl, Andrea Geistanger, Uta Ceglarek, Manfred Rauh, Christian Geletneky, Judith Taibon\",\"doi\":\"10.1515/cclm-2024-0879\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Accurate measurement of serum cortisol is crucial for the diagnosis and management of adrenal disorders. Thus, we have developed a novel isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC MS/MS)-based candidate reference measurement procedure (RMP) to quantify cortisol in human serum/plasma, offering higher sensitivity and reliability compared to existing RMPs.</p><p><strong>Methods: </strong>Quantitative Nuclear Magnetic Resonance spectroscopic (qNMR) methodology has been utilized to assign the absolute content (g/g) and SI-traceability to the reference materials. A novel two-dimensional heart-cut liquid chromatography (LC) approach was implemented for the LC-MS/MS, combined with a supported liquid extraction (SLE) sample preparation protocol. A multi-day validation experiment assessed precision and accuracy. Reproducibility was assessed by comparing procedure results between two independent laboratories, and measurement uncertainty (MU) was evaluated in compliance with current guidelines.</p><p><strong>Results: </strong>The established RMP exhibited high sensitivity, with a quantification range of 0.800-600 ng/mL (2.21-1,655 nmol/L), exceeding the ranges of existing JCTLM-listed RMPs. Intermediate precision was ≤2.6 %, and repeatability ranged from 0.9 to 1.9 % across all concentration levels. The relative mean bias ranged from -1.3 to 1.4 % for all matrices and concentration levels. Measurement uncertainties (MU) for cortisol in single measurements were ≤2.8 % regardless of the concentration level and sample type. Using the certified International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference panel, the equivalence between the candidate RMP and the Joint Committee on Traceability in Laboratory Medicine (JCTLM) listed RMPs (NRMeth 57 and NRMeth 8) was assessed, revealing excellent agreement.</p><p><strong>Conclusions: </strong>This RMP allows for highly sensitive and reproducible determination of cortisol. The performance of the RMP facilitates the standardization of routine assays and ensures traceability in the measurement of individual patient samples.</p>\",\"PeriodicalId\":10390,\"journal\":{\"name\":\"Clinical chemistry and laboratory medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical chemistry and laboratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm-2024-0879\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2024-0879","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:血清皮质醇的准确测定对肾上腺疾病的诊断和治疗至关重要。因此,我们开发了一种新的基于同位素稀释-液相色谱-串联质谱(ID-LC MS/MS)的候选参考测量程序(RMP)来定量人血清/血浆中的皮质醇,与现有的RMP相比,它具有更高的灵敏度和可靠性。方法:采用定量核磁共振(qNMR)方法对标准物质进行绝对含量(g/g)和si溯源性测定。结合支撑液萃取(SLE)样品制备方案,建立了一种新的二维心脏切割液相色谱(LC)方法用于LC-MS/MS。通过多日验证实验评估了精密度和准确度。通过比较两个独立实验室之间的程序结果来评估再现性,并根据现行指南评估测量不确定度(MU)。结果:所建立的RMP具有较高的灵敏度,定量范围为0.800 ~ 600 ng/mL(2.21 ~ 1655 nmol/L),超过了现有jctlm所列RMP的测定范围。中间精密度≤2.6 %,所有浓度水平的重复性范围为0.9 ~ 1.9 %。所有基质和浓度水平的相对平均偏倚范围为-1.3至1.4 %。无论浓度水平和样品类型如何,单次测量皮质醇的测量不确定度(MU)≤2.8 %。使用经认证的国际临床化学和检验医学联合会(IFCC)参考小组,评估候选RMP与检验医学可追溯性联合委员会(JCTLM)列出的RMP (NRMeth 57和NRMeth 8)之间的等效性,显示非常一致。结论:该RMP允许高灵敏度和可重复性的皮质醇测定。RMP的性能促进了常规分析的标准化,并确保了个体患者样本测量的可追溯性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of cortisol in human serum and plasma.

Objectives: Accurate measurement of serum cortisol is crucial for the diagnosis and management of adrenal disorders. Thus, we have developed a novel isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC MS/MS)-based candidate reference measurement procedure (RMP) to quantify cortisol in human serum/plasma, offering higher sensitivity and reliability compared to existing RMPs.

Methods: Quantitative Nuclear Magnetic Resonance spectroscopic (qNMR) methodology has been utilized to assign the absolute content (g/g) and SI-traceability to the reference materials. A novel two-dimensional heart-cut liquid chromatography (LC) approach was implemented for the LC-MS/MS, combined with a supported liquid extraction (SLE) sample preparation protocol. A multi-day validation experiment assessed precision and accuracy. Reproducibility was assessed by comparing procedure results between two independent laboratories, and measurement uncertainty (MU) was evaluated in compliance with current guidelines.

Results: The established RMP exhibited high sensitivity, with a quantification range of 0.800-600 ng/mL (2.21-1,655 nmol/L), exceeding the ranges of existing JCTLM-listed RMPs. Intermediate precision was ≤2.6 %, and repeatability ranged from 0.9 to 1.9 % across all concentration levels. The relative mean bias ranged from -1.3 to 1.4 % for all matrices and concentration levels. Measurement uncertainties (MU) for cortisol in single measurements were ≤2.8 % regardless of the concentration level and sample type. Using the certified International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference panel, the equivalence between the candidate RMP and the Joint Committee on Traceability in Laboratory Medicine (JCTLM) listed RMPs (NRMeth 57 and NRMeth 8) was assessed, revealing excellent agreement.

Conclusions: This RMP allows for highly sensitive and reproducible determination of cortisol. The performance of the RMP facilitates the standardization of routine assays and ensures traceability in the measurement of individual patient samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical chemistry and laboratory medicine
Clinical chemistry and laboratory medicine 医学-医学实验技术
CiteScore
11.30
自引率
16.20%
发文量
306
审稿时长
3 months
期刊介绍: Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically. CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France). Topics: - clinical biochemistry - clinical genomics and molecular biology - clinical haematology and coagulation - clinical immunology and autoimmunity - clinical microbiology - drug monitoring and analysis - evaluation of diagnostic biomarkers - disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes) - new reagents, instrumentation and technologies - new methodologies - reference materials and methods - reference values and decision limits - quality and safety in laboratory medicine - translational laboratory medicine - clinical metrology Follow @cclm_degruyter on Twitter!
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信