{"title":"【低频超声在感染性胰腺坏死患者治疗中的应用】。","authors":"A M Zainutdinov, I S Malkov, A V Berdnikov","doi":"10.17116/hirurgia202502186","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To improve the treatment of patients with infected pancreatic necrosis by using non-contact ultrasound treatment of purulent-necrotic foci (NUST).</p><p><strong>Material and methods: </strong>We analyzed the results of treatment of 39 patients with infected pancreatic necrosis, admitted to the surgical department No. 2 of the City Clinical Hospital No. 7 in Kazan from 2017 to 2021. The central method of their surgical treatment was open draining operations combined with sequestrectomy. The study group consisted of 20 patients (4 women, 16 men) aged from 39 to 60 years (mean age - 49±9.5 years). In this group, the effectiveness of non-contact ultrasound treatment of purulent-necrotic foci using the SONOCA-185 apparatus was studied.</p><p><strong>Results: </strong>The application of ultrasound treatment of purulent foci of infected pancreatic necrosis in the study group allowed to increase their drainage effectiveness, which was reflected in the dynamics of reparative-proliferative process and relief of systemic inflammatory reaction. Wound healing occurred on the 7-9 day (on average, on the 7.6±2<sup>th</sup> day) without resuturing.</p><p><p>The pronounced bactericidal effect of low-frequency ultrasound and its phonophoretic effect are confirmed by the reduction of microbial content of wounds and cavities from 105 CFU and 104 CFU to 102 CFU after 3 sessions.</p><p><p>The sparing ultrasound sequestrectomy allows to remove only devitalized tissues, without causing destructions of the ductal system, vascular wall and hollow organs.</p><p><p>Ultrasound treatment of cavities in the study group resulted in a pronounced increase in transparency indicators and its approximation to reference solution, decreased peripheral blood leukocytosis, temperature reaction in patients on the 3<sup>rd</sup>, 7<sup>th</sup>, 12<sup>th</sup> days compared to the control group, where the temperature response is maintained at this time, and reduction in hospitalization duration on the 2.6±1 day in the study group of patients.</p>","PeriodicalId":35986,"journal":{"name":"Khirurgiya","volume":" 2","pages":"86-93"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[The use of low-frequency ultrasound in the treatment of patients with infected pancreatic necrosis].\",\"authors\":\"A M Zainutdinov, I S Malkov, A V Berdnikov\",\"doi\":\"10.17116/hirurgia202502186\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To improve the treatment of patients with infected pancreatic necrosis by using non-contact ultrasound treatment of purulent-necrotic foci (NUST).</p><p><strong>Material and methods: </strong>We analyzed the results of treatment of 39 patients with infected pancreatic necrosis, admitted to the surgical department No. 2 of the City Clinical Hospital No. 7 in Kazan from 2017 to 2021. The central method of their surgical treatment was open draining operations combined with sequestrectomy. The study group consisted of 20 patients (4 women, 16 men) aged from 39 to 60 years (mean age - 49±9.5 years). In this group, the effectiveness of non-contact ultrasound treatment of purulent-necrotic foci using the SONOCA-185 apparatus was studied.</p><p><strong>Results: </strong>The application of ultrasound treatment of purulent foci of infected pancreatic necrosis in the study group allowed to increase their drainage effectiveness, which was reflected in the dynamics of reparative-proliferative process and relief of systemic inflammatory reaction. Wound healing occurred on the 7-9 day (on average, on the 7.6±2<sup>th</sup> day) without resuturing.</p><p><p>The pronounced bactericidal effect of low-frequency ultrasound and its phonophoretic effect are confirmed by the reduction of microbial content of wounds and cavities from 105 CFU and 104 CFU to 102 CFU after 3 sessions.</p><p><p>The sparing ultrasound sequestrectomy allows to remove only devitalized tissues, without causing destructions of the ductal system, vascular wall and hollow organs.</p><p><p>Ultrasound treatment of cavities in the study group resulted in a pronounced increase in transparency indicators and its approximation to reference solution, decreased peripheral blood leukocytosis, temperature reaction in patients on the 3<sup>rd</sup>, 7<sup>th</sup>, 12<sup>th</sup> days compared to the control group, where the temperature response is maintained at this time, and reduction in hospitalization duration on the 2.6±1 day in the study group of patients.</p>\",\"PeriodicalId\":35986,\"journal\":{\"name\":\"Khirurgiya\",\"volume\":\" 2\",\"pages\":\"86-93\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Khirurgiya\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17116/hirurgia202502186\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Khirurgiya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/hirurgia202502186","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:提高非接触超声治疗脓坏死灶(NUST)对感染性胰腺坏死的治疗效果。材料与方法:对喀山市第七临床医院第二外科2017 - 2021年收治的39例感染性胰腺坏死患者的治疗结果进行分析。手术治疗的主要方法是开放引流术联合隔离切除术。研究组包括20例患者(女4例,男16例),年龄39 ~ 60岁(平均年龄- 49±9.5岁)。本组采用SONOCA-185仪器研究非接触超声治疗脓坏死灶的有效性。结果:研究组应用超声治疗感染性胰腺坏死化脓性灶,可提高引流效果,体现在修复-增殖过程的动力学和全身炎症反应的缓解。创面愈合时间为7 ~ 9天(平均7.6±2天),无缝合。3次治疗后,创面和空腔的微生物含量从105cfu和104cfu降至102cfu,证实了低频超声显著的杀菌作用及其声隐效应。保留超声分离切除术允许只切除失活组织,而不会造成导管系统、血管壁和空心器官的破坏。研究组对空腔进行超声治疗后,透明度指标及其与参考溶液的近似明显增加,外周血白细胞减少,患者在第3、7、12天的温度反应与对照组相比,此时温度反应保持不变,研究组患者住院时间缩短,为2.6±1天。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[The use of low-frequency ultrasound in the treatment of patients with infected pancreatic necrosis].

Objective: To improve the treatment of patients with infected pancreatic necrosis by using non-contact ultrasound treatment of purulent-necrotic foci (NUST).

Material and methods: We analyzed the results of treatment of 39 patients with infected pancreatic necrosis, admitted to the surgical department No. 2 of the City Clinical Hospital No. 7 in Kazan from 2017 to 2021. The central method of their surgical treatment was open draining operations combined with sequestrectomy. The study group consisted of 20 patients (4 women, 16 men) aged from 39 to 60 years (mean age - 49±9.5 years). In this group, the effectiveness of non-contact ultrasound treatment of purulent-necrotic foci using the SONOCA-185 apparatus was studied.

Results: The application of ultrasound treatment of purulent foci of infected pancreatic necrosis in the study group allowed to increase their drainage effectiveness, which was reflected in the dynamics of reparative-proliferative process and relief of systemic inflammatory reaction. Wound healing occurred on the 7-9 day (on average, on the 7.6±2th day) without resuturing.

The pronounced bactericidal effect of low-frequency ultrasound and its phonophoretic effect are confirmed by the reduction of microbial content of wounds and cavities from 105 CFU and 104 CFU to 102 CFU after 3 sessions.

The sparing ultrasound sequestrectomy allows to remove only devitalized tissues, without causing destructions of the ductal system, vascular wall and hollow organs.

Ultrasound treatment of cavities in the study group resulted in a pronounced increase in transparency indicators and its approximation to reference solution, decreased peripheral blood leukocytosis, temperature reaction in patients on the 3rd, 7th, 12th days compared to the control group, where the temperature response is maintained at this time, and reduction in hospitalization duration on the 2.6±1 day in the study group of patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Khirurgiya
Khirurgiya Medicine-Medicine (all)
CiteScore
0.70
自引率
0.00%
发文量
161
期刊介绍: Хирургия отдельных областей сердце, сосуды легкие пищевод молочная железа желудок и двенадцатиперстная кишка кишечник желчевыводящие пути печень
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信