{"title":"体外膜氧合(ECMO)治疗期间的抗凝监测策略-同时获得凝血试验的差异:一项回顾性单中心队列研究","authors":"Alexander C Reisinger, Nikolaus Schneider, Marco Koellinger, Stefan Hatzl, Gerald Hackl, Reinhard Raggam, Dirk von Lewinski, Florian Posch, Philipp Eller","doi":"10.1177/08850666241313357","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>During extracorporeal membrane oxygenation (ECMO) systemic anticoagulation with unfractionated heparin (UFH) is standard-of-care. However, there is uncertainty regarding optimal anticoagulation monitoring strategies.</p><p><strong>Methods: </strong>We retrospectively investigated venovenous and venoarterial ECMO patients at the medical ICUs at the Medical University of Graz, Austria. We analyzed the correlation and concordance of R-time in thromboelastography (TEG), activated partial thromboplastin time (aPTT), and anti-Xa activity. The proportion within target range, the association of coagulation parameters above or below target range (aPTT 54-72 s; equals 1.5-2× upper limit of normal (ULN), anti-Xa activity 0.2-0.5 U/mL, and R-time in assays without heparinase 675-900 s; equals 1.5-2× ULN) with mortality, bleeding events and thrombotic complications were investigated.</p><p><strong>Results: </strong>We analyzed 671 clusters of simultaneously performed coagulation tests in 85 ECMO cases that fulfilled inclusion criteria. Median age of patients was 57 years and 32% were female. There were poor correlations between the three coagulation tests and the proportion of discordance was 46%. Within the target range were 21% of R-time, 15% of aPTT, and 44% of anti-Xa activity measurements. Singular and multiple bleeding events occurred in 25 and 32 patients, respectively. The most common bleeding locations were catheter and cannula insertion sites followed by pulmonary hemorrhage. In VA-ECMO, anti-Xa activity was associated (OR 1.03 [1.01-1.06], p = 0.005) and correlated with bleeding events (spearman rho 0.49, p = 0.002; point biserial 0.49, p = 0.001). aPTT level below target range was associated with reduced mortality (OR 0.98 [0.97-0.99], p = 0.024). Thrombotic events occurred in six patients with no association of coagulation tests.</p><p><strong>Conclusion: </strong>There was a high rate of discordance and poor correlation between aPTT, anti-Xa activity and R-time in TEG in ECMO patients. We found high rates of bleeding events and in VA-ECMO an association with elevated anti-Xa activity levels.</p>","PeriodicalId":16307,"journal":{"name":"Journal of Intensive Care Medicine","volume":" ","pages":"8850666241313357"},"PeriodicalIF":3.0000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Anticoagulation Monitoring Strategies During Extracorporeal Membrane Oxygenation (ECMO) Therapy - Differences Between Simultaneously Obtained Coagulation Tests: A Retrospective Single-Center Cohort Study.\",\"authors\":\"Alexander C Reisinger, Nikolaus Schneider, Marco Koellinger, Stefan Hatzl, Gerald Hackl, Reinhard Raggam, Dirk von Lewinski, Florian Posch, Philipp Eller\",\"doi\":\"10.1177/08850666241313357\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>During extracorporeal membrane oxygenation (ECMO) systemic anticoagulation with unfractionated heparin (UFH) is standard-of-care. However, there is uncertainty regarding optimal anticoagulation monitoring strategies.</p><p><strong>Methods: </strong>We retrospectively investigated venovenous and venoarterial ECMO patients at the medical ICUs at the Medical University of Graz, Austria. We analyzed the correlation and concordance of R-time in thromboelastography (TEG), activated partial thromboplastin time (aPTT), and anti-Xa activity. The proportion within target range, the association of coagulation parameters above or below target range (aPTT 54-72 s; equals 1.5-2× upper limit of normal (ULN), anti-Xa activity 0.2-0.5 U/mL, and R-time in assays without heparinase 675-900 s; equals 1.5-2× ULN) with mortality, bleeding events and thrombotic complications were investigated.</p><p><strong>Results: </strong>We analyzed 671 clusters of simultaneously performed coagulation tests in 85 ECMO cases that fulfilled inclusion criteria. Median age of patients was 57 years and 32% were female. There were poor correlations between the three coagulation tests and the proportion of discordance was 46%. Within the target range were 21% of R-time, 15% of aPTT, and 44% of anti-Xa activity measurements. Singular and multiple bleeding events occurred in 25 and 32 patients, respectively. The most common bleeding locations were catheter and cannula insertion sites followed by pulmonary hemorrhage. In VA-ECMO, anti-Xa activity was associated (OR 1.03 [1.01-1.06], p = 0.005) and correlated with bleeding events (spearman rho 0.49, p = 0.002; point biserial 0.49, p = 0.001). aPTT level below target range was associated with reduced mortality (OR 0.98 [0.97-0.99], p = 0.024). Thrombotic events occurred in six patients with no association of coagulation tests.</p><p><strong>Conclusion: </strong>There was a high rate of discordance and poor correlation between aPTT, anti-Xa activity and R-time in TEG in ECMO patients. We found high rates of bleeding events and in VA-ECMO an association with elevated anti-Xa activity levels.</p>\",\"PeriodicalId\":16307,\"journal\":{\"name\":\"Journal of Intensive Care Medicine\",\"volume\":\" \",\"pages\":\"8850666241313357\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-02-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Intensive Care Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/08850666241313357\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Intensive Care Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08850666241313357","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

简介:在体外膜氧合(ECMO)期间,系统抗凝与未分离肝素(UFH)是标准的护理。然而,关于最佳抗凝监测策略存在不确定性。方法:我们回顾性调查了奥地利格拉茨医科大学icu的静脉静脉和静脉动脉ECMO患者。我们分析了血栓弹性成像r时间(TEG)、活化部分凝血活素时间(aPTT)和抗xa活性的相关性和一致性。目标范围内的比例、凝血参数高于或低于目标范围的关联关系(aPTT 54 ~ 72 s;在不含肝素酶675-900 s的情况下,正常(ULN)上限1.5-2倍,抗xa活性0.2-0.5 U/mL, R-time;等于1.5-2倍ULN),死亡率,出血事件和血栓并发症的调查。结果:我们分析了85例符合纳入标准的ECMO病例中同时进行凝血试验的671组。患者中位年龄为57岁,32%为女性。三项凝血检测结果相关性较差,不一致率为46%。在目标范围内,有21%的R-time, 15%的aPTT和44%的抗xa活性测量值。单独出血25例,多发出血32例。最常见的出血部位是导管和套管插入部位,其次是肺出血。在VA-ECMO中,抗xa活性与出血事件相关(OR 1.03 [1.01-1.06], p = 0.005),且与出血事件相关(spearman rho 0.49, p = 0.002;点双列0.49,p = 0.001)。aPTT水平低于目标范围与死亡率降低相关(OR 0.98 [0.97-0.99], p = 0.024)。6例患者发生血栓事件,与凝血试验无关。结论:ECMO患者TEG中aPTT、抗xa活性与R-time的不一致性较高,相关性较差。我们发现VA-ECMO中高出血事件发生率与抗xa活性水平升高有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Anticoagulation Monitoring Strategies During Extracorporeal Membrane Oxygenation (ECMO) Therapy - Differences Between Simultaneously Obtained Coagulation Tests: A Retrospective Single-Center Cohort Study.

Introduction: During extracorporeal membrane oxygenation (ECMO) systemic anticoagulation with unfractionated heparin (UFH) is standard-of-care. However, there is uncertainty regarding optimal anticoagulation monitoring strategies.

Methods: We retrospectively investigated venovenous and venoarterial ECMO patients at the medical ICUs at the Medical University of Graz, Austria. We analyzed the correlation and concordance of R-time in thromboelastography (TEG), activated partial thromboplastin time (aPTT), and anti-Xa activity. The proportion within target range, the association of coagulation parameters above or below target range (aPTT 54-72 s; equals 1.5-2× upper limit of normal (ULN), anti-Xa activity 0.2-0.5 U/mL, and R-time in assays without heparinase 675-900 s; equals 1.5-2× ULN) with mortality, bleeding events and thrombotic complications were investigated.

Results: We analyzed 671 clusters of simultaneously performed coagulation tests in 85 ECMO cases that fulfilled inclusion criteria. Median age of patients was 57 years and 32% were female. There were poor correlations between the three coagulation tests and the proportion of discordance was 46%. Within the target range were 21% of R-time, 15% of aPTT, and 44% of anti-Xa activity measurements. Singular and multiple bleeding events occurred in 25 and 32 patients, respectively. The most common bleeding locations were catheter and cannula insertion sites followed by pulmonary hemorrhage. In VA-ECMO, anti-Xa activity was associated (OR 1.03 [1.01-1.06], p = 0.005) and correlated with bleeding events (spearman rho 0.49, p = 0.002; point biserial 0.49, p = 0.001). aPTT level below target range was associated with reduced mortality (OR 0.98 [0.97-0.99], p = 0.024). Thrombotic events occurred in six patients with no association of coagulation tests.

Conclusion: There was a high rate of discordance and poor correlation between aPTT, anti-Xa activity and R-time in TEG in ECMO patients. We found high rates of bleeding events and in VA-ECMO an association with elevated anti-Xa activity levels.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Intensive Care Medicine
Journal of Intensive Care Medicine CRITICAL CARE MEDICINE-
CiteScore
7.60
自引率
3.20%
发文量
107
期刊介绍: Journal of Intensive Care Medicine (JIC) is a peer-reviewed bi-monthly journal offering medical and surgical clinicians in adult and pediatric intensive care state-of-the-art, broad-based analytic reviews and updates, original articles, reports of large clinical series, techniques and procedures, topic-specific electronic resources, book reviews, and editorials on all aspects of intensive/critical/coronary care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信