GEM信号和时间分辨率的数值分析

IF 2.1 4区 物理与天体物理 Q2 PHYSICS, MULTIDISCIPLINARY
Pramana Pub Date : 2025-01-30 DOI:10.1007/s12043-024-02859-3
S Swain, S K Sahu, P K Sahu
{"title":"GEM信号和时间分辨率的数值分析","authors":"S Swain,&nbsp;S K Sahu,&nbsp;P K Sahu","doi":"10.1007/s12043-024-02859-3","DOIUrl":null,"url":null,"abstract":"<div><p>We have investigated the gas electron multiplier (GEM) signal and time resolution using a numerical analysis method. The Garfield<span>\\(++\\)</span> simulation package with a known field solver, ANSYS, is used here. To examine the impacts of gas mixture and electron transport characteristics inside the detector, two other softwares, Magboltz and Heed, were utilised. By exploring the effects of detector geometry, electric fields, incoming particle energy and gas mixture characteristics, we tried improving GEM detectors for higher temporal resolution. A single GEM detector was investigated with two radiation sources, i.e., a 5.9 keV <span>\\(\\hbox {Fe}^{55}\\)</span> X-ray photon and cosmic muons with energies ranging from 1 MeV to 1 TeV. With Ar:<span>\\(\\hbox {CO}_2\\)</span> gas mixture for a particular set-up, a minimum time resolution of up to around 4 ns was recorded. This number can be reduced even more by using various detector geometries and field settings. A significant result in lowering the temporal resolution was achieved by changing the drift field and percentage of the ionisation component in the gas mixture. The admixture of <span>\\(\\hbox {O}_2\\)</span> and <span>\\(\\hbox {N}_2\\)</span> in the gas medium also improved the detector time performance. It was also observed that the initial particle energy has little effect on the timing accuracy of the detector.\n</p></div>","PeriodicalId":743,"journal":{"name":"Pramana","volume":"99 1","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical analysis for GEM signal and time resolution\",\"authors\":\"S Swain,&nbsp;S K Sahu,&nbsp;P K Sahu\",\"doi\":\"10.1007/s12043-024-02859-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>We have investigated the gas electron multiplier (GEM) signal and time resolution using a numerical analysis method. The Garfield<span>\\\\(++\\\\)</span> simulation package with a known field solver, ANSYS, is used here. To examine the impacts of gas mixture and electron transport characteristics inside the detector, two other softwares, Magboltz and Heed, were utilised. By exploring the effects of detector geometry, electric fields, incoming particle energy and gas mixture characteristics, we tried improving GEM detectors for higher temporal resolution. A single GEM detector was investigated with two radiation sources, i.e., a 5.9 keV <span>\\\\(\\\\hbox {Fe}^{55}\\\\)</span> X-ray photon and cosmic muons with energies ranging from 1 MeV to 1 TeV. With Ar:<span>\\\\(\\\\hbox {CO}_2\\\\)</span> gas mixture for a particular set-up, a minimum time resolution of up to around 4 ns was recorded. This number can be reduced even more by using various detector geometries and field settings. A significant result in lowering the temporal resolution was achieved by changing the drift field and percentage of the ionisation component in the gas mixture. The admixture of <span>\\\\(\\\\hbox {O}_2\\\\)</span> and <span>\\\\(\\\\hbox {N}_2\\\\)</span> in the gas medium also improved the detector time performance. It was also observed that the initial particle energy has little effect on the timing accuracy of the detector.\\n</p></div>\",\"PeriodicalId\":743,\"journal\":{\"name\":\"Pramana\",\"volume\":\"99 1\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-01-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pramana\",\"FirstCategoryId\":\"4\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s12043-024-02859-3\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PHYSICS, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pramana","FirstCategoryId":"4","ListUrlMain":"https://link.springer.com/article/10.1007/s12043-024-02859-3","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

本文用数值分析方法研究了气电子倍增器(GEM)的信号和时间分辨率。这里使用的是加菲猫\(++\)仿真包和已知的场求解器ANSYS。为了检查气体混合物和探测器内部电子传输特性的影响,使用了另外两个软件Magboltz和Heed。通过探索探测器几何形状、电场、入射粒子能量和气体混合特性的影响,我们尝试改进GEM探测器以获得更高的时间分辨率。利用5.9 keV \(\hbox {Fe}^{55}\) x射线光子和1 MeV ~ 1 TeV宇宙介子两种辐射源对单个GEM探测器进行了研究。使用Ar: \(\hbox {CO}_2\)气体混合物进行特定设置,记录的最小时间分辨率可达约4 ns。这个数字可以通过使用各种探测器的几何形状和现场设置来进一步减少。通过改变漂移场和气体混合物中电离成分的百分比,在降低时间分辨率方面取得了显著的结果。在气体介质中掺入\(\hbox {O}_2\)和\(\hbox {N}_2\)也提高了探测器的时间性能。实验还发现,初始粒子能量对探测器的定时精度影响不大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Numerical analysis for GEM signal and time resolution

We have investigated the gas electron multiplier (GEM) signal and time resolution using a numerical analysis method. The Garfield\(++\) simulation package with a known field solver, ANSYS, is used here. To examine the impacts of gas mixture and electron transport characteristics inside the detector, two other softwares, Magboltz and Heed, were utilised. By exploring the effects of detector geometry, electric fields, incoming particle energy and gas mixture characteristics, we tried improving GEM detectors for higher temporal resolution. A single GEM detector was investigated with two radiation sources, i.e., a 5.9 keV \(\hbox {Fe}^{55}\) X-ray photon and cosmic muons with energies ranging from 1 MeV to 1 TeV. With Ar:\(\hbox {CO}_2\) gas mixture for a particular set-up, a minimum time resolution of up to around 4 ns was recorded. This number can be reduced even more by using various detector geometries and field settings. A significant result in lowering the temporal resolution was achieved by changing the drift field and percentage of the ionisation component in the gas mixture. The admixture of \(\hbox {O}_2\) and \(\hbox {N}_2\) in the gas medium also improved the detector time performance. It was also observed that the initial particle energy has little effect on the timing accuracy of the detector.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pramana
Pramana 物理-物理:综合
CiteScore
3.60
自引率
7.10%
发文量
206
审稿时长
3 months
期刊介绍: Pramana - Journal of Physics is a monthly research journal in English published by the Indian Academy of Sciences in collaboration with Indian National Science Academy and Indian Physics Association. The journal publishes refereed papers covering current research in Physics, both original contributions - research papers, brief reports or rapid communications - and invited reviews. Pramana also publishes special issues devoted to advances in specific areas of Physics and proceedings of select high quality conferences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信