微针阵列技术在重金属检测中的应用进展。

IF 3.2 4区 医学 Q1 Pharmacology, Toxicology and Pharmaceutics
Robert M Taylor, Abdul-Mehdi S Ali, Yiliang Zhu, Alicia M Bolt, Justin T Baca
{"title":"微针阵列技术在重金属检测中的应用进展。","authors":"Robert M Taylor, Abdul-Mehdi S Ali, Yiliang Zhu, Alicia M Bolt, Justin T Baca","doi":"10.1080/15376516.2025.2461647","DOIUrl":null,"url":null,"abstract":"<p><p>Heavy metal and metalloid (HM) exposure poses significant health risks, including cardiovascular disease, cancer, and renal damage. This contamination, prevalent in the Western US, involves arsenic (As), cadmium (Cd), uranium (U), and vanadium (V). Interstitial fluid (ISF) is a source of biomarkers, which can be minimally invasively collected using microneedle array (MA) technology. Our study hypothesized that MA-extracted ISF would facilitate noninvasive HM quantification. We established analytical parameters for HM detection in ISF using inductively coupled plasma-mass spectrometry (ICP-MS), defined baseline ISF HM concentrations in unexposed animal populations, and monitored HM levels in ISF under mixed exposure in animal models. Additionally, we assessed HM levels in ISF and biological fluids from three human subjects. Thirty-six Sprague-Dawley rats were divided into cohorts: low-level mixed HMs exposure (5X maximum contaminant level (MCL)); high-level single HM with low-level others (50X MCL for one HM with 5X for others); and unexposed controls. ISF and plasma were collected weekly for 8 weeks and analyzed <i>via</i> ICP-MS. Our findings reveal a correlation between ISF and plasma HM levels, underscoring ISF's potential for real-time monitoring of HM exposure. This study also establishes baseline ISF HM levels, illustrating the feasibility of HM quantification using small ISF volumes.</p>","PeriodicalId":23177,"journal":{"name":"Toxicology Mechanisms and Methods","volume":" ","pages":"1-11"},"PeriodicalIF":3.2000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advancements in heavy metal detection using microneedle array technology.\",\"authors\":\"Robert M Taylor, Abdul-Mehdi S Ali, Yiliang Zhu, Alicia M Bolt, Justin T Baca\",\"doi\":\"10.1080/15376516.2025.2461647\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Heavy metal and metalloid (HM) exposure poses significant health risks, including cardiovascular disease, cancer, and renal damage. This contamination, prevalent in the Western US, involves arsenic (As), cadmium (Cd), uranium (U), and vanadium (V). Interstitial fluid (ISF) is a source of biomarkers, which can be minimally invasively collected using microneedle array (MA) technology. Our study hypothesized that MA-extracted ISF would facilitate noninvasive HM quantification. We established analytical parameters for HM detection in ISF using inductively coupled plasma-mass spectrometry (ICP-MS), defined baseline ISF HM concentrations in unexposed animal populations, and monitored HM levels in ISF under mixed exposure in animal models. Additionally, we assessed HM levels in ISF and biological fluids from three human subjects. Thirty-six Sprague-Dawley rats were divided into cohorts: low-level mixed HMs exposure (5X maximum contaminant level (MCL)); high-level single HM with low-level others (50X MCL for one HM with 5X for others); and unexposed controls. ISF and plasma were collected weekly for 8 weeks and analyzed <i>via</i> ICP-MS. Our findings reveal a correlation between ISF and plasma HM levels, underscoring ISF's potential for real-time monitoring of HM exposure. This study also establishes baseline ISF HM levels, illustrating the feasibility of HM quantification using small ISF volumes.</p>\",\"PeriodicalId\":23177,\"journal\":{\"name\":\"Toxicology Mechanisms and Methods\",\"volume\":\" \",\"pages\":\"1-11\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Toxicology Mechanisms and Methods\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/15376516.2025.2461647\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Pharmacology, Toxicology and Pharmaceutics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Toxicology Mechanisms and Methods","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/15376516.2025.2461647","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

摘要

重金属和类金属(HM)暴露会造成严重的健康风险,包括心血管疾病、癌症和肾脏损害。这种污染在美国西部普遍存在,涉及砷(As)、镉(Cd)、铀(U)和钒(V)。间质液(ISF)是生物标志物的来源,可以使用微针阵列(MA)技术进行微创收集。我们的研究假设ma提取的ISF可以促进非侵入性HM定量。我们利用电感耦合等离子体质谱(ICP-MS)建立了ISF中HM检测的分析参数,定义了未暴露动物种群中ISF HM的基线浓度,并在动物模型中监测了混合暴露下ISF中的HM水平。此外,我们评估了三名受试者ISF和生物体液中的HM水平。36只Sprague Dawley大鼠分为两组:低水平混合HMs暴露(5倍最大污染物水平(MCL));高水平单个HM与低水平其他HM(一个HM 50倍MCL,其他5倍MCL);和未暴露的控制。每周采集ISF和血浆,持续8周,并通过ICP-MS进行分析。我们的研究结果揭示了ISF与血浆HM水平之间的相关性,强调了ISF在实时监测HM暴露方面的潜力。本研究还建立了基线ISF HM水平,说明了使用小ISF体积量化HM的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Advancements in heavy metal detection using microneedle array technology.

Heavy metal and metalloid (HM) exposure poses significant health risks, including cardiovascular disease, cancer, and renal damage. This contamination, prevalent in the Western US, involves arsenic (As), cadmium (Cd), uranium (U), and vanadium (V). Interstitial fluid (ISF) is a source of biomarkers, which can be minimally invasively collected using microneedle array (MA) technology. Our study hypothesized that MA-extracted ISF would facilitate noninvasive HM quantification. We established analytical parameters for HM detection in ISF using inductively coupled plasma-mass spectrometry (ICP-MS), defined baseline ISF HM concentrations in unexposed animal populations, and monitored HM levels in ISF under mixed exposure in animal models. Additionally, we assessed HM levels in ISF and biological fluids from three human subjects. Thirty-six Sprague-Dawley rats were divided into cohorts: low-level mixed HMs exposure (5X maximum contaminant level (MCL)); high-level single HM with low-level others (50X MCL for one HM with 5X for others); and unexposed controls. ISF and plasma were collected weekly for 8 weeks and analyzed via ICP-MS. Our findings reveal a correlation between ISF and plasma HM levels, underscoring ISF's potential for real-time monitoring of HM exposure. This study also establishes baseline ISF HM levels, illustrating the feasibility of HM quantification using small ISF volumes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.60
自引率
3.10%
发文量
66
审稿时长
6-12 weeks
期刊介绍: Toxicology Mechanisms and Methods is a peer-reviewed journal whose aim is twofold. Firstly, the journal contains original research on subjects dealing with the mechanisms by which foreign chemicals cause toxic tissue injury. Chemical substances of interest include industrial compounds, environmental pollutants, hazardous wastes, drugs, pesticides, and chemical warfare agents. The scope of the journal spans from molecular and cellular mechanisms of action to the consideration of mechanistic evidence in establishing regulatory policy. Secondly, the journal addresses aspects of the development, validation, and application of new and existing laboratory methods, techniques, and equipment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信