角膜塑形术对儿童近视角膜生物力学的短期影响,重点关注SPA1和应力应变指数(SSI)参数。

IF 1.1 4区 医学 Q3 OPHTHALMOLOGY
Arquivos brasileiros de oftalmologia Pub Date : 2025-01-27 eCollection Date: 2025-01-01 DOI:10.5935/0004-2749.2023-0356
Wenjuan Xie, Xue Li, Cheng Yang, Yingan Li, Xiyang Yang, Zheng Li, Yongyi Niu, Jin Zeng
{"title":"角膜塑形术对儿童近视角膜生物力学的短期影响,重点关注SPA1和应力应变指数(SSI)参数。","authors":"Wenjuan Xie, Xue Li, Cheng Yang, Yingan Li, Xiyang Yang, Zheng Li, Yongyi Niu, Jin Zeng","doi":"10.5935/0004-2749.2023-0356","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Although the orthokeratology effects on corneal biomechanics have been proven with clinical trials, reports of stiffness parameter change are scarce. This study investigated the short-term orthokeratology effects in pediatric myopia and compared stiffness parameter changes to those published in recent clinical investigations. This prospective study aimed to investigate corneal biomechanics changes induced by short-term overnight orthokeratology treatment, focusing on stiffness parameter at A1 and stress-strain index.</p><p><strong>Methods: </strong>Twenty-six children aged 8 to 18 were included in this study using orthokeratology lenses for two different durations: 1 day and 1 week. Corneal biomechanics were assessed using corneal visualization (Corvis) Scheimpflug technology. Measurements were taken at baseline and after each wearing session. Changes in corneal stiffness parameters and corneal curvature were analyzed.</p><p><strong>Results: </strong>All parameters changed significantly after 1 week of lens wear (p<0.05), except for velocity of corneal apex at the first and second applanation times highest concavity time, radius, stiffness parameter at A1 and stress-strain index. After 1 day, central corneal thickness, first applanation time, second applanation time, deformation amplitude ratio (2 mm), and Corvis biomechanical index (CBI) remained stable (p>0.05). After 1 week, central corneal thickness and first applanation time decreased, whereas second applanation time, deformation amplitude ratio, and Corvis Biomechanical Index significantly increased. With intraocular pressure and central corneal thickness as control variables, no significant correlation was found between stress-strain index and curvature changes (p>0.05). With age as the control variable, no significant correlation was found between stress-strain index and curvature changes (p>0.05).</p><p><strong>Conclusions: </strong>Short-term orthokeratology treatment induced notable changes in several corneal biomechanical parameters. Stiffness parameter at A1 and stress-strain index are unaffected by increasing lens wear duration and do not influence the orthokeratology effect.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 4","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Short-term orthokeratology effects on corneal biomechanics with a focus on SPA1 and stress-strain index (SSI) parameters in pediatric myopia.\",\"authors\":\"Wenjuan Xie, Xue Li, Cheng Yang, Yingan Li, Xiyang Yang, Zheng Li, Yongyi Niu, Jin Zeng\",\"doi\":\"10.5935/0004-2749.2023-0356\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Although the orthokeratology effects on corneal biomechanics have been proven with clinical trials, reports of stiffness parameter change are scarce. This study investigated the short-term orthokeratology effects in pediatric myopia and compared stiffness parameter changes to those published in recent clinical investigations. This prospective study aimed to investigate corneal biomechanics changes induced by short-term overnight orthokeratology treatment, focusing on stiffness parameter at A1 and stress-strain index.</p><p><strong>Methods: </strong>Twenty-six children aged 8 to 18 were included in this study using orthokeratology lenses for two different durations: 1 day and 1 week. Corneal biomechanics were assessed using corneal visualization (Corvis) Scheimpflug technology. Measurements were taken at baseline and after each wearing session. Changes in corneal stiffness parameters and corneal curvature were analyzed.</p><p><strong>Results: </strong>All parameters changed significantly after 1 week of lens wear (p<0.05), except for velocity of corneal apex at the first and second applanation times highest concavity time, radius, stiffness parameter at A1 and stress-strain index. After 1 day, central corneal thickness, first applanation time, second applanation time, deformation amplitude ratio (2 mm), and Corvis biomechanical index (CBI) remained stable (p>0.05). After 1 week, central corneal thickness and first applanation time decreased, whereas second applanation time, deformation amplitude ratio, and Corvis Biomechanical Index significantly increased. With intraocular pressure and central corneal thickness as control variables, no significant correlation was found between stress-strain index and curvature changes (p>0.05). With age as the control variable, no significant correlation was found between stress-strain index and curvature changes (p>0.05).</p><p><strong>Conclusions: </strong>Short-term orthokeratology treatment induced notable changes in several corneal biomechanical parameters. Stiffness parameter at A1 and stress-strain index are unaffected by increasing lens wear duration and do not influence the orthokeratology effect.</p>\",\"PeriodicalId\":8397,\"journal\":{\"name\":\"Arquivos brasileiros de oftalmologia\",\"volume\":\"88 4\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-01-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arquivos brasileiros de oftalmologia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5935/0004-2749.2023-0356\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arquivos brasileiros de oftalmologia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5935/0004-2749.2023-0356","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:虽然角膜塑形术对角膜生物力学的影响已经通过临床试验得到证实,但关于角膜硬度参数变化的报道很少。本研究调查了角膜塑形术对儿童近视的短期影响,并将僵硬参数的变化与最近发表的临床研究结果进行了比较。本前瞻性研究旨在探讨短期过夜角膜塑形术治疗引起的角膜生物力学变化,重点关注A1级刚度参数和应力-应变指数。方法:选取26名年龄在8 ~ 18岁的儿童,分别使用角膜塑形镜1天和1周。采用角膜可视化(Corvis) Scheimpflug技术评估角膜生物力学。在基线和每次佩戴后进行测量。分析了角膜刚度参数和角膜曲率的变化。结果:晶状体佩戴1周后各项参数变化显著(p0.05)。1周后,角膜中央厚度和第一次压平时间减少,第二次压平时间、变形幅度比和Corvis生物力学指数显著增加。以眼压和角膜中央厚度为对照变量,应力应变指数与角膜曲率变化无显著相关性(p < 0.05)。以年龄为控制变量,应力-应变指数与曲率变化无显著相关(p < 0.05)。结论:短期角膜塑形术治疗可引起角膜若干生物力学参数的显著改变。A1的刚度参数和应力应变指数不受晶状体磨损时间增加的影响,也不影响角膜塑形效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Short-term orthokeratology effects on corneal biomechanics with a focus on SPA1 and stress-strain index (SSI) parameters in pediatric myopia.

Purpose: Although the orthokeratology effects on corneal biomechanics have been proven with clinical trials, reports of stiffness parameter change are scarce. This study investigated the short-term orthokeratology effects in pediatric myopia and compared stiffness parameter changes to those published in recent clinical investigations. This prospective study aimed to investigate corneal biomechanics changes induced by short-term overnight orthokeratology treatment, focusing on stiffness parameter at A1 and stress-strain index.

Methods: Twenty-six children aged 8 to 18 were included in this study using orthokeratology lenses for two different durations: 1 day and 1 week. Corneal biomechanics were assessed using corneal visualization (Corvis) Scheimpflug technology. Measurements were taken at baseline and after each wearing session. Changes in corneal stiffness parameters and corneal curvature were analyzed.

Results: All parameters changed significantly after 1 week of lens wear (p<0.05), except for velocity of corneal apex at the first and second applanation times highest concavity time, radius, stiffness parameter at A1 and stress-strain index. After 1 day, central corneal thickness, first applanation time, second applanation time, deformation amplitude ratio (2 mm), and Corvis biomechanical index (CBI) remained stable (p>0.05). After 1 week, central corneal thickness and first applanation time decreased, whereas second applanation time, deformation amplitude ratio, and Corvis Biomechanical Index significantly increased. With intraocular pressure and central corneal thickness as control variables, no significant correlation was found between stress-strain index and curvature changes (p>0.05). With age as the control variable, no significant correlation was found between stress-strain index and curvature changes (p>0.05).

Conclusions: Short-term orthokeratology treatment induced notable changes in several corneal biomechanical parameters. Stiffness parameter at A1 and stress-strain index are unaffected by increasing lens wear duration and do not influence the orthokeratology effect.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.60
自引率
0.00%
发文量
200
审稿时长
6-12 weeks
期刊介绍: The ABO-ARQUIVOS BRASILEIROS DE OFTALMOLOGIA (ABO, ISSN 0004-2749 - print and ISSN 1678-2925 - (ABO, ISSN 0004-2749 - print and ISSN 1678-2925 - electronic version), the official bimonthly publication of the Brazilian Council of Ophthalmology (CBO), aims to disseminate scientific studies in Ophthalmology, Visual Science and Health public, by promoting research, improvement and updating of professionals related to the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信